Numerical analysis of cold energy release process of cold storage plate in a container for temperature control

被引:4
|
作者
Gou, Jiaming [1 ,2 ,3 ]
Lin, Jicheng [1 ,2 ]
Jiang, Yihong [1 ,2 ]
Mei, Shuang [1 ]
Xia, Jingjing [1 ]
Lin, Shitao [1 ,2 ]
Zhang, Xiaodan [1 ,2 ]
Shen, Qunyu [4 ]
Cai, Wei [1 ,2 ]
Liang, Jianhua [1 ,2 ]
Lu, Enli [1 ,2 ,3 ]
机构
[1] South China Agr Univ, Coll Engn, Guangzhou 510642, Peoples R China
[2] Minist Educ, Key Lab Key Technol Agr Machine & Equipment, Guangzhou 510642, Peoples R China
[3] Minist Agr & Rural Affairs, South China Smart Agr Publ Res & Dev Ctr, Guangzhou 510000, Peoples R China
[4] Columbia Univ, Fu Fdn Sch Engn & Appl Sci, New York, NY 10027 USA
基金
美国国家科学基金会;
关键词
Computational Fluid Dynamics (CFD); Cold storage plate; Cold storage container; Melting rate; PHASE-CHANGE MATERIAL; SIMULATION; PCM; PERFORMANCE; CHAIN; MODEL;
D O I
10.1016/j.est.2023.108230
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increasing need for sustainable and environmentally friendly cooling systems with low emissions has driven the advancement of cold storage technology utilizing phase change material (PCM) for efficient cold energy storage. However, the transportation and monitoring of cold energy status in the container remain challenging, affecting the temperature control of the stored products. To address this problem, this study developed a numerical model using Computational Fluid Dynamics (CFD) to analyze the impact of inlet velocity (1.8, 2.4, 3.0, 3.6 and 4.2 m/s) and spacing of the cold storage plate (10, 20 and 30 mm) on the release of cold energy. To validate the accuracy of the numerical model, experiments were conducted, and the results showed good agreement with the predicted values. The study demonstrated that increasing the inlet velocity improves the melting rate from 0.0443 to 0.1064. However, this also resulted in greater differences in the melting rates among the cold storage plates in various locations with poor melting uniformity (uniformity index increases from 0.055 to 0.084 with increasing velocity). On the other hand, increasing the spacing of the cold storage plates was found to reduce the outlet temperature and improve the melting rate and uniformity. The study also showed that the increase in spacing facilitated the maintenance of low temperatures at the outlet for a long time (prolong time from 69 min to 115 min). This study provides quantitative parameters and insights that can guide the design and optimization of cold storage systems.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Thermal analysis of a cold rolling process - A numerical approach
    Khan, OU
    Jamal, A
    Arshed, GM
    Arif, AFM
    Zubair, SM
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2004, 46 (06) : 613 - 632
  • [22] Design and analysis of a flooded tube for cold energy storage
    Sait, Hani Hussain
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 94 : 151 - 160
  • [23] Design and Test of Passive Cold Storage Temperature Control Box
    Li B.
    Shen H.
    Guo J.
    Wei X.
    Lü E.
    Yuan J.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2020, 51 (09): : 358 - 365
  • [24] Numerical Simulation Analysis of Heat Storage and Release Performance in Baffle plate Phase Change Energy Storage Tank
    Li, HuiXing
    Sun, Hao
    Feng, GuoHui
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3334 - 3339
  • [25] Numerical analysis of doublet wells for cold energy storage on heat damage treatment in deep mines
    School of Mechanic and Civil Engineering, China University of Mining and Technology, Beijing 100083, China
    不详
    J. China Univ. Min. Technol., 2006, 3 (278-282):
  • [26] Cold thermal energy storage for milk chilling: A numerical and experimental study
    Prakash, Ravi
    Ravindra, Menon Rekha
    JOURNAL OF FOOD ENGINEERING, 2023, 337
  • [28] Thermal Expansion Investigation of Liquid Cold Plate with Varying Ambient Temperature at Storage
    Parlak, Murat
    Yagci, Vedat
    PROCEEDINGS OF THE 17TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2018), 2018, : 1333 - 1338
  • [29] Impact of control strategies on energy consumption in cold storage facilities
    Niu, Heng
    Wang, Baolong
    Yang, Zixu
    Liu, Xinyi
    Liu, Xinghua
    Shi, Wenxing
    ENERGY AND BUILDINGS, 2024, 322
  • [30] Numerical Simulation of Small Cold Storage
    Zhong, Xiaohui
    Zhai, Yuling
    Gou, Yujun
    INTELLIGENT STRUCTURE AND VIBRATION CONTROL, PTS 1 AND 2, 2011, 50-51 : 896 - +