Heat and moisture transfer in wall-to-floor thermal bridges and its influence on thermal performance

被引:10
|
作者
Xue, Yucong [1 ,2 ,3 ]
Fan, Yifan [1 ,2 ,3 ]
Chen, Shuqin [1 ]
Wang, Zitao [4 ]
Gao, Weijun [5 ]
Sun, Zhijian [6 ]
Ge, Jian [1 ,2 ,3 ]
机构
[1] Zhejiang Univ, Coll Civil Engn & Architecture, Hangzhou, Peoples R China
[2] Zhejiang Univ, Ctr Balance Architecture, Hangzhou, Peoples R China
[3] Zhejiang Univ, Int Res Ctr Green Bldg & Low Carbon City, Int Campus, Hangzhou, Peoples R China
[4] Shanghai Zitu Educ Technol Co Ltd, Shanghai, Peoples R China
[5] Univ Kitakyushu, Fac Environm Engn, Kitakyushu, Japan
[6] Zhejiang Univ, Coll Energy Engn, Hangzhou, Peoples R China
关键词
Coupled heat and moisture transfer (HAMT); Wall-to-floor thermal bridge (WFTB); Building energy consumption; POROUS BUILDING-MATERIALS; HYGROTHERMAL CONDITIONS; ENERGY PERFORMANCE; HYGRIC PROPERTIES; CONDUCTIVITY; MODEL; RETROFIT; SYSTEMS; IMPACT; FLOWS;
D O I
10.1016/j.enbuild.2022.112642
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A significant portion of the cooling or heating load of buildings is contributed by relatively large heat flux through thermal bridges. Water vapour concentration significantly alters thermal conductivity and heat transfer characteristics within the thermal bridges, affecting building energy consumption, particularly in humid climates. Moreover, the condensation on the building envelope is highly related to the tempera-ture and moisture distribution, which threatens the safety of the building structure. The heat and mois-ture transfer presents strong coupling effects. Nevertheless, the coupled heat and moisture transfer (HAMT) within thermal bridges and its influence on the building energy consumption were less studied. In this study, field experiments and validated numerical models were conducted to investigate the heat and moisture transfer in the wall-to-floor thermal bridge (WFTB) in a humid and hot summer cold winter region of China (Hangzhou city). The results show that the heat transfer is underestimated if the moisture is not considered. The differences in heat transfer between the WFTB and the main part of the wall were reduced when considering the coupling effect of heat and moisture transfer, as the thermal performance of the wall is more sensitive to moisture than that of the WFTB region. Furthermore, if the significant moisture transfer is considered, the overall thermal conductivity of the WFTB has a risk of counterintu-itively increasing when a thermal insulation layer is added. The reason for this is that the thermal insu-lation layer may raise the moisture content in the WFTB region, subsequently increasing the thermal conductivity.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Study of heat and moisture transfer and reaction in food thermal processing
    Sakai N.
    Japan Journal of Food Engineering, 2018, 19 (02): : 57 - 78
  • [22] MASONRY THERMAL CONDUCTIVITY INFLUENCE ON THE THERMAL PERFORMANCE OF A THERMALLY INSULATED WALL
    Moga, Ligia
    Moga, Ioan
    JOURNAL OF APPLIED ENGINEERING SCIENCES, 2011, 1 (03): : 51 - 58
  • [23] Thermal bridges of living wall systems
    Tudiwer, David
    Teichmann, Florian
    Korjenic, Azra
    ENERGY AND BUILDINGS, 2019, 205
  • [24] Ceramic surface finish: its influence on the heat transfer in thermal shock tests
    Tomba, AG
    Cavalieri, AL
    MATERIALS LETTERS, 2000, 42 (04) : 240 - 245
  • [25] The influence of heat and moisture transfer in soil on the performance of the ground heat exchanger
    Shen, Guomin
    Lu, Chunfang
    Wang, Yi
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 2120 - 2127
  • [26] Dynamic and heat transfer of a Pr < 1 thermal flow around a fin on the thermal wall
    Ma, Jia
    Xu, Feng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 111 : 696 - 708
  • [27] Analysis of influence of heat exchanger fouling on heat transfer performance based on thermal fluid coupling
    HUANG Si
    MURAD Tariq
    NIU Qifeng
    LIN Guangtang
    CHEN Jianxun
    排灌机械工程学报, 2023, 41 (07) : 695 - 700
  • [28] Influence of grout thermal properties on heat-transfer performance of ground source heat exchangers
    Zhou, Yasu
    Zhang, Yongcai
    Xu, Yongliang
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (05) : 461 - 469
  • [29] Development and thermal performance of a wall heat collection prototype
    Lai, Chi-ming
    Chen, Rong-Horng
    Huang, C. S.
    BUILDING AND ENVIRONMENT, 2012, 57 : 156 - 164
  • [30] PCMs heat transfer performance enhancement with expanded graphite and its thermal stability
    Jin, Yi
    Wan, Qingming
    Ding, Yulong
    NEW PARADIGM OF PARTICLE SCIENCE AND TECHNOLOGY, PROCEEDINGS OF THE 7TH WORLD CONGRESS ON PARTICLE TECHNOLOGY, 2015, 102 : 1877 - 1884