Effects of basalt fiber reinforced polymer minibars on the flexural behavior of pre-cracked UHPC after chloride induced corrosion

被引:8
|
作者
Chen, Zhiyuan [1 ]
Wang, Xin [1 ]
Ding, Lining [2 ]
Niu, Fusheng [3 ,4 ]
Jiang, Kaidi [1 ]
Wang, Hua [3 ,4 ]
Wu, Zhishen [1 ]
机构
[1] Southeast Univ, Natl & Local Unified Engn Res Ctr Basalt Fiber Pro, Key Lab C & PC Struct, Minist Educ, Nanjing 211189, Peoples R China
[2] Nanjing Forestry Univ, Sch Civil Engn, Nanjing 210037, Peoples R China
[3] China Railway Tunnel Grp Co Ltd, Guangzhou 511458, Peoples R China
[4] Guangdong Prov Key Lab Intelligent Monitoring & Ma, Guangzhou 511458, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
UHPC; BFRP minibar; Steel fiber; Chloride induced corrosion and long-term; flexural behavior; HIGH PERFORMANCE CONCRETE; STEEL FIBER; MECHANICAL-PROPERTIES; SHAPE;
D O I
10.1016/j.jobe.2023.108382
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ultra-high performance concrete (UHPC) exhibits high shrinkage, which results in a severe risk of cracking in practice, leading to the risk of long-term mechanical performance degradation caused by steel fiber corrosion in harsh environment. This study aims to use basalt fiber reinforced polymer (BFRP) minibars to improve the long-term flexural behavior of UHPC. UHPC reinforced with 3 % BFRP minibars and 3 % steel fibers were pretreated for initial crack and cured in chloride solution for various dry-wet cycles, respectively. The long-term tensile behavior of BFRP minibar and steel fiber, and long-term flexural behavior of UHPC with BFRP minibars and steel fibers were systematically tested and evaluated before and after corrosion, respectively. Ac-cording to the test results, compared to steel fiber, BFRP minibar showed a much better chloride resistance, leading to a great improvement in long-term flexural behavior of UHPC after chloride induced corrosion. When the initial crack width was less than 0.1 mm, two kinds of UHPC showed the ideal residual flexural behavior rate after a 150-cycle corrosion, which exceeded 95 %, owing to the self-healing of initial crack caused by the further hydration of unreacted binders in UHPC matrix. When the initial crack width was near 0.2 mm and 0.3 mm, after a 150-cycle corrosion, the flexural strength of UHPC with BFRP minibars was decreased by 10.94 % and 12.99 %, the decrease rate was 59.72 % and 52.24 % lower than UHPC with steel fibers in same environment, respectively. The similar changes in toughness and stiffness were found too. It indicated that using BFRP minibars to reinforce UHPC effectively alleviated the risk of decrease in mechanical properties of pre-cracked UHPC caused by steel fiber corrosion under harsh environment.
引用
收藏
页数:16
相关论文
共 35 条
  • [31] Effects of High Temperature and Water Re-Curing on the Flexural Behavior and Mechanical Properties of Steel-Basalt Hybrid Fiber-Reinforced Concrete
    Celik, Zinnur
    Urtekin, Yunus
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [32] Chloride-induced corrosion of steel fiber near the surface of ultra-high performance concrete and its effect on flexural behavior with various thickness
    Pyo, Sukhoon
    Koh, Taehoon
    Tafesse, Million
    Kim, Hyeong-Ki
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 224 : 206 - 213
  • [33] Enhancing bonding behavior between basalt fiber-reinforced polymer sheets and concrete using resin pre-coating method and multi-wall carbon nanotubes
    Shi, Changchun
    Jin, Shengji
    Jin, Bang
    Xu, Jingyan
    JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [34] Experimental study on the effects of dynamic loading and seawater attack on bond behavior between basalt fiber reinforced polymer bars and seawater sea-sand concrete
    Li, Sheng
    Zhu, Deju
    Guo, Shuaicheng
    Yi, Yong
    Feng, Guangyan
    JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [35] Bond Behavior between Basalt Fiber-Reinforced Polymer Sheet and Concrete Substrate under the Coupled Effects of Freeze-Thaw Cycling and Sustained Load
    Shi, Jiawei
    Zhu, Hong
    Wu, Zhishen
    Seracino, Rudolf
    Wu, Gang
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (04) : 530 - 542