Pelvic PET/MR attenuation correction in the image space using deep learning

被引:2
|
作者
Abrahamsen, Bendik Skarre [1 ]
Knudtsen, Ingerid Skjei [1 ]
Eikenes, Live [1 ]
Bathen, Tone Frost [1 ,2 ]
Elschot, Mattijs [1 ,2 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, Trondheim, Norway
[2] Trondheim Reg & Univ Hosp, St Olavs Hosp, Dept Radiol & Nucl Med, Trondheim, Norway
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
基金
芬兰科学院;
关键词
PET/MR; attenuation correction; deep learning; prostate cancer; artificial intelligence frontiers; MRAC; pseudo-CT; PROSTATE-CANCER; ECHO-TIME; CT IMAGES; MR;
D O I
10.3389/fonc.2023.1220009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
IntroductionThe five-class Dixon-based PET/MR attenuation correction (AC) model, which adds bone information to the four-class model by registering major bones from a bone atlas, has been shown to be error-prone. In this study, we introduce a novel method of accounting for bone in pelvic PET/MR AC by directly predicting the errors in the PET image space caused by the lack of bone in four-class Dixon-based attenuation correction.MethodsA convolutional neural network was trained to predict the four-class AC error map relative to CT-based attenuation correction. Dixon MR images and the four-class attenuation correction & mu;-map were used as input to the models. CT and PET/MR examinations for 22 patients ([18F]FDG) were used for training and validation, and 17 patients were used for testing (6 [18F]PSMA-1007 and 11 [68Ga]Ga-PSMA-11). A quantitative analysis of PSMA uptake using voxel- and lesion-based error metrics was used to assess performance.ResultsIn the voxel-based analysis, the proposed model reduced the median root mean squared percentage error from 12.1% and 8.6% for the four- and five-class Dixon-based AC methods, respectively, to 6.2%. The median absolute percentage error in the maximum standardized uptake value (SUVmax) in bone lesions improved from 20.0% and 7.0% for four- and five-class Dixon-based AC methods to 3.8%.ConclusionThe proposed method reduces the voxel-based error and SUVmax errors in bone lesions when compared to the four- and five-class Dixon-based AC models.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Brain PET-MR attenuation correction with deep learning
    Yaakub, S. N.
    McGinnity, C. J.
    Beck, K.
    Merida, I.
    Dunston, E.
    Muffoletto, M.
    Qureshi, A.
    Bhattacharya, S.
    MacKewn, J.
    Hammers, A.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 600 - 601
  • [2] Attenuation correction and truncation completion for breast PET/MR imaging using deep learning
    Li, Xue
    Johnson, Jacob M.
    Strigel, Roberta M.
    Bancroft, Leah C. Henze
    Hurley, Samuel A.
    Estakhraji, S. Iman Zare
    Kumar, Manoj
    Fowler, Amy M.
    McMillan, Alan B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04):
  • [3] Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging
    Liu, Fang
    Jang, Hyungseok
    Kijowski, Richard
    Bradshaw, Tyler
    McMillan, Alan B.
    RADIOLOGY, 2018, 286 (02) : 676 - 684
  • [4] Deep Learning based Segmentation for Multi MR Imaging Protocols using Transfer Learning for PET Attenuation Correction
    Mecheter, Imene
    Amira, Abbes
    Abbod, Maysam
    Zaidi, Habib
    2020 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (SSCI), 2020, : 2516 - 2520
  • [5] Feasibility of Deep Learning-Based PET/MR Attenuation Correction in the Pelvis Using Only Diagnostic MR Images
    Bradshaw, Tyler J.
    Zhao, Gengyan
    Jang, Hyungseok
    Liu, Fang
    McMillan, Alan B.
    TOMOGRAPHY, 2018, 4 (03) : 138 - 147
  • [6] Improved MR to CT Synthesis for PET/MR Attenuation Correction Using Imitation Learning
    Klaser, Kerstin
    Varsavsky, Thomas
    Markiewicz, Pawel
    Vercauteren, Tom
    Atkinson, David
    Thielemans, Kris
    Hutton, Brian
    Cardoso, M. Jorge
    Ourselin, Sebastien
    SIMULATION AND SYNTHESIS IN MEDICAL IMAGING, SASHIMI 2019, 2019, 11827 : 13 - 21
  • [7] Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences
    Park, Chan Rok
    Lee, Youngjin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (06) : 1610 - 1615
  • [8] Evaluation of attenuation correction in cardiac PET using PET/MR
    Lau, Jeffrey M. C.
    Laforest, R.
    Sotoudeh, H.
    Nie, X.
    Sharma, S.
    McConathy, J.
    Novak, E.
    Priatna, A.
    Gropler, R. J.
    Woodard, P. K.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 839 - 846
  • [9] Evaluation of attenuation correction in cardiac PET using PET/MR
    Jeffrey M. C. Lau
    R. Laforest
    H. Sotoudeh
    X. Nie
    S. Sharma
    J. McConathy
    E. Novak
    A. Priatna
    R. J. Gropler
    P. K. Woodard
    Journal of Nuclear Cardiology, 2017, 24 : 839 - 846
  • [10] Attenuation Correction of PET/MR Using Deep Neural Network Based on Dixon and ZTE MR Images
    Gong, Kuang
    Yang, Jaewon
    Kim, Kyungsang
    El Fakhri, Georges
    Seo, Youngho
    Li, Quanzheng
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59