On the energy impact of cool roofs in Australia

被引:19
|
作者
Garshasbi, Samira [1 ]
Feng, Jie [1 ]
Paolini, Riccardo [1 ]
Duverge, Jean Jonathan [1 ]
Bartesaghi-Koc, Carlos [2 ]
Arasteh, Samaneh [1 ]
Khan, Ansar [3 ]
Santamouris, Mat [1 ]
机构
[1] Univ New South Wales, Sch Built Environm, Kensington, Australia
[2] Univ Adelaide, Fac Sci Engn & Technol, Sch Architecture & Built Environm, Adelaide, Australia
[3] Univ Calcutta, Lalbaba Coll, Dept Geog, Kolkata, India
关键词
Combined building -scale and urban -scale; implementation of cool roofs; Cooling and heating energy impacts; Indoor temperature; Peak electricity demand; Energy efficiency; Thermal insulation; URBAN HEAT-ISLAND; THERMAL COMFORT; CLIMATE-CHANGE; MITIGATION; TEMPERATURE; PERFORMANCE; BUILDINGS; COATINGS; TECHNOLOGIES; MORTALITY;
D O I
10.1016/j.enbuild.2022.112577
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Urban overheating is a serious environmental issue with a significant impact on cooling loads, peak elec-tricity demand, indoor air temperature, health, pollution, sustainability, and the economy. Cool roofs - which are characterised by high solar reflectance (q) or albedo and high thermal emissivity (e) - are one of the most effective technologies to mitigate the urban overheating effect and its undesirable impacts. The existing literature on the energy impacts of cool roofs in various building types and climate zones is vast but fragmented and predominantly assessed the building-scale and urban-scale benefits separately. Here, we computed the energy conservation potential of cool roofs in 17 building archetypes with different occupation hours, internal heat gains, thermal insulation levels, and building heights under various Australian climates. This study presents a holistic approach to assessing the magnitude and spa-tial variation of the cooling load savings, the peak electricity demand reductions, and indoor air temper-ature reductions generated by the building-scale and combined building-scale and urban-scale implementation of cool roofs in all representative building types under various climate conditions in Australia. In Sydney, a city with a warm/mild temperate climate, cool roofs can reduce the cooling loads of a typical low-rise office building without roof insulation by 10.2-13.8 kWh/m(2) (37.6-42.0 %) during the summer months of January and February. When cool roofs are implemented in both individual build-ings and the whole urban area, the cooling load conservation potential for the same building increases to 14.9-17.4 kWh/m(2) (50.3-63.7 %). The corresponding peak electricity demand and indoor air temperature reductions by the combined building-scale and urban-scale application of cool roofs are 53-70 % and 11.2-12.0 degrees C, respectively. The energy conservation potential of cool roofs can be noticeable even for high-rise buildings with a high level of thermal insulation. We estimated that the cooling conservation potential by combined building-scale and urban-scale application of cool roofs can range between 4.0 and 7.1 kWh/m(2) (29.3-48.3 %) in a new high-rise residential building with high levels of thermal insula-tion to 18.5-24.5 kWh/m(2) (23-29.6 %) in an existing low-rise shopping mall centre with low levels of thermal insulation in Sydney. Cool roofs lead to additional savings as the reduced temperature increases the energy efficiency of air conditioning systems, with cooling load savings between 0.6 and 3.7 kWh/m(2) (3-11 %) for a typical low-rise office building without roof insulation in Sydney. Also, the heating load penalties induced by cool roofs are negligible compared to the cooling load savings in all building types and Australian cities/climate zones except for non-commercial buildings in the cold climate of Hobart. Policymakers can use the results of this study to obtain a deep knowledge of the expected performance of cool roofs when applied city-wide to mitigate urban overheating and counterbalance its adverse impacts on energy uses and indoor thermal comfort. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Comparison of software models for energy savings from cool roofs
    New, Joshua
    Miller, William A.
    Huang, Yu
    Levinson, Ronnen
    ENERGY AND BUILDINGS, 2016, 114 : 130 - 135
  • [22] Cool roofs boost the energy production of photovoltaics: Investigating the impact of roof albedo on the energy performance of monofacial and bifacial photovoltaic modules
    Vasilakopoulou, K.
    Ulpiani, G.
    Khan, A.
    Synnefa, A.
    Santamouris, M.
    SOLAR ENERGY, 2023, 265
  • [23] Special section: Cool Roofs, Cool Pavements, Cool Cities, and Cool World
    Akbari, H.
    Santamouris, M.
    ENERGY AND BUILDINGS, 2012, 55 : 1 - 1
  • [24] Preliminary studies of a cool roofs' energy-rating system in Italy
    Zinzi, Michele
    Carnielo, Emiliano
    Federici, Alessandro
    ADVANCES IN BUILDING ENERGY RESEARCH, 2014, 8 (01) : 84 - 96
  • [25] Effect of cool roofs on commercial buildings energy use in cold climates
    Hosseini, Mirata
    Akbari, Hashem
    ENERGY AND BUILDINGS, 2016, 114 : 143 - 155
  • [26] Energy Performance of Cool Roofs Followed by Development of Practical Design Tool
    Saber, Named H.
    Maref, Wahid
    FRONTIERS IN ENERGY RESEARCH, 2019, 7
  • [27] Cool roofs impact on building thermal response: A French case study
    Bozonnet, E.
    Doya, M.
    Allard, F.
    ENERGY AND BUILDINGS, 2011, 43 (11) : 3006 - 3012
  • [28] Hot solutions for cool roofs
    Arkema Inc.
    不详
    Finishing Today, 2007, 83 (02): : 34 - 39
  • [29] Tiny thing for cool roofs
    Greenwood, Peter
    Nordin, Jan
    Spacek, Vladimir
    Farbe und Lack, 2024, 130 (02): : 38 - 43
  • [30] Cool materials and cool roofs: Potentialities in Mediterranean buildings
    Zinzi, Michele