Development of tissue paper-based chemosensor and demonstration for the selective detection of Cu2+ and Hg2+ ions

被引:5
|
作者
Thangaraj, Bharathkumar [1 ]
Ponram, Marimuthu [1 ]
Ranganathan, Suresh [2 ,3 ]
Sambath, Baskaran [4 ]
Cingaram, Ravichandran [1 ]
Iyer, Sathiyanarayanan Kulathu [5 ]
Sundaramurthy, Karthikeyan Natesan [1 ]
机构
[1] Easwari Engn Coll, Dept Chem, Chennai 600089, Tamil Nadu, India
[2] Karpagam Acad Higher Educ, Ctr Mat Chem, Coimbatore, India
[3] Karpagam Acad Higher Educ, Dept Chem, Coimbatore, India
[4] Korea Adv Inst Sci & Technol KAIST, Dept Mat Sci & Engn, Daejeon 34141, South Korea
[5] Vellore Inst Technol VIT, Sch Adv Sci, Vellore 632014, India
关键词
RARE-EARTH-ELEMENTS; THORIUM; SEPARATION; URANIUM; EXTRACTION; SAMPLES; SENSOR;
D O I
10.1039/d3ra03764a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Heavy metals emanate from natural and man-made sources, such as agricultural chemicals including fertilisers and pesticides, medical waste, and chemicals released from industries. Detection and monitoring toxic metal ions is one of the challenges confronting scientists in biological, environmental, and chemical systems. This study describes the design and synthesis of a new imidazole-based fluorescent and colourimetric chemosensor (DPICDT) for highly selective sensing of Hg2+ and Cu2+ ions in aqueous acetonitrile medium. The probe was synthesised by coupling benzil and substituted aldehyde using ethanolic ammonium acetate. The structure of DPICDT was confirmed via IR spectra, NMR, and HR-MS spectra. The DPICDT probe displayed a rapid naked-eye response towards Cu2+ ions from colourless to red-purple and significant fluorescence quenching response towards Hg2+ over other competitive metal ions in both solution and solid support. The binding modes of DPICDT with Cu2+ and Hg2+ ions were found to be at a 1 : 1 ratio as determined using Job plot, ESI HR-MS, and the sensing mechanism was evolved by H-1 NMR titrations, HR-MS spectra, and DFT calculations. The lower detection limit was 15.1 nM for Cu2+, eventually far less than the World Health Organization guideline for drinking water (Cu2+ - 31.5 mu M) and 1.17 mu M for Hg2+ (permissible concentration 2 ppb). Promisingly, the tissue paper-based DPICDT test strips and silica-supported DPICDT were developed and demonstrated for on-site application without resorting to expensive instruments.
引用
收藏
页码:26023 / 26030
页数:8
相关论文
共 50 条
  • [31] Highly Selective and Sensitive Colorimetric and Fluorescent Chemosensor for Rapid Detection of Ag+, Cu2+ and Hg2+ Based on a Simple Schiff Base
    Zhang, Shanshan
    Wu, Xingxing
    Niu, Qingfen
    Guo, Zongrang
    Li, Tianduo
    Liu, Haixia
    JOURNAL OF FLUORESCENCE, 2017, 27 (02) : 729 - 737
  • [32] Thiophenol amine-based Schiff base for colorimetric detection of Cu2+ and Hg2+ ions
    Sidana, Nancy
    Devi, Pooja
    Kaur, Harminder
    OPTICAL MATERIALS, 2022, 124
  • [33] A highly selective, sensitive and reusable BODIPY based 'OFF/ON' fluorescence chemosensor for the detection of Hg2+ Ions
    Maity, Apurba
    Sil, Amit
    Nad, Subhra
    Patra, Sanjib K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 299 - 308
  • [34] A simple urea-based multianalyte and multichannel chemosensor for the selective detection of F-, Hg2+ and Cu2+ in solution and cells and the extraction of Hg2+ and Cu2+ from real water sources: a logic gate mimic ensemble
    Mondal, Amita
    Chowdhury, Additi Roy
    Bhuyan, Samuzal
    Mukhopadhyay, Subhra Kanti
    Banerjee, Priyabrata
    DALTON TRANSACTIONS, 2019, 48 (13) : 4375 - 4386
  • [35] Cinnamaldehyde-Based Chemosensor for Colorimetric Detection of Cu2+ and Hg2+ in a Near-Perfect Aqueous Solution
    Cho, Hanna
    Chae, Ju Byeong
    Kim, Cheal
    CHEMISTRYSELECT, 2019, 4 (09): : 2795 - 2801
  • [36] Epoxy-based oligomer containing dithia-aza-based naphthylazobenzene pendant: a chemosensor for Hg2+ and Cu2+ ions
    Ghosh, Samaresh
    Manna, Rajkumar
    SUPRAMOLECULAR CHEMISTRY, 2011, 23 (08) : 558 - 562
  • [37] A Colorimetric and Fluorescent Chemosensor for the Selective Detection of Cu2+ and Zn2+ Ions
    Min Seon Kim
    Tae Geun Jo
    Hye Mi Ahn
    Cheal Kim
    Journal of Fluorescence, 2017, 27 : 357 - 367
  • [38] A Colorimetric and Fluorescent Chemosensor for the Selective Detection of Cu2+ and Zn2+ Ions
    Kim, Min Seon
    Jo, Tae Geun
    Ahn, Hye Mi
    Kim, Cheal
    JOURNAL OF FLUORESCENCE, 2017, 27 (01) : 357 - 367
  • [39] Development of a paper-based sensor for the qualitative and quantitative detection of Cu2+ in water
    Xu, Yinchao
    Enomae, Toshiharu
    NORDIC PULP & PAPER RESEARCH JOURNAL, 2017, 32 (02) : 237 - 243
  • [40] Hg2+ and Cu2+ selective detection using a dual channel receptor based on thiopyrylium scaffoldings
    Abalos, Tatiana
    Jimenez, Diego
    Martinez-Manez, Ramon
    Ros-Lis, Jose Vicente
    Royo, Santiago
    Sancenon, Felix
    Soto, Juan
    Costero, Ana M.
    Gil, Salvador
    Parra, Margarita
    TETRAHEDRON LETTERS, 2009, 50 (27) : 3885 - 3888