LONG-TERM ANALYSIS OF INTRASCLERAL FIXATION OF INTRAOCULAR LENS Trocar-Cannula-Based Sutureless Intrascleral Fixation Versus Sutured Scleral Fixation

被引:5
|
作者
Byun, Zeeyoon [1 ]
Kim, Dong I. K. [1 ]
Kong, Mingui [1 ,2 ]
机构
[1] HanGil Eye Hosp, Dept Ophthalmol, 35 Bupyeong Daero, Incheon 21388, South Korea
[2] Catholic Kwandong Univ, Dept Ophthalmol, Coll Med, Incheon, South Korea
关键词
sutureless scleral fixation; sutured scleral fixation; trocar-cannula-based technique; surgically induced astigmatism; SURGICALLY INDUCED ASTIGMATISM; COMBINED PHACOEMULSIFICATION; TRANSSCLERAL FIXATION; REFRACTIVE-OUTCOMES; VITRECTOMY; CAPTURE;
D O I
10.1097/IAE.0000000000003721
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To compare the long-term outcomes of sutureless intrascleral fixation of the intraocular lens versus sutured scleral fixation.Methods:The authors retrospectively analyzed the medical records of patients who underwent intrascleral fixation of the intraocular lens using two different techniques: trocar-cannula-based sutureless fixation and sutured scleral fixation. Clinical outcomes were compared before and 1-, 3-, 6-, and 12-month follow-ups after the operation.Results:A total of 51 patients were followed over a 12-month period after the operation, including 28 eyes in the sutureless group and 23 eyes in the sutured group. Best-corrected visual acuity and spherical equivalent values reached targeted values faster in the sutureless scleral fixation of the intraocular lens. However, no significant difference was observed between the two groups. For intraocular lens capture, there was a statistically significant difference observed in the incidence of postoperative complications, which was demonstrated by one eye in the sutureless group and seven in the sutured group (P = 0.009). To exclude the effect of corneal astigmatism, surgically induced astigmatism was calculated based on the astigmatism value 1 year after surgery. It was found that the sutureless technique significantly reduced the occurrence of astigmatism (2.43 +/- 1.42 vs. 1.65 +/- 0.94, P = 0.031).Conclusion:In a 1-year follow-up period, the trocar-cannula-based sutureless technique was reliable and effective. Sutureless fixation was associated with fewer postoperative complications and lower surgically induced astigmatism values than those with sutured fixation.
引用
收藏
页码:815 / 822
页数:8
相关论文
共 50 条
  • [41] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [42] Exposure of haptic of posterior chamber intraocular lens after sutureless intrascleral fixation
    Yoshitsugu Matsui
    Hisashi Matsubara
    Tsukasa Hanemoto
    Mineo Kondo
    BMC Ophthalmology, 15
  • [43] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-Assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 39 - 43
  • [44] Sutureless glueless intrascleral fixation of posterior chamber intraocular lens: Boon for aphakic
    Shekhawat, Nagendra
    Goyal, Karishma
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1454 - 1458
  • [45] Sutureless intrascleral fixation of a custom-tailored iris prosthesis with an intraocular lens
    Gooi, Patrick
    Teichman, Joshua C.
    Ahmed, Iqbal Ike K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11): : 1759 - 1763
  • [46] Comparison of Clinical Outcomes Among Sutured, Sutureless Scleral Fixation, and Retropupillary Fixation of Intraocular Lens
    Kang, Ji Eon
    Yoon, Hye Yeon
    Chung, So Hyang
    Kim, Hyun Seung
    Byun, Yong-Soo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (03): : 203 - 211
  • [47] Simplified and safe method of sutureless intrascleral posterior chamber intraocular lens fixation: Y-fixation technique
    Ohta, Toshihiko
    Toshida, Hiroshi
    Murakami, Akira
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (01): : 2 - 7
  • [48] Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy
    Marianelli, Bruna Ferraco
    Mendes, Thais Sousa
    de Almeida Manzano, Roberta Pereira
    Garcia, Patricia Novita
    Teixeira, Ivan Corso
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2019, 5 (01)
  • [49] Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy
    Bruna Ferraço Marianelli
    Thaís Sousa Mendes
    Roberta Pereira de Almeida Manzano
    Patrícia Novita Garcia
    Ivan Corso Teixeira
    International Journal of Retina and Vitreous, 5
  • [50] Enhanced surgical technique for sutureless intrascleral fixation of intraocular lenses
    Gabai, Andrea
    Zeppieri, Marco
    Toneatto, Giacomo
    Salati, Carlo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12): : E75 - E79