Factors that influence the accuracy of maxillomandibular relationship at maximum intercuspation acquired by using intraoral scanners: A systematic review

被引:9
|
作者
Revilla-Leon, Marta [1 ,2 ,3 ,9 ]
Barmak, Abdul B. [4 ]
Tohme, Hani [5 ]
Yilmaz, Burak [6 ,7 ,8 ]
Kois, John C. [9 ,10 ]
Gomez-Polo, Miguel [11 ]
机构
[1] Univ Washington, Dept Restorat Dent, Sch Dent, Seattle, WA USA
[2] Kois Ctr, Fac & Director Res & Digital Dent, Seattle, WA USA
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA USA
[4] Univ Rochester, Med Ctr, Eastman Inst Oral Hlth, Rochester, NY USA
[5] St Joseph Univ Beirut, Fac Dent Med, Digital AI & Evolving Technol, Beirut, Lebanon
[6] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[7] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[8] Ohio State Univ, Div Restorat & Prosthet Dent, Columbus, OH USA
[9] Kois Ctr, 1001 Fairview Ave N 2200, Seattle, WA 98109 USA
[10] Univ Washington, Dept Restorat Dent, Grad Prosthodont, Seattle, WA USA
[11] Univ Complutense Madrid, Sch Dent, Madrid, Spain
关键词
Accuracy; Digital occlusion; Digital scans; Influencing factors; Intraoral scanners; Maxillomandibular relationship; Static occlusion; REPRODUCIBILITY; REGISTRATION; CONTACTS; RECORDS;
D O I
10.1016/j.jdent.2023.104718
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To review the factors that influence the accuracy of the maxillomandibular relationship at maximum intercuspation (MIP) acquired by using intraoral scanners (IOSs).Material and methods: A systematic search was performed using five databases: MEDLINE/PubMed, Cochrane, Embase, World of Science, and Scopus. A manual search was also completed. Studies assessing the factors that influence the MIP acquired by using IOSs were included and organized based on the analyzed factor. Studies were evaluated by applying the Joanna Briggs Institute Critical Appraisal Checklist.Results: Twenty-nine articles were included. Seven factors have been identified: IOS system, scan extension, edentulous areas, number, location, and extension of occlusal records, occlusal force, tooth mobility, and alignment methods. Nine studies evaluated the influence of IOS system. Four studies assessed the influence of the extension of the arch scan. Three studies evaluated the effect of edentulous spaces. Four studies agreed on the impact of the number, location, and extension of the occlusal records on the MIP accuracy. One study assessed the influence of the occlusal force, showing a smaller average interocclusal space with increased occlusal force. One study evaluated the influence of tooth mobility. Seven studies analyzed the influence of the alignment method on the MIP accuracy.Conclusions: Most of the studies reported no difference on the MIP accuracy between half-and complete-arch scans. Areas with 2 or more missing teeth reduce the MIP accuracy. A bilateral and frontal record including 2 teeth or a bilateral posterior occlusal including at least 4-teeth is indicated for maximizing the MIP accuracy. Clinical implications: When a complete-arch intraoral scans is obtained, a bilateral and frontal record including 2 teeth or a bilateral posterior occlusal record including at least 4-teeth is recommended for maximizing the ac-curacy of the MIP. When a half-arch intraoral scan is acquired, a posterior occlusal record including at least 4-teeth is indicated for optimizing the accuracy of the MIP.
引用
收藏
页数:8
相关论文
共 45 条
  • [21] Evaluation of the accuracy of intraoral scanners for complete-arch scanning: A systematic review and network meta-analysis
    Vitai, Viktoria
    Nemeth, Anna
    Solyom, Eleonora
    Czumbel, Laszlo Mark
    Szabo, Bence
    Fazekas, Reka
    Gerber, Gabor
    Hegyi, Peter
    Hermann, Peter
    Borbely, Judit
    JOURNAL OF DENTISTRY, 2023, 137
  • [22] Evaluation Methods and Influencing Factors on Accuracy for Static Virtual Articulation Obtained by Intraoral Scanners: A Critical Review of the Literature
    Zheng, Yuying
    Zhang, Tingmin
    Liu, Yuchen
    Pradies, Guillermo
    Wang, Xin
    Ma, Dan
    Bai, Shizhu
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [23] Differences in maxillomandibular relationship recorded at centric relation when using a conventional method, four intraoral scanners, and a jaw tracking system: A clinical study
    Revilla-Leon, Marta
    Agustin-Panadero, Ruben
    Zeitler, Jonathan M.
    Barmak, Abdul B.
    Yilmaz, Burak
    Kois, John C.
    Perez-Barquero, Jorge Alonso
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 964 - 972
  • [24] Influence of the ambient color lighting on the accuracy of complete arch implant scans recorded by using two intraoral scanners
    Ochoa-Lopez, Gaston
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02): : 552 - 559
  • [25] Influence of implant position on the accuracy of intraoral scanning in fully edentulous arches: A systematic review
    Pereira, Ana Larisse Carneiro
    Carreiro, Adriana da Fonte Porto
    Medeiros, Vitoria Ramos
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (06): : 749 - 755
  • [26] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [27] A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies
    Gehrke, Peter
    Rashidpour, Mahsa
    Sader, Robert
    Weigl, Paul
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [28] Living with dementia: A systematic review of the influence of relationship factors
    Ablitt, Astri
    Jones, Gregory V.
    Muers, Jane
    AGING & MENTAL HEALTH, 2009, 13 (04) : 497 - 511
  • [29] Linear Accuracy of Intraoral Scanners for Full-Arch Impressions of Implant-Supported Prostheses: A Systematic Review and Meta-Analysis
    Floriani, Franciele
    Lopes, Guilherme Carpena
    Cabrera, Alexandre
    Duarte, Wagner
    Zoidis, Panagiotis
    Oliveira, Dayane
    Rocha, Mateus Garcia
    EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 964 - 973
  • [30] EPA Consensus Project Paper: Accuracy of Photogrammetry Devices, Intraoral Scanners, and Conventional Techniques for the Full-Arch Implant Impressions: A Systematic Review
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Mischitz, Ingrida
    Mijiritsky, Eitan
    Huber, Sandra
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2023,