Virtual registration of comminuted bone fracture and preoperative assessment of reconstructed bone model using the Procrustes algorithm based on CT dataset

被引:1
|
作者
Arumugam, Senthilmurugan [1 ,3 ]
Ranganathan, Rajesh [1 ]
Narayanasamy, Venkatesh Kumar [2 ]
机构
[1] Coimbatore Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[2] PSG Inst Med Sci & Res, Dept Orthopaed & Trauma, Coimbatore, Tamil Nadu, India
[3] Coimbatore Inst Technol, Dept Mech Engn, Avinashi Rd, Coimbatore 641014, Tamil Nadu, India
关键词
Bone reconstruction; virtual bone reduction process; comminuted bone fracture; segmentation techniques; iterative closest point; Procrustes algorithm; SURGERY; REDUCTION; SIMULATION;
D O I
10.1177/09544119231221192
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A research work was undergone in a virtual bone reduction process for reconstruction of the comminuted pelvic bone fracture using a CT scan dataset of patients. This includes segmentation, 3D model optimization and bone registration technique. The accuracy of the reconstructed bone model was validated using Finite Element Method. Analysed and applied various segmentation techniques to segregate the injured bone structure. The ICP (Iterative Closest Point), Procrustes algorithm and Canny edge detection algorithm were applied to understand the bone registration process for surgery in detail. The average RMS error, mean absolute distance, mean absolute deviation, and mean signed distance of the reconstructed bone model using proposed algorithms involving 10 patient datasets in a group were found to be 1.77, 1.48, 1.51 and -0.31 mm respectively. The calculated RMS error value proved minimal error in semi-automatic registration than other existing automatic registration techniques. Therefore, the proposed approach is suitable for virtual bone reduction for comminuted pelvic bone fracture. This method could also be implemented for various other bone fracture reconstruction requirements.
引用
收藏
页码:219 / 236
页数:18
相关论文
共 50 条
  • [21] Potential for Early Fracture Risk Assessment in Patients with Metastatic Bone Disease Using Parametric Response Mapping of CT Images
    Hoff, Benjamin A.
    Toole, Michael
    Yablon, Corrie
    Ross, Brian D.
    Luker, Gary D.
    Van Poznak, Catherine
    Galban, Craig J.
    TOMOGRAPHY, 2015, 1 (02) : 98 - 104
  • [22] Effects of CT threshold value to make a surface bone model on accuracy of shape-based registration in a CT-based navigation system for hip surgery
    Sugano, N
    Sasama, T
    Nakajima, Y
    Sato, Y
    Nishii, T
    Iida, T
    Nakagawa, K
    Ono, K
    Nishii, T
    Nishihara, S
    Tamura, S
    Yonenobu, K
    Ochi, T
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 306 - 311
  • [23] Improving ultrasound-based bone registration using the iterative closest point algorithm paired with a complex optimization solver
    Theodorakos, Ilias
    Andersen, Michael Skipper
    MEDICAL ENGINEERING & PHYSICS, 2024, 126
  • [24] Association between metabolic syndrome and bone fracture risk A community-based study using a fracture risk assessment tool
    Yu, Chia-Ying
    Chen, Fang-Ping
    Chen, Li-Wei
    Kuo, Sheng-Fong
    Chien, Rong-Nan
    MEDICINE, 2017, 96 (50)
  • [25] Assessment of the risk factors for impending fractures following radiotherapy for long bone metastases using CT scan-based virtual simulation: a retrospective study
    Tatar, Zuzana
    Soubrier, Martin
    Dillies, Anne Francoise
    Verrelle, Pierre
    Boisgard, Stephane
    Lapeyre, Michel
    RADIATION ONCOLOGY, 2014, 9 : 227
  • [26] Assessment of the risk factors for impending fractures following radiotherapy for long bone metastases using CT scan-based virtual simulation: a retrospective study
    Zuzana Tatar
    Martin Soubrier
    Anne Françoise Dillies
    Pierre Verrelle
    Stéphane Boisgard
    Michel Lapeyre
    Radiation Oncology, 9
  • [27] Assessment of Bone Quality using Finite Element Analysis Based upon Micro-CT Images
    Rhee, Yumie
    Hur, June-Huyck
    Won, Ye-Yeon
    Lim, Sung-Kil
    Beak, Myong-Hyun
    Cui, Wen-Quan
    Kim, Kwang-Gyoun
    Kim, Young Eun
    CLINICS IN ORTHOPEDIC SURGERY, 2009, 1 (01) : 40 - 47
  • [28] Biomechanical comparison between double-plate fixation and posterior plate fixation for comminuted olecranon fracture using two triceps screws in synthetic bone model
    Lee, Yohan
    Cho, Bong Wan
    Kim, Min Bom
    Lee, Young Ho
    MEDICINE, 2022, 101 (01) : E28313
  • [29] Quantitative assessment of femoral head ischemia using two-phase bone SPECT/CT in patients with proximal femoral fracture
    Iwata, K.
    Fukushima, Y.
    Kumita, S.
    Hamana, T.
    Hashimoto, H.
    Sugihara, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S489 - S489
  • [30] A personalized preoperative modeling system for internal fixation plates in long bone fracture surgery-A straightforward way from CT images to plate model
    Liu, Bin
    Zhang, Song
    Zhang, Jianxin
    Xu, Zhao
    Chen, Yanjie
    Liu, Shujun
    Qi, Wen
    Yang, Liang
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2019, 15 (05):