Impact of monocular vs. binocular contrast and blur on the range of functional stereopsis

被引:0
|
作者
Lew, Wei Hau [1 ,2 ]
Coates, Daniel R. [1 ]
机构
[1] Univ Houston, Coll Optometry, Houston, TX USA
[2] Univ Houston, Coll Optometry, 4901 Calhoun Rd, Houston, TX 77004 USA
关键词
Stereopsis; Upper disparity limit; Range of disparity; Contrast; Blur; Stereo-matching algorithm; SPATIAL-FREQUENCY; DEPTH DISCRIMINATION; SENSITIVITY FUNCTION; D-MAX; DISPARITY; LUMINANCE; FUSION; ACUITY; PERCEPTION; STEREOACUITY;
D O I
10.1016/j.visres.2023.108309
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Stereopsis depends on the smallest stereo threshold (lower limit) and the upper fusion limit. While studies have shown that the lower limit worsens with reduced contrast and blur, more strongly in monocular than in binocular conditions, the effect on the upper limit remains uncertain. Here, we assess the impact of contrast and blur on the range of the disparity sensitivity function (DSF) in a stereo letter recognition task. Subjects had to identify the stereo letters embedded in a random dot stereogram, and adaptive staircases were used to estimate the two limits. Five subjects performed the experiment at baseline contrast (100%), with different contrast (32% and 10%) and blur (+0.75DS and +1.25DS) in monocular and binocular degradation. We proposed three possible outcomes: 1) the range collapses in both directions 2) the lower limit threshold reduces, but the upper limit is not affected 3) the threshold for both limits increases and the range remains the same. We found that the curve for both limits was lowpass in shape, resulting in a smaller range at higher SFs. The results were similar to the first prediction, where the threshold for the lower limit increased while the upper limit was reduced at lower contrast and higher blur. The shrinkage of DSF is significant in monocular conditions. However, with blur, there was inter-subject variability. A simple cross-correlation stereo-matching algorithm was used to quantify the effect of contrast and blur. The results were consistent with the behavioral result that the range of DSF decreases with image degradation.
引用
收藏
页数:12
相关论文
共 44 条
  • [41] Functional outcomes before and after implant removal in patients with posttraumatic shoulder stiffness and healed proximal humerus fractures: does implant material (PEEK vs. titanium) have an impact? – a pilot study
    E. Fleischhacker
    C. M. Sprecher
    S. Milz
    M. M. Saller
    J. Gleich
    G. Siebenbürger
    T. Helfen
    W. Böcker
    B. Ockert
    BMC Musculoskeletal Disorders, 23
  • [42] Desalination of marginal water: environmental and cost impact Part 1: The effect on long-range regional development Part 2: Case studies of desalinated water vs. local desalination of marginal brackish water
    Glueckstern, P
    Nadav, N
    Priel, M
    DESALINATION, 2001, 138 (1-3) : 157 - 163
  • [43] Impact of preoperative [18F]FDG PET/CT vs. contrast-enhanced CT in the staging and survival of patients with clinical stage I and II non-small cell lung cancer: a 10-year follow-up study
    Jun-Tao Lin
    Xiang-Meng Li
    Wen-Zhao Zhong
    Qing-Yi Hou
    Chun-Ling Liu
    Xin-Yue Yu
    Kai-Yan Ye
    Yi-Lu Cheng
    Jia-Yu Du
    Yun-Qing Sun
    Fu-Gui Zhang
    Hong-Hong Yan
    Ri-Qiang Liao
    Song Dong
    Ben-Yuan Jiang
    Si-Yang Liu
    Yi-Long Wu
    Xue-Ning Yang
    Annals of Nuclear Medicine, 2024, 38 : 188 - 198
  • [44] Impact of preoperative [18F]FDG PET/CT vs. contrast-enhanced CT in the staging and survival of patients with clinical stage I and II non-small cell lung cancer: a 10-year follow-up study
    Lin, Jun-Tao
    Li, Xiang-Meng
    Zhong, Wen-Zhao
    Hou, Qing-Yi
    Liu, Chun-Ling
    Yu, Xin-Yue
    Ye, Kai-Yan
    Cheng, Yi-Lu
    Du, Jia-Yu
    Sun, Yun-Qing
    Zhang, Fu-Gui
    Yan, Hong-Hong
    Liao, Ri-Qiang
    Dong, Song
    Jiang, Ben-Yuan
    Liu, Si-Yang
    Wu, Yi-Long
    Yang, Xue-Ning
    ANNALS OF NUCLEAR MEDICINE, 2024, 38 (03) : 188 - 198