Redo procedures after sinus node sparing hybrid ablation for inappropriate sinus tachycardia/postural orthostatic sinus tachycardia

被引:0
|
作者
de Asmundis, Carlo [1 ]
Marcon, Lorenzo [1 ]
Pannone, Luigi [1 ]
Della Rocca, Domenico Giovanni [1 ]
Lakkireddy, Dhanunjaya [2 ]
Beaver, Thomas M. [3 ]
Brodt, Chad R. [1 ,4 ]
Monaco, Cinzia [1 ]
Sorgente, Antonio [1 ]
Audiat, Charles [1 ]
Vetta, Giampaolo [1 ]
Ramak, Robbert [1 ]
Overeinder, Ingrid [1 ]
Kronenberger, Rani [5 ]
Bala, Gezim [1 ]
Almorad, Alexandre [1 ]
Stroker, Erwin [1 ]
Sieira, Juan [1 ]
Sarkozy, Andrea [1 ]
Brugada, Pedro [1 ]
Chierchia, Gian Battista [1 ]
La Meir, Mark [5 ]
机构
[1] Vrije Univ Brussel, Heart Rhythm Management Ctr, Postgrad Program Cardiac Electrophysiol & Pacing, European Reference Networks Guard Heart,Univ Zieke, Laarbeeklaan 101, B-1090 Brussels, Belgium
[2] Kansas City Heart Rhythm Inst, Overland Pk, KS USA
[3] Univ Florida, Dept Surg, Div Thorac & Cardiovasc Surg, Gainesville, FL USA
[4] Sequoia Hosp, Palo Alto, CA USA
[5] Vrije Univ Brussel, Univ Ziekenhuis Brussel, Cardiac Surg Dept, Brussels, Belgium
来源
EUROPACE | 2023年 / 26卷 / 01期
关键词
Sinus node; inappropriate sinus node tachycardia; postural orthostatic sinus tachycardia; hybrid ablation; redo ablation; PREVALENCE;
D O I
10.1093/europace/euad373
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. Methods and results All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS. After a follow-up of 73.3 +/- 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. Conclusion In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Radiofrequency catheter modification of sinus node activity in patients with inappropriate sinus tachycardia
    Scheinman, MM
    Shinbane, JS
    Lesh, MD
    Lee, RJ
    CARDIAC ARRHYTHMIAS, PACING & ELECTROPHYSIOLOGY: THE EXPERT VIEW, 1998, 201 : 215 - 222
  • [42] Heart rate variability and inappropriate sinus tachycardia after catheter ablation of supraventricular tachycardia
    Madrid, AH
    Mestre, JL
    Moro, C
    Vivas, E
    Tejero, I
    Novo, L
    Marin, E
    Orellana, L
    EUROPEAN HEART JOURNAL, 1995, 16 (11) : 1637 - 1640
  • [43] Hybrid epicardial and endocardial sinus node-sparing ablation therapy for inappropriate sinus tachycardia: Rationale and design of the multicenter HEAL-IST IDE trial
    de Asmundis, Carlo
    Pannone, Luigi
    Lakkireddy, Dhanunjaya
    Beaver, Thomas M.
    Brodt, Chad R.
    Lee, Randall J.
    Frazier, Kenneth
    Chierchia, Gian-Battista
    La Meir, Mark
    HEART RHYTHM O2, 2023, 4 (04): : 275 - 282
  • [44] Inappropriate sinus tachycardia in a dog
    Oliveira, Pedro
    Arnott, Holly
    Mavropoulou, Antonia
    VETERINARY RECORD CASE REPORTS, 2018, 6 (02):
  • [45] MECHANISM OF INAPPROPRIATE SINUS TACHYCARDIA
    MORILLO, CA
    THAKUR, RK
    LI, HG
    ZARDINI, M
    YEE, R
    KLEIN, GJ
    CIRCULATION, 1993, 88 (04) : 45 - 45
  • [46] Inappropriate sinus tachycardia: a review
    Ali, Muzaffar
    Haji, Abdul Qadir
    Kichloo, Asim
    Grubb, Blair P.
    Kanjwal, Khalil
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2021, 22 (04) : 1331 - 1339
  • [47] Treatment for Inappropriate Sinus Tachycardia
    Salazar Adum, Juan Pablo
    Arora, Rohit
    AMERICAN JOURNAL OF THERAPEUTICS, 2017, 24 (05) : E574 - E578
  • [48] Is inappropriate sinus tachycardia really inappropriate?
    Morillo, CA
    León, H
    Pava, F
    CARDIAC ARRHYTHMIAS 2001, 2002, : 320 - 323
  • [49] Ablation of inappropriate sinus tachycardia: Is it time to review choices?
    Pachon-M, Jose Carlos
    Pachon-M, Enrique I.
    HEART RHYTHM, 2022, 19 (01) : 39 - 40
  • [50] INAPPROPRIATE SINUS TACHYCARDIA AND POSTURAL TACHYCARDIA SYNDROME: DISTINCT ENTITIES OR OVERLAPPING DISEASES
    Shabtaie, Samuel
    Witt, Chance
    Asirvatham, Samuel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 235 - 235