Test and characterization of SiPMs for the upgrade of MEGII high resolution Timing Counter

被引:0
|
作者
Rossella, M. [1 ]
Cattaneo, P. W. [1 ]
de Bari, A. [2 ]
Boca, G. [2 ]
Prata, M. C.
de Vecchi, C.
Boffelli, F. [1 ,2 ]
Nardo, R.
Barnaba, O. [1 ,2 ]
机构
[1] INFN, Sez Pavia, Via Bassi 6, I-27100 Pavia, Italy
[2] Univ Pavia, Dipartimento Fis, Via Bassi 6, I-27100 Pavia, Italy
关键词
Particle tracking detectors; Photon detectors for UV; visible and IR photons (solid-state) (PIN diodes; APDs; Si-PMTs; G-APDs; CCDs; EBCCDs; EMCCDs; CMOS imagers; etc); Timing detectors;
D O I
10.1088/1748-0221/19/03/C03004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The MEG II experiment based at PSI (Zuerich, Switzerland) has been committed and is taking data since 2021 to improve sensitivity on the decay mu(+) -> e(+) gamma. The pixelated Timing Counter (pTC), consisting of two arrays of 512 5 mm thick scintillator pixel each, read out by 6 3x3 mm(2), 50 mu m cell, Silicon Photomultipliers (SiPMs) from AdvanSiD, for a total of 6144 SiPM, achieves an overall resolution in the positron impact time of similar to 43 ps when exploiting multiple measurements. To additionally improve this resolution, 4x4 mm(2), 40 mu m cell SiPMs have been selected to substitute a fraction of the old ones (about 1000 of them overall). By means of an automated test system, a first group of them has been characterized (measuring their breakdown voltage and their I-V curves), to match as much as possible SiPMs with the same gains in each pixel, in order to maximize the pixel time resolution. Such automated test system will be presented, together with some preliminary results on single pixel time resolution and the expectations of the average time resolution of the pTC in the coming years.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Test and characterisation of SiPMs for the MEGII high resolution Timing Counter
    Simonetta, M.
    Biasotti, M.
    Boca, G.
    Cattaneo, P. W.
    De Gerone, M.
    Gatti, F.
    Nardo, R.
    Nishimura, M.
    Ootani, W.
    Pizzigoni, G.
    Prata, M. C.
    Rossella, M.
    Shibata, N.
    Uchiyama, Y.
    Yoshida, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 145 - 147
  • [2] Radiation Hardness Tests With Neutrons of Timing Counter MEGII SiPMs
    Cervi, T.
    Bariani, S.
    Cattaneo, P. W.
    Oddone, M.
    Prata, M. C.
    Prata, M.
    Romano, E.
    Rossella, M.
    Simonetta, M.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [3] Design and test of the calibration system of the MEGII Pixelated Timing Counter
    Cattaneo, P. W.
    Boca, G.
    De Geronee, M.
    Gattie, F.
    Nakao, M.
    Nishimura, M.
    Ootani, W.
    Rossella, M.
    Uchiyama, Y.
    Usami, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 300 - 302
  • [4] Timing resolution of a plastic scintillator counter read out by radiation damaged SiPMs connected in series
    Boca, G.
    Cattaneo, P. W.
    De Gerone, M.
    Gatti, F.
    Nakao, M.
    Nishimura, M.
    Ootani, W.
    Rossella, M.
    Uchiyama, Y.
    Usami, M.
    Yanai, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 999
  • [5] Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results
    De Gerone, M.
    Gatti, F.
    Ootani, W.
    Uchiyama, Y.
    Nishimura, M.
    Shirabe, S.
    Cattaneo, P. W.
    Rossella, M.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [6] A High Resolution Timing Counter for the MEG II Experiment
    Simonetta, M.
    Boca, G.
    Cattaneo, P. W.
    De Gerone, M.
    Gatti, F.
    Ootani, W.
    Pizzigoni, G.
    Rossella, M.
    Shibata, N.
    Uchiyama, Y.
    Yoshida, K.
    Nishimura, M.
    Nakao, M.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [7] A high resolution Timing Counter for the MEG II experiment
    De Gerone, M.
    Bevilacqua, A.
    Biasotti, M.
    Boca, G.
    Cattaneo, P. W.
    Gatti, F.
    Nishimura, M.
    Ootani, W.
    Pizzigoni, G.
    Rossella, M.
    Shibata, N.
    Siccardi, F.
    Simonetta, M.
    Uchiyama, Y.
    Yoshida, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 92 - 95
  • [8] Radiation damage effect on time resolution of 6 series-connected SiPMs for MEG II positron timing counter
    Usami, M.
    Boca, G.
    Cattaneo, P. W.
    De Gerone, M.
    Gatti, F.
    Nakao, M.
    Nishimura, M.
    Ootani, W.
    Rossella, M.
    Uchiyama, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 572 - 573
  • [9] Design considerations for a new generation of SiPMs with unprecedented timing resolution
    Enoch, S.
    Gola, A.
    Lecoq, P.
    Rivetti, A.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)
  • [10] Timing Resolution Improvements from Cooling in BGO PET Detection with Analog SiPMs
    McVea, Andrew
    Kao, Chien-Min
    Chen, Chin-Tu
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,