Efficacy of ultrasound vector flow imaging in tracking omnidirectional pulsatile flow

被引:2
|
作者
Haniel, Jonathas [1 ,2 ,3 ]
Yiu, Billy Y. S. [1 ,2 ]
Chee, Adrian J. Y. [1 ,2 ]
Huebner, Rudolf [3 ]
Yu, Alfred C. H. [1 ,2 ,4 ]
机构
[1] Univ Waterloo, Schlegel Res Inst Aging, Waterloo, ON, Canada
[2] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON, Canada
[3] Univ Fed Minas Gerais, Dept Mech Engn, Belo Horizonte, MG, Brazil
[4] Univ Waterloo, EIT-4125,200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
关键词
omnidirectional flow patterns; performance analysis; pulsatile flow dynamics; spiral flow phantom; ultrasound vector flow imaging; CONVOLUTIONAL NEURAL-NETWORKS; FLUID-STRUCTURE INTERACTION; PULSE-WAVE VELOCITY; COMPREHENSIVE APPROACH; CFD SIMULATIONS; DOPPLER; VALIDATION; TIME; SYSTEM; VERIFICATION;
D O I
10.1002/mp.16168
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundUltrasound vector flow imaging (VFI) shows potential as an emerging non-invasive modality for time-resolved flow mapping. However, its efficacy in tracking multidirectional pulsatile flow with temporal resolvability has not yet been systematically evaluated because of the lack of an appropriate test protocol. PurposeWe present the first systematic performance investigation of VFI in tracking pulsatile flow in a meticulously designed scenario with time-varying, omnidirectional flow fields (with flow angles from 0 degrees to 360 degrees). MethodsUltrasound VFI was performed on a three-loop spiral flow phantom (4 mm diameter; 5 mm pitch) that was configured to operate under pulsatile flow conditions (10 ml/s peak flow rate; 1 Hz pulse rate; carotid pulse shape). The spiral lumen geometry was designed to simulate recirculatory flow dynamics observed in the heart and in curvy blood vessel segments such as the carotid bulb. The imaging sequence was based on steered plane wave pulsing (-10 degrees, 0 degrees, +10 degrees steering angles; 5 MHz imaging frequency; 3.3 kHz interleaved pulse repetition frequency). VFI's pulsatile flow estimation performance and its ability to detect secondary flow were comparatively assessed against flow fields derived from computational fluid dynamics (CFD) simulations that included consideration of fluid-structure interactions (FSI). The mean percentage error (MPE) and the coefficient of determination (R-2) were computed to assess the correspondence of the velocity estimates derived from VFI and CFD-FSI simulations. In addition, VFI's efficacy in tracking pulse waves was analyzed with respect to pressure transducer measurements made at the phantom's inlet and outlet. ResultsPulsatile flow patterns rendered by VFI agreed with the flow profiles computed from CFD-FSI simulations (average MPE: -5.3%). The shape of the VFI-measured velocity magnitude profile generally matched the inlet flow profile. High correlation exists between VFI measurements and simulated flow vectors (lateral velocity: R-2 = 0.8; axial velocity R-2 = 0.89; beam-flow angle: R-2 = 0.98; p < 0.0001 for all three quantities). VFI was found to be capable of consistently tracking secondary flow. It also yielded pulse wave velocity (PWV) estimates (5.72 +/- 1.02 m/s) that, on average, are within 6.4% of those obtained from pressure transducer measurements (6.11 +/- 1.15 m/s). ConclusionVFI can consistently track omnidirectional pulsatile flow on a time-resolved basis. This systematic investigation serves well as a quality assurance test of VFI.
引用
收藏
页码:1699 / 1714
页数:16
相关论文
共 50 条
  • [21] Color and Vector Flow Imaging in Parallel Ultrasound With Sub-Nyquist Sampling
    Madiena, Craig
    Faurie, Julia
    Poree, Jonathan
    Garcia, Damien
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (05) : 795 - 802
  • [22] Ultrafast ultrasound coded vector Doppler imaging of blood flow velocity and resistivity
    Yan, Shaoyuan
    Ding, Yiming
    Ma, Guoao
    Fu, Yapeng
    Xu, Kailiang
    Ta, Dean
    ACTA PHYSICA SINICA, 2025, 74 (01)
  • [23] Spiral Flow Phantom for Ultrasound Flow Imaging Experimentation
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (12) : 1840 - 1848
  • [24] Flow imaging with pulsed Doppler ultrasound and flow phantoms
    Tortoli, P
    Thompson, RS
    Berti, P
    Guidi, F
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) : 1591 - 1596
  • [25] PULSATILE FLOW
    GROSSI, EA
    BAUMANN, FG
    ANNALS OF THORACIC SURGERY, 1985, 40 (06): : 638 - 638
  • [26] Four dimensional bolus tagging imaging of pulsatile flow
    Franck, A
    Jou, LD
    van Tyen, R
    Saloner, D
    MAGNETIC RESONANCE IMAGING, 2000, 18 (09) : 1097 - 1107
  • [27] Imaging pulsatile retinal blood flow in human eye
    Rao, Bin
    Yu, Lingfeng
    Chiang, Huihua Kenny
    Zacharias, Leandro C.
    Kurtz, Ronald M.
    Kuppermann, Baruch D.
    Chen, Zhongping
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (04)
  • [28] Holographic laser Doppler imaging of pulsatile blood flow
    Bencteux, Jeffrey
    Pagnoux, Pierre
    Kostas, Thomas
    Bayat, Sam
    Atlan, Michael
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (06)
  • [29] THE PULSATILE NATURE OF BLOOD-FLOW BY NMR IMAGING
    HERFKENS, RJ
    HEDLUND, LW
    DIETZ, J
    COLEMAN, RE
    INVESTIGATIVE RADIOLOGY, 1985, 20 (06) : S48 - S48
  • [30] Imaging pulsatile retinal blood flow in human eye
    University of California, Irvine, Department of Electrical Engineering and Computer Science, Irvine, CA 92612, United States
    不详
    不详
    不详
    J Biomed Opt, 2008, 4