Abundant Cyanobacteria in Autumn Adhering to the Heating, Ventilation, and Air-Conditioning (HVAC) in Shanghai

被引:2
|
作者
Nie, Changliang [1 ]
Geng, Xueyun [1 ]
Zhang, Runqi [1 ]
Wang, Lina [1 ]
Li, Ling [1 ]
Chen, Jianmin [1 ,2 ,3 ]
机构
[1] Fudan Univ, Dept Environm Sci & Engn, Shanghai Key Lab Atmospher Particle Pollut & Preve, Natl Observat & Res Stn Wetland Ecosyst Yangtze Es, Shanghai 200438, Peoples R China
[2] Fudan Univ, Inst Atmospher Sci, IRDR Int Ctr Excellence Risk Interconnect & Govern, Shanghai 200438, Peoples R China
[3] Inst Ecochongming IEC, Shanghai 200062, Peoples R China
关键词
season; cyanobacteria; cyanosphere; indoor environment; heating; ventilation; air-conditioning (HVAC); BACTERIAL COMMUNITIES; NODULARIA-SPUMIGENA; WATER; PHYTOPLANKTON; SEDIMENTATION; BUILDINGS; MECHANISM; TOXICITY; SYSTEMS; GROWTH;
D O I
10.3390/microorganisms11071835
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Cyanobacteria are ever-present, mainly flourishing in aquatic environments and surviving virtually in other habitats. The microbiota of indoor dust on the pre-filter of heating, ventilation, and air-conditioning (HVAC) systems, which reflect indoor microbial contamination and affect human health, has attracted attention. Contemporary studies on cyanobacteria deposited on the pre-filter of HVAC remain scant. By the culture-independent approach of qPCR and high throughput sequencing technologies, our results documented that the cyanobacterial concentrations were highest in autumn, occurred recurrently, and were about 2.60 and 10.57-fold higher than those in winter and summer. We proposed that aquatic and terrestrial cyanobacteria contributed to the pre-filter of HVAC by airborne transportation produced by wave breaks, bubble bursts, and soil surface by wind force, owing to the evidence that cyanobacteria were commonly detected in airborne particulate matters. The cyanobacteria community structure was characterized in Shanghai, where Chroococcidiopsaceae, norank_cyanobacteriales, Nostocaceae, Paraspirulinaceae, and others dominated the dust on the pre-filter of HVAC. Some detected genera, including Nodularia sp., Pseudanabaena sp., and Leptolyngbya sp., potentially produced cyanobacterial toxins, which need further studying to determine their potential threat to human health. The present work shed new insight into cyanobacteria distribution in the specific environment besides aquatic habitats.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Toward Failure Mode and Effect Analysis for Heating, Ventilation and Air-Conditioning
    Yang, Chunsheng
    Shen, Weiming
    Chen, Qiangqiang
    Gunay, Burak
    2017 IEEE 21ST INTERNATIONAL CONFERENCE ON COMPUTER SUPPORTED COOPERATIVE WORK IN DESIGN (CSCWD), 2017, : 408 - 413
  • [32] Thermodynamics and economics of liquid desiccants for heating, ventilation and air-conditioning - An overview
    Giampieri, Alessandro
    Ma, Zhiwei
    Smallbone, Andrew
    Roskilly, Anthony Paul
    APPLIED ENERGY, 2018, 220 : 455 - 479
  • [33] Discrete-event diagnostics of Heating, Ventilation, and Air-Conditioning Systems
    Sinnamohideen, K
    PROCEEDINGS OF THE 2001 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2001, : 2072 - 2076
  • [34] Mobile Inspection Robot for Heating, Ventilation and Air Conditioning (HVAC) Ducting Systems
    Hisham, Amirah Aisha Badrul
    Xuan, Wong Liang
    Ishak, Mohamad Hafis Izran
    Idris, Nurul Hawani
    Nawi, Abdullah Mohd
    JURNAL TEKNOLOGI, 2015, 73 (06):
  • [35] Removal of submicron particles using a carbon fiber ionizer-assisted medium air filter in a heating, ventilation, and air-conditioning (HVAC) system
    Park, Jae Hong
    Yoon, Ki Young
    Hwang, Jungho
    BUILDING AND ENVIRONMENT, 2011, 46 (08) : 1699 - 1708
  • [36] Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems
    Möritz, M
    Peters, H
    Nipko, B
    Rüden, H
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2001, 203 (5-6) : 401 - 409
  • [37] VENTILATION AND AIR-CONDITIONING - A PRIMER FOR NONENGINEERS
    MALLISON, GF
    AMERICAN JOURNAL OF INFECTION CONTROL, 1984, 12 (03) : 200 - 203
  • [38] Ventilation and Air-conditioning Technology and Comfort
    Mueller, D.
    Streblow, R.
    WOHLFUHLEN DURCH RAUMLUFTTECHNIK, 2010, 2091 : 29 - 35
  • [39] Introduction on heating, ventilation and air-conditioning design for the terminals of Beijing Airport in China
    Xia, Lingcao
    Huang, Jiyi
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 95 - 101
  • [40] Heat-/ventilation engineering. Dimensioning of heating and air-conditioning systems
    Vajda, József
    HLH Heizung Luftung/Klima Haustechnik, 1999, 50 (12): : 34 - 36