Ratiometric Fluorescence and Afterglow Lifetime Dual-Channel Nanoprobe for Simultaneous Imaging of HOCl and Temperature in Arthritis

被引:5
|
作者
Zhou, Xiaotong [1 ,2 ]
Su, Xianlong [1 ,2 ]
Hu, Donghao [1 ,2 ]
Li, Ying [1 ,2 ]
Guo, Linna [1 ,2 ]
Yuan, Wei [1 ,2 ,3 ]
Yuan, Hang [1 ,2 ]
Chen, Lijun [4 ]
Xu, Ming
Luo, Shihua [5 ]
Wang, Qingbing [6 ]
Feng, Wei [1 ,2 ]
Li, Fuyou [1 ,2 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Fudan Univ, State Key Lab Mol Engn Polymers, Shanghai 200433, Peoples R China
[3] Fudan Univ, Inst Optoelect, Shanghai 200433, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Chem & Chem Engn, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Traumatol, Shanghai 200025, Peoples R China
[6] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Intervent Radiol, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
dual-channel nanoprobe; detection of hypochlorous acidand temperature; ratiometric fluorescence imaging; afterglow lifetime imaging; arthritis model; RHEUMATOID-ARTHRITIS; IN-VIVO; PROBE; INFLAMMATION; PROGRESSION; STRESS; BRIGHT;
D O I
10.1021/acsami.3c12666
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Arthritis is a joint disorder that potentially causes permanent joint damage and eventual disability without effective treatment. Clinical detection methods, including in vitro blood tests and anatomical imaging, still have limitations in achieving real-time in situ early detection of arthritis. In this work, a dual-channel luminescence nanoprobe (AGNPs-Cy7) is reported, which combines a cyanine dye and a photochemical reaction-based afterglow system for real-time in vivo imaging of arthritis. AGNPs-Cy7 simultaneously detect hypochlorous acid (HOCl) and temperature, two important indicators associated with the early development of arthritis, by monitoring the respective changes in independent ratiometric fluorescence and afterglow lifetime signals. The anti-interference properties of both the ratiometric fluorescence signal and afterglow lifetime signal enhance sensing accuracy compared to the single luminescence intensity. The developed probe successfully reveals the simultaneous increase in HOCl concentration and temperature in an arthritis mouse model.
引用
收藏
页码:50916 / 50925
页数:10
相关论文
共 50 条
  • [41] A highly selective ratiometric visual and red-emitting fluorescent dual-channel probe for imaging fluoride anions in living cells
    Zhu, Baocun
    Kan, He
    Liu, Jingkai
    Liu, Hanging
    Wei, Qin
    Du, Bin
    BIOSENSORS & BIOELECTRONICS, 2014, 52 : 298 - 303
  • [42] Estimating weak ratiometric signals in imaging data. II. Meta-analysis with multiple, dual-channel datasets
    Sornborger, Andrew
    Broder, Josef
    Majumder, Anirban
    Srinivasamoorthy, Ganesh
    Porter, Erika
    Reagin, Sean S.
    Keith, Charles
    Lauderdale, James D.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (09) : 2185 - 2194
  • [43] Simultaneous dual-color fluorescence lifetime imaging with novel red-shifted fluorescent proteins
    Laviv, Tal
    Kim, Benjamin B.
    Chu, Jun
    Lam, Amy J.
    Lin, Michael Z.
    Yasuda, Ryohei
    NATURE METHODS, 2016, 13 (12) : 989 - +
  • [44] Simultaneous dual-color fluorescence lifetime imaging with novel red-shifted fluorescent proteins
    Tal Laviv
    Benjamin B Kim
    Jun Chu
    Amy J Lam
    Michael Z Lin
    Ryohei Yasuda
    Nature Methods, 2016, 13 : 989 - 992
  • [45] Simultaneous visualization of density and pressure in hydrogen leakage based on self-imaging via dual-channel interference
    Miao, Yang
    Jia, Chenghao
    Hua, Yang
    Li, Yuejuan
    Tang, Qingchun
    Xu, Jingxiang
    Wu, Di
    Zhang, Xiaolu
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 177 : 976 - 985
  • [46] Interleaving optical coherence microscopy with dual-channel fluorescence microscopy for simultaneous co-registration of structural and functional information
    Maddipatla, Reddikumar
    Tankam, Patrice
    MULTIMODAL BIOMEDICAL IMAGING XVI, 2021, 11634
  • [47] Simultaneous Assessment of Luminal Integrity and Vascular Perfusion of the Gastrointestinal Tract Using Dual-Channel Near-Infrared Fluorescence
    Ashitate, Yoshitomo
    Vooght, Carrie S.
    Hutteman, Merlijn
    Oketokoun, Rafiou
    Choi, Hak Soo
    Frangioni, John V.
    MOLECULAR IMAGING, 2012, 11 (04) : 301 - 308
  • [48] A dual-channel fluorogenic probe for simultaneous and distinguishable imaging of protein monothiols and vicinal-dithiols in live cells
    Gao, Wei
    Lu, Shuaimin
    Zhang, Shilong
    Liu, Junjie
    Kang, Jin
    Yin, Caixia
    DYES AND PIGMENTS, 2023, 212
  • [49] Simultaneous dual-channel imaging to quantify interdependent protein recruitment to laser-induced DNA damage sites
    Garbrecht, Joachim
    Hornegger, Harald
    Herbert, Sebastien
    Kaufmann, Tanja
    Gotzmann, Josef
    Elsayad, Kareem
    Slade, Dea
    NUCLEUS, 2018, 9 (01) : 474 - 491
  • [50] Intrinsic dual emissive insulin capped Au/Ag nanoclusters as single ratiometric nanoprobe for reversible detection of pH and temperature and cell imaging
    Shamsipur, Mojtaba
    Babaee, Elaheh
    Gholivand, Mohammad-Bagher
    Molaabasi, Fatemeh
    Hajipour-Verdom, Behnam
    Sedghi, Mosslim
    BIOSENSORS & BIOELECTRONICS, 2024, 250