The presence of polycyclic aromatic hydrocarbons in disposable baby diapers: A facile determination method via salting-out assisted liquid-liquid extraction coupled with gas chromatography-mass spectrometry

被引:3
|
作者
Georgiev, Pawel [1 ]
Belka, Mariusz [1 ]
Baczek, Tomasz [1 ]
Plotka-Wasylka, Justyna [2 ,3 ]
机构
[1] Med Univ Gdansk, Dept Pharmaceut Chem, J Hallera 107, PL-80416 Gdansk, Poland
[2] Gdansk Univ Technol, Fac Chem, Dept Analyt Chem, G Narutowicza 11-12, PL-80233 Gdansk, Poland
[3] Gdansk Univ Technol, BioTechMed Ctr, Res Ctr, G Narutowicza St 11-12, PL-80233 Gdansk, Poland
关键词
Environmental pollutants; Toxic compounds; Gas chromatography-mass spectrometry; Disposable baby diapers; Polycyclic aromatic hydrocarbons; SAFETY EVALUATION; EXPOSURE; IMPACT;
D O I
10.1016/j.chroma.2023.463981
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper we demonstrate the development of the extraction procedure of polycyclic aromatic hy-drocarbons from baby diapers along with their quantification by gas chromatography-mass spectrometry. Apart from covering plastic foil, disposable baby diapers contain sorbents intended to absorb urine and feces. A hygroscopic, adsorptive, and tough-to-homogenize fibrous sorbent, represents an analytical chal-lenge to analytical chemists. To address this issue we optimized and validated a novel extraction protocol including cryogenic homogenization, liquid-liquid extraction and further preconcentration by evaporation. By using deuterated internal standards in conjunction with matrix-matched calibration, high precision and accuracy were achieved. The limit of detection is estimated in the range of 0.041-0.221 ng/g (for fluorene and fluoranthene, respectively), which is far below the concentration currently assumed to be dangerous for children. The method was successfully applied to real samples available on the Polish mar-ket, and it was found that the amount of PAH compounds varies between manufacturers. Most diapers do not have all 15 polycyclic aromatic hydrocarbons in their composition, but there is no diaper that is free of these compounds. The most abundant in diapers was acenaphthalene, where the concentration ranged from 1.6 ng/g diaper up to 362.4 ng/g. The lowest concentration in diapers is chrysene, which is not detected in most diapers. The article is a response to the lack of a harmonized analytical method for the determination of polycyclic aromatic hydrocarbons in disposable sanitary products for children.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Quantitative determination of bromochloroacetamide in mice urine by gas chromatography combined with salting-out assisted dispersive liquid-liquid microextraction
    Hao, Yamei
    Zhou, Run
    Wang, Shunan
    Ding, Xingwang
    Zhu, Jingying
    Yang, Li
    Li, Yao
    Ding, Xinliang
    ANALYTICAL METHODS, 2023, 15 (27) : 3346 - 3352
  • [42] In situ aqueous derivatization and determination of non-steroidal anti-inflammatory drugs by salting-out-assisted liquid-liquid extraction and gas chromatography-mass spectrometry
    Grueiro Noche, Gloria
    Fernandez Laespada, Maria Esther
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    Muniategui Lorenzo, Soledad
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (37) : 6240 - 6247
  • [43] Salting out assisted liquid-liquid extraction for liquid chromatography tandem-mass spectrometry determination of amphetamine-like stimulants in meconium
    Nemeskalova, Alzbeta
    Bursova, Miroslava
    Sykora, David
    Kuchar, Martin
    Cabala, Radomir
    Hlozek, Tomas
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 172 : 42 - 49
  • [44] Determination of polycyclic aromatic hydrocarbons in commercial liquid smoke flavorings of different compositions by gas chromatography-mass spectrometry
    Guillén, MD
    Sopelana, P
    Partearroyo, MA
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (02) : 126 - 131
  • [45] Fast automated dual-syringe based dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry for the determination of polycyclic aromatic hydrocarbons in environmental water samples
    Guo, Liang
    Tan, Shufang
    Li, Xiao
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1438 : 1 - 9
  • [46] Determination of ethyl carbamate in spirits using salting-out assisted liquid-liquid extraction and high performance liquid chromatography with fluorimetric detection
    Valente, Ines Maria
    Ramos, Rui Miguel
    Goncalves, Luis Moreira
    Rodrigues, Jose Antonio
    ANALYTICAL METHODS, 2014, 6 (22) : 9136 - 9141
  • [47] Study of several aspects of a general method for the determination of polycyclic aromatic hydrocarbons in liquid smoke flavourings by gas chromatography-mass spectrometry
    Guillén, MD
    Sopelana, P
    Partearroyo, MA
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2000, 17 (01): : 27 - 44
  • [48] Determination of Acrinathrin in Water Samples by Micro Liquid-Liquid Extraction and Gas Chromatography-Mass Spectrometry
    Jose Luis Vilchez
    Pedro Espinosa
    F. Javier Arrebola
    Antonio González-Casado
    Analytical Sciences, 1997, 13 : 817 - 819
  • [49] Determination of Chlorinated Polycyclic Aromatic Hydrocarbons in Surface Water by Solid Phase Extraction Coupled with Gas Chromatography-Mass Spectrometry
    Zhang Jing-Hua
    Yuan Wen-Ting
    Gao Zhan-Qi
    Sun Cheng
    Yang Shao-Gui
    He Huan
    Zhang Li-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (10) : 1604 - 1609
  • [50] Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry
    Shimmo, M
    Adler, H
    Hyötyläinen, T
    Hartonen, K
    Kulmala, M
    Riekkola, ML
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (18) : 2985 - 2995