Effects of basalt fiber reinforced polymer minibars on the flexural behavior of pre-cracked UHPC after chloride induced corrosion

被引:8
|
作者
Chen, Zhiyuan [1 ]
Wang, Xin [1 ]
Ding, Lining [2 ]
Niu, Fusheng [3 ,4 ]
Jiang, Kaidi [1 ]
Wang, Hua [3 ,4 ]
Wu, Zhishen [1 ]
机构
[1] Southeast Univ, Natl & Local Unified Engn Res Ctr Basalt Fiber Pro, Key Lab C & PC Struct, Minist Educ, Nanjing 211189, Peoples R China
[2] Nanjing Forestry Univ, Sch Civil Engn, Nanjing 210037, Peoples R China
[3] China Railway Tunnel Grp Co Ltd, Guangzhou 511458, Peoples R China
[4] Guangdong Prov Key Lab Intelligent Monitoring & Ma, Guangzhou 511458, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
UHPC; BFRP minibar; Steel fiber; Chloride induced corrosion and long-term; flexural behavior; HIGH PERFORMANCE CONCRETE; STEEL FIBER; MECHANICAL-PROPERTIES; SHAPE;
D O I
10.1016/j.jobe.2023.108382
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ultra-high performance concrete (UHPC) exhibits high shrinkage, which results in a severe risk of cracking in practice, leading to the risk of long-term mechanical performance degradation caused by steel fiber corrosion in harsh environment. This study aims to use basalt fiber reinforced polymer (BFRP) minibars to improve the long-term flexural behavior of UHPC. UHPC reinforced with 3 % BFRP minibars and 3 % steel fibers were pretreated for initial crack and cured in chloride solution for various dry-wet cycles, respectively. The long-term tensile behavior of BFRP minibar and steel fiber, and long-term flexural behavior of UHPC with BFRP minibars and steel fibers were systematically tested and evaluated before and after corrosion, respectively. Ac-cording to the test results, compared to steel fiber, BFRP minibar showed a much better chloride resistance, leading to a great improvement in long-term flexural behavior of UHPC after chloride induced corrosion. When the initial crack width was less than 0.1 mm, two kinds of UHPC showed the ideal residual flexural behavior rate after a 150-cycle corrosion, which exceeded 95 %, owing to the self-healing of initial crack caused by the further hydration of unreacted binders in UHPC matrix. When the initial crack width was near 0.2 mm and 0.3 mm, after a 150-cycle corrosion, the flexural strength of UHPC with BFRP minibars was decreased by 10.94 % and 12.99 %, the decrease rate was 59.72 % and 52.24 % lower than UHPC with steel fibers in same environment, respectively. The similar changes in toughness and stiffness were found too. It indicated that using BFRP minibars to reinforce UHPC effectively alleviated the risk of decrease in mechanical properties of pre-cracked UHPC caused by steel fiber corrosion under harsh environment.
引用
收藏
页数:16
相关论文
共 35 条
  • [1] Experimental and numerical investigation on the deflection behavior of pre-cracked and repaired reinforced concrete beams with fiber-reinforced polymer
    Hamrat, Mostefa
    Bouziadi, Farid
    Boulekbache, Bensaid
    Daouadji, Tahar Hassaine
    Chergui, Selma
    Labed, Abderahim
    Amziane, Sofiane
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 249
  • [2] Investigation of the Flexural Behavior of Preloaded and Pre-Cracked Reinforced Concrete Beams Strengthened with CFRP Plates
    Samarakoon, S. M. Samindi M. K.
    Piatek, Bartosz
    De Silva, G. H. M. J. Subashi
    MATERIALS, 2023, 16 (01)
  • [3] Flexural Behavior of Basalt Fiber Reinforced Polymer Tube Confined Coconut Fiber Reinforced Concrete
    Lv, Yang
    Wu, Xueqian
    Gao, Mengran
    Chen, Jiaxin
    Zhu, Yuhao
    Cheng, Quanxi
    Chen, Yu
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
  • [4] Study of the flexural behavior of basalt fiber-reinforced concrete beams with basalt fiber-reinforced polymer bars and steel bars
    Wei, Zhiwei
    Wang, Tongshuai
    Li, Hongjie
    Dong, Tangchun
    Li, Zhihua
    Guo, Xuan
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2025, 22
  • [5] Research on flexural behavior of damaged RC beams strengthened with basalt fiber reinforced polymer
    Wang, Hailiang
    Yuan, Xinglong
    RESEARCH IN MATERIALS AND MANUFACTURING TECHNOLOGIES, PTS 1-3, 2014, 835-836 : 762 - 767
  • [6] Experimental Study on Carbon Fiber Reinforced Polymer Strengthened Pre-Cracked Box Girders with Corrugated Steel Web
    Dong, Jiang-Feng
    Yuan, Shu-Cheng
    Yuan, Shi-Lei
    Wang, Qing-Yuan
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (17) : 5541 - 5545
  • [7] Flexural behavior of pre-damaged UHPC-HPC composite beams in chloride corrosion environment
    Mei K.-H.
    Kang W.-B.
    Liu Y.
    Lu D.-L.
    Sun S.-J.
    Han F.-Y.
    Wu Y.-C.
    Jiaotong Yunshu Gongcheng Xuebao/Journal of Traffic and Transportation Engineering, 2024, 24 (01): : 117 - 130
  • [8] Effects of Accelerated Weathering on Degradation Behavior of Basalt Fiber Reinforced Polymer Nanocomposites
    Hashim, Ummu Raihanah
    Jumahat, Aidah
    Jawaid, Mohammad
    Dungani, Rudi
    Alamery, Salman
    POLYMERS, 2020, 12 (11) : 1 - 16
  • [9] Serviceability and Flexural Behavior of Concrete Beams Reinforced with Basalt Fiber-Reinforced Polymer (BFRP) Bars Exposed to Harsh Conditions
    Alkhraisha, Hakem
    Mhanna, Haya
    Tello, Noor
    Abed, Farid
    POLYMERS, 2020, 12 (09)
  • [10] Experimental research on the flexural behavior of Basalt fiber-reinforced polymer (BFRP) and steel bars hybrid reinforced concrete beams
    Wei, Bingyan
    He, Xiongjun
    Chen, Tao
    Wu, Chao
    Wang, Huayi
    STRUCTURAL CONCRETE, 2024, : 837 - 855