Comparison of a commercially available veterinary digital refractometer to analogue refractometer and laboratory chemistry analyzer in the evaluation of canine serum total protein

被引:0
|
作者
Carignan, Katie [1 ]
Thevelein, Britt A. L. [1 ]
Brainard, Benjamin M. [1 ]
Koenig, Amie [1 ]
机构
[1] Univ Georgia, Dept Small Anim Med & Surg, Coll Vet Med, Athens, GA 30602 USA
关键词
HYPOPROTEINEMIA; GUIDELINES;
D O I
10.2460/javma.23.01.0020
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To assess the agreement between measurements of total protein (TP) concentrations in canine serum samples between a commercially available veterinary digital refractometer (DR), an analog handheld refractometer (AR), and a laboratory-based chemistry analyzer (LAB). An additional objective was to assess the effects of various potential interferents (ie, hyperbilirubinemia, increased BUN, hyperglycemia, hemolysis, and lipemia) on DR measurements. SAMPLE 108 canine serum samples. PROCEDURES Serum samples were measured in duplicate on the DR, which reported TP concentration, assessed via optical reflectance and critical angle measurement. These serum samples were also assessed on the AR and LAB for comparison. Serum samples with grossly visible lipemia, hemolysis, and icterus were noted. Medical records were retrospectively assessed to determine concentrations of BUN, glucose, and bilirubin. RESULTS Method comparisons among the various data generated by the analyzers were completed using linear regression, Bland Altman, and calculation of intraclass coefficients. Mean bias between DRTP and LABTP in samples without potential interferents was 0.54 g/dL with 95% limits of agreement of -0.17 to 1.27 g/dL. One-third of DRTP samples without potential interferents had > 10% difference from their LABTP comparison. Interferents, particularly marked hyperglycemia, can result in inaccurate measurements on the DR.
引用
收藏
页数:7
相关论文
共 11 条
  • [1] Comparison of a digital and an optical analogue hand-held refractometer for the measurement of canine urine specific gravity
    Paris, J. K.
    Bennett, A. D.
    Dodkin, S. J.
    Gunn-Moore, D. A.
    VETERINARY RECORD, 2012, 170 (18) : 463 - U65
  • [2] Comparison of refractometer and biuret reaction as measurement methods for serum total protein concentration in Warmblood foals
    Straub, Janine
    Weber, Corinna
    Pusterla, Nicola
    Freise, Fritjof
    Venner, Monica
    PFERDEHEILKUNDE, 2023, 39 (01): : 5 - 11
  • [3] Evaluation of portable refractometer as an alternative method to biuret assay for measurement of serum total protein in horse
    Selamawit Solomon Andarge
    Yoseph Cherinet Megerssa
    Discover Animals, 1 (1):
  • [4] Diagnostic efficacy of hand-held digital refractometer for determining total serum protein in indigenous sheep of Pakistan
    Sharif, Madiha
    Lashari, Mushtaq Hussain
    Farooq, Umer
    Idris, Musadiq
    Afzal, Muhammad Abrar
    PLOS ONE, 2024, 19 (03):
  • [5] Comparison of chemistry analytes between 2 portable, commercially available analyzers and a conventional laboratory analyzer in reptiles
    McCain, Stephanie L.
    Flatland, Bente
    Schumacher, Juergen P.
    Clarke, Elsburgh O., III
    Fry, Michael M.
    VETERINARY CLINICAL PATHOLOGY, 2010, 39 (04) : 474 - 479
  • [6] Use of digital Brix refractometer to estimate total protein levels in Santa Ines ewes' colostrum and lambs' blood serum
    Santiago, Marcela Ribeiro
    Fagundes, Glaucia Brandao
    do Nascimento, Dayana Maria
    Faustino, Luciana Rocha
    Gomes da Silva, Cleidson Manoel
    Ferreira Dias, Francisca Elda
    de Souza, Anibal Pereira
    Arrivabene, Monica
    Cavalcante, Tania Vasconcelos
    SMALL RUMINANT RESEARCH, 2020, 182 : 78 - 80
  • [7] Evaluation of a commercially available human C-reactive protein (CRP) turbidometric immunoassay for determination of canine serum CRP concentration
    Kjelgaard-Hansen, M
    Jensen, AL
    Kristensen, AT
    VETERINARY CLINICAL PATHOLOGY, 2003, 32 (02) : 81 - 87
  • [8] Evaluation of a commercially available enzyme-linked immunosorbent assay (ELISA) for the determination of C-reactive protein in canine serum
    Kjelgaard-Hansen, M
    Kristensen, AT
    Jensen, AL
    JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2003, 50 (03): : 164 - 168
  • [9] Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals
    Davis, R
    Giguère, S
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 227 (10): : 1640 - 1645
  • [10] Comparison of automated determination of urine total protein in laboratory animals using pyrogallol red and benzethonium chloride with the Bayer ADVIA® 1650 Chemistry Analyzer.
    Sansone, J
    Taggart, PW
    Varacallo, LM
    Edwards, GY
    CLINICAL CHEMISTRY, 2003, 49 (06) : A155 - A155