Electrochemical determination of imatinib mesylate using TbFeO3/g-C3N4 nanocomposite modified glassy carbon electrode

被引:14
|
作者
Baladi, Mahin [1 ]
Teymourinia, Hakimeh [2 ,3 ]
Dawi, Elmuez A. [4 ]
Amiri, Mahnaz [5 ,6 ]
Ramazani, Ali [2 ,3 ]
Salavati-Niasari, Masoud [1 ]
机构
[1] Univ Kashan, Inst Nano Sci & Nano Technol, POB 87317-51167, Kashan, Iran
[2] Univ Zanjan, Res Inst Modern Biol Tech RIMBT, Dept Biotechnol, POB 45371-38791, Zanjan, Iran
[3] Univ Zanjan, Fac Sci, Dept Chem, POB 45371-38791, Zanjan, Iran
[4] Ajman Univ, Coll Humanities & Sci, Nonlinear Dynam Res Ctr NDRC, POB 346, Ajman, U Arab Emirates
[5] Kerman Univ Med Sci, Inst Neuropharmacol, Neurosci Res Ctr, Kerman, Iran
[6] Kerman Univ Med Sci, Fac Allied Med Sci, Dept Hematol & Lab Sci, Kerman, Iran
关键词
Electrochemical Sensor; Nanostructures; CHRONIC MYELOID-LEUKEMIA; PHOTOCATALYTIC HYDROGEN EVOLUTION; CAPILLARY-ELECTROPHORESIS METHOD; CHRONIC MYELOGENOUS LEUKEMIA; MAIN METABOLITE; SQUARE-WAVE; NANOPARTICLES; AMLODIPINE; ERLOTINIB; CATALYSTS;
D O I
10.1016/j.arabjc.2023.104963
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new electrochemical sensor based on a glassy carbon electrode (GCE) modified by Tb (Terbium) FeO3/g-C3N4 (graphitic carbon nitride) nanocomposite has been developed. In order to characterize the nanocomposite produced, several techniques were employed, including X-ray diffraction (XRD), Fourier transform infrared, Field Emission Scanning Electron Microscope, Energy Dispersive X-ray Spectroscopy, Brunauer-Emmett-Teller, vibrating sample magnetometry, and Transmission Electron Microscopy (TEM). According to XRD data, the nanocomposite produced contained particles of about 36 +/- 2 nm in size. TEM examination of the voltammetric response of the offered sensor (TbFeO3/g-C3N4 nanocomposite/glassy carbon electrode (GCE)) demonstrated a catalytic effect against imatinib. In optimized solution pH and scan rate conditions, this sensor demonstrated an excellent electrocatalytic response for detecting imatinib. Furthermore, the fabricated sensor demonstrated acceptable accuracy, reproducible behavior, and a high level of stability during all electrochemical tests. In addition, analytical parameters were determined and the results were compared with those from previous studies. (c) 2023 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A prompt electrochemical monitoring platform for sensitive and selective determination of thiamethoxam using Fe2O3@g-C3N4@MSB composite modified glassy carbon electrode
    Kapoor, Atul
    Rajput, Jaspreet Kaur
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2023, 115
  • [22] Preparation and characterization of BiOBr/g-C3N4 and BiOCl/g-C3N4 electrode materials for high-performance asymmetric (BiOBr/g-C3N4|| g-C3N4) and symmetric (BiOBr/g-C3N4||BiOBr/g-C3N4) supercapattery devices
    Ramasamy, Bhuvaneshwari
    Paul, Jeya M. Peter
    Raman, Kannan
    Sundaram, Rajashabala
    JOURNAL OF ENERGY STORAGE, 2024, 102
  • [23] Graphitic carbon nitride (g-C3N4)-based electrochemical sensors for the determination of antiviral
    Sreenivasulu, Madasu
    Malode, Shweta J.
    Alqarni, Sondos Abdullah
    Shetti, Nagaraj P.
    MATERIALS CHEMISTRY AND PHYSICS, 2024, 312
  • [24] Graphitic Carbon Nitride (g-C3N4) Modified Carbon Electrodes for Electrochemical Energy Storage Systems
    Bajpai, Om Prakash
    El Koura, Zakaria
    Pucher, Ilaria
    Orlandi, Michele
    Miotello, Antonio
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (11)
  • [25] Fabrication of g-C3N4 Quantum Dots/MnCO3 Nanocomposite on Carbon Cloth for Flexible Supercapacitor Electrode
    Liu, Di
    Hur, Seung Hyun
    Chung, Jin Suk
    Choi, Won Mook
    APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 10
  • [26] Co3O4/g-C3N4 nanocomposite for enriched electrochemical water splitting
    Mohana, P.
    Swathi, S.
    Yuvakkumar, R.
    Ravi, G.
    Thambidurai, M.
    Nguyen, Hung D.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 49 : 376 - 389
  • [27] Electrochemical Determination of Paraquat Using Ordered Mesoporous Carbon (CMK-3) Modified Glassy Carbon Electrode
    Rajaram, Rajendran
    Kumar, Sachin
    Ramanujam, Kothandaraman
    Neelakantan, Lakshman
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (08)
  • [28] Simple and Highly Sensitive Electrochemical Sensor for Sunset Yellow Detection Based on Co3O4/g-C3N4 Nanocomposite Modified Gold Electrode
    Sundaresan, Sumi
    Sowmya, Subramanian
    Vijaikanth, Vijendran
    CHEMISTRYSELECT, 2024, 9 (40):
  • [29] Electrochemical determination of benzoic acid using CuGeO3 nanowire modified glassy carbon electrode
    Cai, Z. Y.
    Pei, L. Z.
    Xie, Y. K.
    Fan, C. G.
    Fu, D. G.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (09)
  • [30] Electrochemical Determination of Pentachlorophenol Using a Glassy Carbon Electrode Modified with a Film of CuS Nanocomposite-Chitosan
    Zou, Jing
    Ma, Jinai
    Zhang, Yuanxiao
    Li, Lu
    Jiang, Jizhou
    Chen, Jinfang
    ANALYTICAL LETTERS, 2013, 46 (07) : 1108 - 1116