A complication of an axillary intra-aortic balloon pump

被引:0
|
作者
Kodack, Eileen [1 ]
Patel, Riya [2 ]
Bonner, Carain [1 ]
Pantin, Enrique [1 ]
机构
[1] Univ Med & Dent New Jersey, Dept Anesthesiol & Perioperat Med, New Brunswick, NJ 08901 USA
[2] Rutgers State Univ, Robert Wood Johnson Med Sch, New Brunswick, NJ 08901 USA
来源
JOURNAL OF SURGICAL CASE REPORTS | 2024年 / 2024卷 / 03期
关键词
intra-aortic balloon pump (IABP); intra-aortic balloon pump complication; intra-aortic balloon pump malposition; ascending aorta mass; descending aorta; transesophageal echo; BRIDGE;
D O I
10.1093/jscr/rjae092
中图分类号
R61 [外科手术学];
学科分类号
摘要
Intra-aortic balloon pumps (IABPs) are used to mechanically temporize a failing heart by decreasing afterload while increasing coronary perfusion pressure of the heart while more definitive treatment is sought. We report a case of a 65-year-old male with nonischemic cardiomyopathy, atrial fibrillation, thyroiditis, and non-Hodgkin lymphoma who presented with worsening heart failure. He underwent a percutaneous placement of a left axillary IABP with seemingly no complications. Approximately 3 weeks post-placement, the patient was taken for a heart transplant when an intraoperative transesophageal echo showed that the IABP was in the aortic arch and ascending aorta, instead of its proper placement in the descending aorta. The patient's arterial line showed waveforms appropriate for an IABP patient, and the patient showed no signs indicative of improper placement. This erroneous placement carried the potential to affect the aortic valve function, injure the aortic intima and/or occlude the aortic arch vessels. .
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Mathematical modelling of intra-aortic balloon pump
    Abdolrazaghi, Mona
    Navidbakhsh, Mahdi
    Hassani, Kamran
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (05) : 567 - 576
  • [32] INTRA-AORTIC BALLOON ASSISTANCE WITHOUT A PUMP
    SIDERIS, DA
    NANAS, JN
    CHRYSOS, DN
    MOULOPOULOS, SD
    EUROPEAN HEART JOURNAL, 1983, 4 (08) : 536 - 546
  • [33] Intra-aortic balloon pump: is the tide turning?
    Gelsomino, Sandro
    Johnson, Daniel M.
    Lorusso, Roberto
    CRITICAL CARE, 2018, 22
  • [34] Usefulness of Intra-aortic Balloon Pump Counterpulsation
    van Nunen, Lokien X.
    Noc, Marko
    Kapur, Navin K.
    Patel, Manesh R.
    Perera, Divaka
    Pijls, Nico H. J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (03): : 469 - 476
  • [35] Intra-aortic balloon pump in heart surgery
    Engin, Mesut
    Onur, Tugba
    Onur, Anil
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2024, 72 (06) : 426 - 427
  • [36] Acute Left Subclavian Artery - Aortic Arch Approach Angle Increases the Risk of Axillary Intra-Aortic Balloon Pump Complication: A Word of Caution
    Ashraf, H. M.
    Massoomi, M.
    Mustafa, A.
    Vilaro, J.
    Parker, A.
    Aranda, J.
    Jeng, E.
    Bleiweis, M.
    Kerensky, R.
    Al-Ani, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S232 - S232
  • [37] von Willebrand factor and bleeding complication in patients treated with intra-aortic balloon pump
    Zhong, Hua
    Zhu, Zhaowei
    Tang, Jianjun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 214 : 483 - 483
  • [38] Failure to record delirium as a complication of intra-aortic balloon pump treatment: A retrospective study
    Glick, REL
    Sanders, KM
    Stern, TA
    JOURNAL OF GERIATRIC PSYCHIATRY AND NEUROLOGY, 1996, 9 (02) : 97 - 99
  • [39] Intra-aortic balloon pump microperforation resulting in balloon entrapment
    Warrillow, S. J.
    Fealy, N. G.
    Houston, S. A.
    ANAESTHESIA AND INTENSIVE CARE, 2008, 36 (06) : 916 - 917
  • [40] SPLENIC INFARCTION - COMPLICATION OF INTRA-AORTIC BALLOON COUNTERPULSATION
    BUSCH, HM
    COGBILL, TH
    GUNDERSEN, AE
    AMERICAN HEART JOURNAL, 1985, 109 (02) : 383 - 385