Performance analysis of a metal hydride refrigeration system

被引:2
|
作者
Ge, Y. T. [1 ]
Lang, P. Y.
机构
[1] Ctr Civil & Bldg Serv Engn CCiBSE, London, England
基金
英国工程与自然科学研究理事会;
关键词
Metal hydride refrigeration systems; Transient model development; Pressure; Concentration and temperature (PCT) profiles; Model validation and simulation; Performance analysis and optimisation; HEAT-PUMP; OPERATING CHARACTERISTICS; SORPTION SYSTEMS; ENERGY-SYSTEMS; ANALYSIS MODEL;
D O I
10.1016/j.applthermaleng.2023.121264
中图分类号
O414.1 [热力学];
学科分类号
摘要
The varying applications of metal hydride refrigeration systems, such as cold storage and space air conditioning, grant them important advantages over conventional ones. These advantages include being a low-grade heat driven, more environmentally friendly and renewable working fluid with greater compactness and fewer moving parts. However, a metal hydride refrigeration system always operates under unsteady conditions due to the cyclic hydriding and dehydriding processes involved. To analyse and optimise the metal hydride refrigeration system's design and performance, in this paper, a comprehensive transient system model has been developed with a new and revised intrinsic kinetic correlation inclusive of the essential operating controls and applicable process conditions of regeneration, cooling and transitions in between. In addition, the correlative model on the characterisation process of pressure, concentration and temperature (PCT) profiles for the metal hydride alloys employed in the system has been developed and is introduced briefly in this paper. It is integrated in the system model and ensures the accurate prediction of maximum capacities for the metal hydride isothermal desorption and absorption processes. The developed transient system model has been validated through comparison with experimental results from literature on the medium-temperature cooling process of a metal hydride refrigeration system. The model simulation is conducted for a specially designed low-temperature metal hydride refrigeration system at different operating conditions and controls. In quantity, when the high-grade heat source temperature increases from 90 degrees C to 120 degrees C, the low-grade heat source temperature increases from 20 degrees C to 10 degrees C, the medium-grade heat sink temperature decreases from 30 degrees C to 15 degrees C, and the time period for regeneration or cooling process decreases from 10 min to 4 min, the cooling COP increases by 112.0%, 136.6%, 19.3% and 31.8% respectively. The optimisation strategies for the system operating conditions and controls are therefore recommended based on the detailed performance analyses of the system simulation results.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] METAL HYDRIDE ENERGY-SYSTEMS PERFORMANCE EVALUATION .B. PERFORMANCE ANALYSIS MODEL OF DUAL METAL HYDRIDE ENERGY-SYSTEMS
    GAMBINI, M
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1994, 19 (01) : 81 - 97
  • [32] PERFORMANCE ANALYSIS OF MULTIPURPOSE REFRIGERATION SYSTEM (MRS) ON FISHING VESSEL
    Ust, Y.
    Karakurt, A. Sinan
    Gunes, U.
    POLISH MARITIME RESEARCH, 2016, 23 (02) : 48 - 56
  • [33] Investigation Analysis on the performance improvement of a vapor compression refrigeration system
    Chandra, M. Ravi
    Reddy, K. Manikanth
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 1638 - +
  • [34] The performance analysis of a LCPV/T assisted absorption refrigeration system
    Zhang Heng
    Chen Feipeng
    Liu Yang
    Chen Haiping
    Liang Kai
    Yang Boran
    RENEWABLE ENERGY, 2019, 143 : 1852 - 1864
  • [35] The performance of steam ejector refrigeration system based on alternative analysis
    Kitrattana, Borirak
    Aphornratana, Satha
    Thongtip, Tongchana
    2017 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2017, 138 : 482 - 487
  • [37] THERMODYNAMIC ANALYSIS OF PERFORMANCE OF LIQUID INJECTOR FOR EJECTION REFRIGERATION SYSTEM
    Pawluczuk, Andrzej
    Butrymowicz, Dariusz
    Smierciew, Kamil
    Gagan, Jerzy
    9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND COOLANTS, 2017, : 42 - 49
  • [38] Influential factors and optimization analysis of adsorption refrigeration system performance
    Zhang, Xueling
    Wang, Feifei
    Lei, Xudong
    Wang, Yanling
    Zhang, Qi
    Wu, Xuehong
    Jin, Tingxiang
    Wang, Yujing
    AIP ADVANCES, 2020, 10 (10)
  • [40] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi 'an
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39