Reduction in Thrombolytic Usage in Hemodialysis Patients Following a Quality Assurance Review: A Research Letter

被引:0
|
作者
Bau, Jason T. [1 ,5 ]
Younis, Kokab [2 ,3 ]
Gallagher, Nathen [2 ]
Harrison, Tyrone G. [1 ,2 ,4 ]
Leung, Kelvin [1 ,2 ]
Hemmett, Juliya [1 ,2 ]
Qirjazi, Elena [1 ,2 ]
机构
[1] Univ Calgary, Dept Med, Calgary, AB, Canada
[2] Alberta Hlth Serv, Calgary, AB, Canada
[3] Univ Calgary, Fac Nursing, Calgary, AB, Canada
[4] Univ Calgary, OBrien Inst Publ Hlth, Cumming Sch Med, Calgary, AB, Canada
[5] Univ Calgary, Med Sch, Dept Med, 2500 Univ Drive NW,3330 Hosp Dr NW, Calgary, AB T2N 4N1, Canada
关键词
vascular access; catheter-related thrombus; hemodialysis catheter; quality improvement; Alberta;
D O I
10.1177/20543581231174276
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background:Catheter malfunction in hemodialysis (HD) is increasingly managed with recombinant tissue plasminogen activator (rt-PA, alteplase), though evidence of improved catheter function is lacking. Objective:To evaluate the effect of a standardized rt-PA administration protocol on rt-PA usage, catheter function, and adverse events. Design:Observational quality improvement study. Setting:Single, urban, community HD unit in Calgary, Alberta. Patients:Patients treated with maintenance in-center HD through central venous catheter. Outcomes:Incidence of rt-PA usage, catheter interventions, hospitalizations, and measures of dialysis efficacy. Methods:The rt-PA protocol was designed following a consultative and iterative design period with dialysis shareholders, which included focusing on standard objective criteria before use and targeting use to the problematic lumen. Protocol implementation occurred over a 6-month period in 2021. Patient and dialysis data were collected through our regional dialysis electronic health record. Results:Implementation of the rt-PA protocol resulted in decreased rt-PA use (standardized per 100 dialysis sessions) compared to the preprotocol period (incidence rate ratio [IRR] of 0.57, 95% confidence interval [CI]: [0.34, 0.94]). Line procedures were also less frequent (IRR = 0.42, 95% CI: [0.18, 0.89]). Hospitalization rates and measures of dialysis efficacy were similar in both periods. Limitations:Small sample size with single dialysis center and short duration of follow-up. Conclusions:Implementation of a multidisciplinary designed rt-PA administration protocol decreased incident rt-PA usage
引用
收藏
页数:5
相关论文
共 50 条
  • [41] A Bibliometric Mapping of Research on Quality Assurance in African Higher Education: a systematic literature review (from 1999 to 2019)
    Joao, Luis M.
    Langa, Patricio
    18TH INTERNATIONAL CONFERENCE ON SCIENTOMETRICS & INFORMETRICS (ISSI2021), 2021, : 1489 - 1490
  • [42] A DESCRIPTIVE RESEARCH ON DEMOGRAPHIC FACTORS ASSOCIATION WITH MORTALITY, MORBIDITY AND QUALITY OF LIFE (QOL) OF HEMODIALYSIS PATIENTS
    Shahid, Shahzad
    ul Hassan, Umair
    Bhutta, Uzma Atta
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (08): : 8160 - +
  • [43] Do they listen? A review of information retained by patients following consent for reduction mammoplasty
    Godwin, Y
    BRITISH JOURNAL OF PLASTIC SURGERY, 2000, 53 (02): : 121 - 125
  • [44] A review of patients with pulmonary aspiration of gastric contents during anesthesia reported to the Departmental Quality Assurance Committee
    Neelakanta, G
    Chikyarappa, A
    JOURNAL OF CLINICAL ANESTHESIA, 2006, 18 (02) : 102 - 107
  • [45] Parotid gland tumours in 255 consecutive patients: Mount Sinai Hospital's quality assurance review
    Gooden, E
    Witterick, IJ
    Hacker, D
    Rosen, IB
    Freeman, JL
    JOURNAL OF OTOLARYNGOLOGY, 2002, 31 (06): : 351 - 354
  • [46] Effect of aromatherapy on quality of life in maintenance hemodialysis patients: a systematic review and meta-analysis
    Zhang, Cong
    Mu, Hang
    Yang, Yong-Fang
    Zhang, Yong
    Gou, Wen-Jun
    RENAL FAILURE, 2023, 45 (01)
  • [47] Quality of life and functional capacity in depressive patients on hemodialysis: a systematic review and meta-analysis
    Moreira, M. B.
    Cavalli, N. P.
    Righi, N. C.
    Schuch, F. B.
    Signori, L. U.
    da Silva, A. M. V.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2023, 56
  • [48] Effectiveness of psychosocial interventions on the burden and quality of life of informal caregivers of hemodialysis patients: a systematic review
    Bartolo, Ana
    Sousa, Helena
    Ribeiro, Oscar
    Figueiredo, Daniela
    DISABILITY AND REHABILITATION, 2022, 44 (26) : 8176 - 8187
  • [49] COMPUTERIZED MEDICAL INFORMATION-SYSTEM ENHANCES QUALITY ASSURANCE - A 10-YEAR EXPERIENCE IN CHRONIC MAINTENANCE HEMODIALYSIS-PATIENTS
    POLLAK, VE
    NEPHRON, 1990, 54 (02) : 109 - 116
  • [50] Unlocking patients' records in general practice for research, medical education and quality assurance: The Registration Network Family Practices
    Department of General Practice, University of Limburg, PO Box 616, 6200 MD Maastricht, Netherlands
    INT. J. BIO-MED. COMPUT., 1-2 (43-50):