Rectifying unexpected injection issues due to an elliptically polarizing undulator

被引:0
|
作者
Wurtz, W. A. [1 ]
Baribeau, C. K. [1 ]
Sigrist, M. J. [1 ]
机构
[1] Univ Saskatchewan, Canadian Light Source Inc, Saskatoon, SK S7N 2V3, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Storage ring; Injection; Insertion device; Dynamic aperture; Field integral; T WIGGLER;
D O I
10.1016/j.nima.2022.168001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Top-up operation requires high efficiency injection with insertion devices at small gaps. We present a case study of one elliptically polarizing undulator at the Canadian Light Source that unexpectedly began having a detrimental impact on injection efficiency after operating for many years without issue. By performing beam -based measurements in the storage ring and magnetic measurements in our magnetic measurement laboratory, we built a model that provided an explanation and a remedy. An unrelated change in the vertical limiting physical aperture coupled to an octupole resonance caused a loss of dynamic aperture that explained the decreased injection efficiency. The remedy was to change the on-axis tunes of the storage ring, avoiding the resonance. We hope this detailed and thorough case study may help other laboratories to maintain high injection efficiency while requiring a minimum of restrictions on insertion device operating ranges.
引用
收藏
页数:10
相关论文
共 25 条
  • [21] An SRRC elliptically polarizing undulator prototype to examine mechanical design feasibility and magnetic field performance
    Chang, CH
    Hwang, CS
    Fan, TC
    Chen, KH
    Pan, KT
    Lin, FY
    Wang, C
    Chang, LH
    Chen, HH
    Lin, MC
    Yeh, ST
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 420 - 422
  • [22] Magnetic high-resolution spectroscopy with Beamline 4.0.1-2: An elliptically polarizing undulator beamline at the Advanced Light Source
    Young, AT
    Martynov, V
    Padmore, HA
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 : 885 - 889
  • [23] Magnetic high-resolution spectroscopy with Beamline 4.0.1-2: An elliptically polarizing undulator beamline at the Advanced Light Source
    Young, Anthony T.
    Martynov, Vladimir
    Padmore, Howard A.
    Journal of Electron Spectroscopy and Related Phenomena, 1999, 101 : 885 - 889
  • [24] Hyperbaric Oxygen for Ischemia due to Injection of Cosmetic Fillers: Case Report and Issues
    Henderson, Raven
    Reilly, Debra A.
    Cooper, Jeffrey S.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2018, 6 (01)
  • [25] On Addressing the Security and Stability Issues Due to False Data Injection Attacks in DC Microgrids-An Adaptive Observer Approach
    Cecilia, Andreu
    Sahoo, Subham
    Dragicevic, Tomislav
    Costa-Castello, Ramon
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (03) : 2801 - 2814