Portable Multi-Channel Electrochemical Device with Good Interaction and Wireless Connection for On-Site Testing

被引:4
|
作者
Xu, Yifei [1 ]
Ning, Haohao [1 ]
Yu, Shixin [1 ]
Liu, Shikun [1 ]
Zhang, Yan [1 ]
Niu, Chunyan [2 ]
Zhang, Yongzhuo [3 ]
Low, Sze Shin [4 ]
Liu, Jingjing [1 ]
机构
[1] Northeast Elect Power Univ, Sch Automat Engn, Jilin 132012, Peoples R China
[2] Natl Inst Metrol, Ctr Adv Measurement Sci, Beijing 100029, Peoples R China
[3] Natl Inst Metrol, Beijing 100029, Peoples R China
[4] Univ Nottingham Ningbo, Nottingham Ningbo China Beacons Excellence Res & I, Ningbo 315100, Peoples R China
基金
中国国家自然科学基金;
关键词
on-site testing; portable; Narrowband Internet of Things; cloud processing; MANAGEMENT; SECURITY;
D O I
10.3390/mi14010142
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is very important to rapidly test the key indicators of water in the field to fully evaluate the quality of the regional water environment. However, a high-resolution measuring device that can generate small currents for low-concentration analytes in water samples is often bulky, complex to operate, and difficult for data sharing. This work introduces a portable multi-channel electrochemical device with a small volume, good interaction, and data-sharing capabilities called PMCED. The PMCED provides an easy-to-operate graphical interactive interface to conveniently set the parameters for cyclic voltammetry or a differential pulse method performed by the four electrode channels. At the same time, the device, with a current sensitivity of 100 nA V-1, was applied to the detection of water samples with high background current and achieved a high-resolution measurement at low current levels. The PMCED uses the Narrow Band Internet of Things (NB-IoT) to meet the needs for uploading data to the cloud in remote areas. The electrochemical signal preprocessing and chemometrics models run in the cloud, and the final results are visualized on a web page, providing a remote access channel for on-site testing results.
引用
收藏
页数:12
相关论文
共 44 条
  • [41] Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer
    Gao, Jie
    Huang, Wenzheng
    Chen, Zhipeng
    Yi, Changqing
    Jiang, Lelun
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 287 : 102 - 110
  • [42] A Multi-Channel Handheld Diagnostic Device Based on Green Biomimetic Material for Point-of-Care Testing of Vitamin C in Human Fluids
    Fu, Donglei
    Dong, Yueyan
    Yin, Junping
    Zhang, Bowen
    Zhang, Shuaibo
    Deng, Junjie
    Shui, Hua
    Liu, Xinghai
    ADVANCED HEALTHCARE MATERIALS, 2024,
  • [43] Architecture of a multi-channel and easy-to-make microfluidic paper-based colorimetric device (μPCD) towards selective and sensitive recognition of uric acid by AuNPs: an innovative portable tool for the rapid and low-cost identification of clinically relevant biomolecules
    Farshchi, Fatemeh
    Saadati, Arezoo
    Hasanzadeh, Mohammad
    Seidi, Farzad
    RSC ADVANCES, 2021, 11 (44) : 27298 - 27308
  • [44] One-drop chemosensing of dapoxetine hydrochloride using opto-analysis by multi-channel μPAD decorated silver nanoparticles: introducing a paper-based microfluidic portable device/sensor toward naked-eye pharmaceutical analysis by lab-on-paper technology
    Bahavarnia, Farnaz
    Kohansal, Fereshteh
    Hasanzadeh, Mohammad
    RSC ADVANCES, 2024, 14 (04) : 2610 - 2620