Numerical analysis of cold energy release process of cold storage plate in a container for temperature control

被引:4
|
作者
Gou, Jiaming [1 ,2 ,3 ]
Lin, Jicheng [1 ,2 ]
Jiang, Yihong [1 ,2 ]
Mei, Shuang [1 ]
Xia, Jingjing [1 ]
Lin, Shitao [1 ,2 ]
Zhang, Xiaodan [1 ,2 ]
Shen, Qunyu [4 ]
Cai, Wei [1 ,2 ]
Liang, Jianhua [1 ,2 ]
Lu, Enli [1 ,2 ,3 ]
机构
[1] South China Agr Univ, Coll Engn, Guangzhou 510642, Peoples R China
[2] Minist Educ, Key Lab Key Technol Agr Machine & Equipment, Guangzhou 510642, Peoples R China
[3] Minist Agr & Rural Affairs, South China Smart Agr Publ Res & Dev Ctr, Guangzhou 510000, Peoples R China
[4] Columbia Univ, Fu Fdn Sch Engn & Appl Sci, New York, NY 10027 USA
基金
美国国家科学基金会;
关键词
Computational Fluid Dynamics (CFD); Cold storage plate; Cold storage container; Melting rate; PHASE-CHANGE MATERIAL; SIMULATION; PCM; PERFORMANCE; CHAIN; MODEL;
D O I
10.1016/j.est.2023.108230
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increasing need for sustainable and environmentally friendly cooling systems with low emissions has driven the advancement of cold storage technology utilizing phase change material (PCM) for efficient cold energy storage. However, the transportation and monitoring of cold energy status in the container remain challenging, affecting the temperature control of the stored products. To address this problem, this study developed a numerical model using Computational Fluid Dynamics (CFD) to analyze the impact of inlet velocity (1.8, 2.4, 3.0, 3.6 and 4.2 m/s) and spacing of the cold storage plate (10, 20 and 30 mm) on the release of cold energy. To validate the accuracy of the numerical model, experiments were conducted, and the results showed good agreement with the predicted values. The study demonstrated that increasing the inlet velocity improves the melting rate from 0.0443 to 0.1064. However, this also resulted in greater differences in the melting rates among the cold storage plates in various locations with poor melting uniformity (uniformity index increases from 0.055 to 0.084 with increasing velocity). On the other hand, increasing the spacing of the cold storage plates was found to reduce the outlet temperature and improve the melting rate and uniformity. The study also showed that the increase in spacing facilitated the maintenance of low temperatures at the outlet for a long time (prolong time from 69 min to 115 min). This study provides quantitative parameters and insights that can guide the design and optimization of cold storage systems.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dynamic Simulation and Analysis of the Process of Cold-storage Plate Release Cool in Refrigerator Vehicle
    Li, Xiao Yan
    Du, Shi Qiang
    Li, Yue Ming
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 589 - 592
  • [2] Numerical analysis of cold rolling process of thin plate workpieces
    Canadija, M
    STROJARSTVO, 2000, 42 (5-6): : 197 - 203
  • [3] Cold Storage and Release Characteristics of Phase Change Cold Storage Plate with Non-Uniform Fins
    Wu, Kun
    Zhao, Haibo
    Wang, Ye
    ENERGIES, 2024, 17 (15)
  • [4] Temperature Control System of Cold Storage
    Lu, Ting
    Liu, Zeliang
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL CONTROL TECHNOLOGY AND TRANSPORTATION, 2015, 41 : 1 - 6
  • [5] System Performance and Economic Analysis of a Phase Change Material Based Cold Energy Storage Container for Cold Chain Transportation
    Zhang, Jianwu
    Li, Zixiao
    Tong, Shanhu
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2022, 2022
  • [6] Acceleration the solidification process of cold-thermal storage/ nanoparticles using finned container: A numerical study
    Milyani, Ahmad H.
    Abu-Hamdeh, Nidal H.
    Azhari, Abdullah A.
    AL-bonsrulah, Hussein A. Z.
    Alghawli, Abed Saif
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 51
  • [7] Simulation Study on Temperature Field and Cold Plate Melting of Cold Storage Refrigerator Car
    Xu Xiaofeng
    Zhang Xuelai
    Munyalo, Jotham Muthoka
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 3394 - 3400
  • [8] Concentrated solar energy system and cold thermal energy storage (process development and energy analysis)
    Ghorbani, Bahram
    Mehrpooya, Mehdi
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 37
  • [9] Concentrated solar energy system and cold thermal energy storage (process development and energy analysis)
    Ghorbani, Bahram
    Mehrpooya, Mehdi
    Sustainable Energy Technologies and Assessments, 2020, 37
  • [10] Parameter optimization on convective heat transfer of cold plate for cold storage temperature control box based on multi-parameter coupling
    Guo J.
    Wu X.
    Lin S.
    Zeng Z.
    Shen H.
    Wei X.
    Lyu E.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2021, 37 (19): : 228 - 235