Deep-Learning-Based Image Denoising in Imaging of Urolithiasis: Assessment of Image Quality and Comparison to State-of-the-Art Iterative Reconstructions

被引:2
|
作者
Terzis, Robert [1 ]
Reimer, Robert Peter [1 ]
Nelles, Christian [1 ]
Celik, Erkan [1 ]
Caldeira, Liliana [1 ]
Heidenreich, Axel [2 ]
Storz, Enno [2 ]
Maintz, David [1 ]
Zopfs, David [1 ]
Hokamp, Nils Grosse [1 ]
机构
[1] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, D-50937 Cologne, Germany
[2] Univ Hosp Cologne, Dept Urol, Uro Oncol, Robot Assisted & Specialized Urol Surger, D-50937 Cologne, Germany
关键词
deep learning; diagnostic imaging; image enhancement; kidney calculi; tomography; X-ray computed; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; CT;
D O I
10.3390/diagnostics13172821
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to compare the image quality and diagnostic accuracy of deep-learning-based image denoising reconstructions (DLIDs) to established iterative reconstructed algorithms in low-dose computed tomography (LDCT) of patients with suspected urolithiasis. LDCTs (CTDI-vol, 2 mGy) of 76 patients (age: 40.3 +/- 5.2 years, M/W: 51/25) with suspected urolithiasis were retrospectively included. Filtered-back projection (FBP), hybrid iterative and model-based iterative reconstruction (HIR/MBIR, respectively) were reconstructed. FBP images were processed using a Food and Drug Administration (FDA)-approved DLID. ROIs were placed in renal parenchyma, fat, muscle and urinary bladder. Signal- and contrast-to-noise ratios (SNR/CNR, respectively) were calculated. Two radiologists evaluated image quality on five-point Likert scales and urinary stones. The results showed a progressive decrease in image noise from FBP, HIR and DLID to MBIR with significant differences between each method (p < 0.05). SNR and CNR were comparable between MBIR and DLID, while it was significantly lower in HIR followed by FBP (e.g., SNR: 1.5 +/- 0.3; 1.4 +/- 0.4; 1.0 +/- 0.3; 0.7 +/- 0.2, p < 0.05). Subjective analysis confirmed best image quality in MBIR, followed by DLID and HIR, both being superior to FBP (p < 0.05). Diagnostic accuracy for urinary stone detection was best using MBIR (0.94), lowest using FBP (0.84) and comparable between DLID (0.90) and HIR (0.90). Stone size measurements were consistent between all reconstructions and showed excellent correlation (r(2) = 0.958-0.975). In conclusion, MBIR yielded the highest image quality and diagnostic accuracy, with DLID producing better results than HIR and FBP in image quality and matching HIR in diagnostic precision.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Image quality assessment of different iterative reconstructions on PET images:: A phantom study
    Zabalza, L.
    Marti-Climent, J. M.
    Prieto, E.
    Gomez, M.
    Lecumberrri, P.
    Bustince, H.
    Arbizu, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S314 - S314
  • [32] Image-Based 3D Object Reconstruction: State-of-the-Art and Trends in the Deep Learning Era
    Han, Xian-Feng
    Laga, Hamid
    Bennamoun, Mohammed
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2021, 43 (05) : 1578 - 1604
  • [33] Deep-Learning-Based Block Similarity Evaluation for Image Forensics
    Wang, Hsin-Tzu
    Su, Po-Chyi
    2020 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN (ICCE-TAIWAN), 2020,
  • [34] A Comprehensive Review of Deep-Learning-Based Methods for Image Forensics
    Camacho, Ivan Castillo
    Wang, Kai
    JOURNAL OF IMAGING, 2021, 7 (04)
  • [35] Deep-learning-based image segmentation for image-based computational hemodynamic analysis of abdominal aortic aneurysms: a comparison study
    Lyu, Zonghan
    King, Kristin
    Rezaeitaleshmahalleh, Mostafa
    Pienta, Drew
    Mu, Nan
    Zhao, Chen
    Zhou, Weihua
    Jiang, Jingfeng
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [36] Deep-Learning-Based Image Reconstruction and Enhancement in Optical Microscopy
    de Haan, Kevin
    Rivenson, Yair
    Wu, Yichen
    Ozcan, Aydogan
    PROCEEDINGS OF THE IEEE, 2020, 108 (01) : 30 - 50
  • [37] Deep-Learning-Based Bughole Detection for Concrete Surface Image
    Yao, Gang
    Wei, Fujia
    Yang, Yang
    Sun, Yujia
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [38] Deep-learning-based image reconstruction for compressed ultrafast photography
    Ma, Yayao
    Feng, Xiaohua
    Gao, Liang
    OPTICS LETTERS, 2020, 45 (16) : 4400 - 4403
  • [39] A Review of Deep-Learning-Based Medical Image Segmentation Methods
    Liu, Xiangbin
    Song, Liping
    Liu, Shuai
    Zhang, Yudong
    SUSTAINABILITY, 2021, 13 (03) : 1 - 29
  • [40] Iterative reconstructions in multiphasic CT imaging of the liver: qualitative and task-based analyses of image quality
    Pasquier, H.
    Gardavaud, F.
    Chiaradia, M.
    Zanca, F.
    Herin, E.
    Mule, S.
    Rahmouni, A.
    Luciani, A.
    CLINICAL RADIOLOGY, 2018, 73 (09) : 834.e9 - 834.e16