Multiperson Respiratory Monitoring Using Single-Channel Continuous-Wave Radar With Time Modulated Array

被引:5
|
作者
Guan, Lei [1 ]
Wu, Tong [2 ]
Yang, Xiaodong [1 ]
Zhao, Nan [1 ]
Zhang, Zhiya [3 ]
Alomainy, Akram [4 ]
Imran, Muhammad Ali [5 ]
Abbasi, Qammer H. [5 ]
机构
[1] Xidian Univ, Sch Elect Engn, Key Lab High Speed Circuit Design & EMC, Minist Educ, Xian 710071, Shaanxi, Peoples R China
[2] Xidian Univ, Sch Elect Engn, Xian 710071, Shaanxi, Peoples R China
[3] Xidian Univ, Natl Key Lab Sci & Technol Microwave & Antenna, Xian 710071, Shaanxi, Peoples R China
[4] Queen Mary Univ London, Sch Elect Engn & Comp Sci, London E1 4NS, England
[5] Univ Glasgow, James Watt Sch Engn, Glasgow G12 8QQ, Scotland
基金
中国国家自然科学基金;
关键词
Multiperson; respiratory monitoring; time mod-ulated array (TMA); VITAL-SIGN; HEART-RATE; LOCALIZATION;
D O I
10.1109/TIM.2023.3287258
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radio frequency (RF) signals are widely used in respiratory detection due to their non-contact, remote sensing advantages. In order to satisfy multiperson monitoring, the existing RF sensing system greatly increases the complexity of the feeder network, which will affect the stability of the system and have high maintenance costs. In this study, we propose a single-channel, low-complexity multiperson respiratory monitoring system. It uses a time-modulated array (TMA) to detect the position and respiration rate of multiple targets. The TMA is reconstructed into a conventional multichannel array by the harmonic recovery method. Beamforming is used to scan the scene horizontally. At the same time, the beamformed signal is converted to the frequency domain to construct the angle of arrival-frequency map (AFM). By forming a beam pointing to the target, the time domain respiration signal of each target can be acquired. The experimental results show that the maximum respiratory rate (RR) estimation errors of the proposed system in single-person, two-person, and three-person scenarios are 0.77, 0.96, and 1.32 bmp, respectively. In addition, the Bland-Altman analysis shows that our system has good consistency with the reference sensor.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Intensity-modulated diode laser radar using frequency-modulation/continuous-wave ranging techniques
    Stann, BL
    Ruff, WC
    Sztankay, ZG
    OPTICAL ENGINEERING, 1996, 35 (11) : 3270 - 3278
  • [42] Event Recognition for Contactless Activity Monitoring Using Phase-Modulated Continuous Wave Radar
    Forouzanfar, Mohamad
    Mabrouk, Mohamed
    Rajan, Sreeraman
    Bolic, Miodrag
    Dajani, Hilmi R.
    Groza, Voicu Z.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (02) : 479 - 491
  • [43] Distortion Analysis of Continuous-Wave Radar Sensor for Complete Respiration Pattern Monitoring
    Gu, Changzhan
    Li, Changzhi
    2013 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2013, : 7 - 9
  • [44] Single-Channel Bioimpedance Measurement for Wearable Continuous Blood Pressure Monitoring
    Wang, Ting-Wei
    Chen, Wen-Xiang
    Chu, Hsiao-Wei
    Lin, Shien-Fong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [45] Precise Distance and Velocity Measurement for Real Time Locating in Multipath Environments Using a Frequency-Modulated Continuous-Wave Secondary Radar Approach
    Roehr, Sven
    Gulden, Peter
    Vossiek, Martin
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (10) : 2329 - 2339
  • [46] Array Radio Imaging Based on Heterodyne Detection with Application of the Continuous-Wave Radar Technique
    Korolyov, S. A.
    Goryunov, A. V.
    Parshin, V. V.
    TECHNICAL PHYSICS LETTERS, 2024, 50 (02) : 194 - 197
  • [47] Non-Contact Respiratory Triggering for Clinical MRI using Frequency Modulated Continuous Wave Radar
    Wang, Han
    Li, Yiran
    Xia, Xinyuan
    Hu, Lingzhi
    Zhao, Jun
    Chen, Qun
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [48] High-Accuracy Real-Time Monitoring of Heart Rate Variability Using 24 GHz Continuous-Wave Doppler Radar
    Petrovic, Vladimir L.
    Jankovic, Milica M.
    Lupsic, Anita, V
    Mihajlovic, Veljko R.
    Popovic-Bozovic, Jelena S.
    IEEE ACCESS, 2019, 7 : 74721 - 74733
  • [49] An On-Board Differential Patch Array for 79 GHz Single-Channel Radar Applications
    Ahmad, Wael A.
    Kissinger, Dietmar
    Ng, Herman Jalli
    2018 48TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2018, : 1385 - 1388
  • [50] An On-Board Differential Patch Array for 79 GHz Single-Channel Radar Applications
    Ahmad, Wael A.
    Kissinger, Dietmar
    Ng, Herman Jalli
    2018 15TH EUROPEAN RADAR CONFERENCE (EURAD), 2018, : 365 - 368