Seismic performance of precast concrete walls with grouted sleeve connections using large-diameter bars

被引:11
|
作者
Cheng, Junfeng [1 ]
Luo, Xiaoyong [1 ,2 ]
Cheng, Qian [1 ]
Xing, Minliang [1 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha 410075, Hunan, Peoples R China
[2] Prefabricated Construct Engn & Technol Res Ctr Hun, Changsha 410075, Peoples R China
关键词
Precast concrete (PC) walls; Keyway-type horizontal joint; Large-diameter bars; Connection strength; Seismic performance; SHEAR WALLS; REINFORCING BARS; BEHAVIOR; SPLICE; BOND;
D O I
10.1016/j.soildyn.2023.107905
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper proposes an innovative assembly technique using large-diameter bars anchored in several single-row, widely spaced grouted sleeves at the keyway-type horizontal joint to realize an indirect vertical connection between adjacent precast concrete (PC) walls, which has the advantages of high efficiency and ease of con-struction. To examine the effect of vertical connection strength (rebars' diameter at horizontal joints) on the seismic performance of PC shear walls, quasi-static cyclic loading tests on five full-size wall specimens, including one cast-in-place specimen and four PC specimens with grouted sleeve connections, are carried out. Seismic performance indicators in terms of failure modes, hysteresis characteristics, energy dissipation, ductility, and stiffness degradation of PC walls are investigated and compared with those of the cast-in-situ wall. Meanwhile, the method for predicting the bearing capacity of PC walls with large-diameter rebars is developed. The results show that the failure modes of cast-in-situ and precast walls are controlled by bending instead of shear, but there is an obvious difference in the crack propagation between the two types of walls. Carrying capacity, ductility factor, stiffness, and energy dissipation of PC walls are significantly enhanced by increasing the connection strength, by 44.1%, 23.9%, 72.1%, and 24.0%, respectively, when the connection strength reaches around 90%. Particularly, the PC wall's seismic performance is comparable to that of the cast-in-situ wall when the connection strength is 90%. The calculated results are well-matched with the experimental results, the proposed calculation method reliably predicts the bearing capacity of PC walls with large-diameter rebars. The assembly technique can be safely applied to multi-story PC wall panel structures in seismic zones.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Study of effects of sleeve grouting defects on the seismic performance of precast concrete shear walls
    Xiao, Shun
    Wang, Zhuolin
    Li, Xiangmin
    Harries, Kent A.
    Xu, Qingfeng
    Gao, Rundong
    ENGINEERING STRUCTURES, 2021, 236
  • [32] Experimental study on seismic behavior of precast concrete column with grouted sleeve connections considering ratios of longitudinal reinforcement and stirrups
    Yangqing Liu
    Binbin Zhou
    Jianguo Cai
    Daniel Sang-Hoon Lee
    Xiaowei Deng
    Jian Feng
    Bulletin of Earthquake Engineering, 2018, 16 : 6077 - 6104
  • [33] Experimental study on seismic behavior of precast concrete column with grouted sleeve connections considering ratios of longitudinal reinforcement and stirrups
    Liu, Yangqing
    Zhou, Binbin
    Cai, Jianguo
    Lee, Daniel Sang-Hoon
    Deng, Xiaowei
    Feng, Jian
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (12) : 6077 - 6104
  • [34] Impact resistance performance of precast reinforced concrete barriers with grouted sleeve and steel angle-to-plate connections
    Zhao, Hui
    Xie, Zongwang
    Yang, Bohui
    Li, Lijun
    Wang, Rui
    Chen, Wensu
    ENGINEERING STRUCTURES, 2024, 316
  • [35] Shear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading
    Feng, Bo
    Xiong, Feng
    Liu, Bingyu
    Chen, Jiang
    Zhang, Yiping
    PLOS ONE, 2016, 11 (11):
  • [36] Seismic performance of precast concrete shear walls based on grouted corrugated metallic duct hybrid connection
    Bi, Yu
    Yao, ZiQi
    Qin, YongJun
    Kali, Abudusaimaiti
    Chen, Qi
    Niyazi, Hushitaer
    Construction and Building Materials, 2024, 450
  • [37] Cyclic performance of precast concrete shear walls with a mortar-sleeve connection for longitudinal steel bars
    Peng, Yuan-Yuan
    Qian, Jia-Ru
    Wang, Yu-Hang
    MATERIALS AND STRUCTURES, 2016, 49 (06) : 2455 - 2469
  • [38] Experimental study on seismic behavior of precast concrete circular section column with grouted sleeve
    Zeng, Zhixing
    Yu, Wenmao
    Luo, Yi
    Wu, Chen
    Liu, Xiang
    JOURNAL OF BUILDING ENGINEERING, 2022, 46
  • [39] Seismic Analysis of Precast Concrete Bridge Columns Connected with Grouted Splice Sleeve Connectors
    Ameli, M. J.
    Pantelides, Chris P.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (02)
  • [40] Experimental study on seismic performance of precast concrete shear walls with treatment of sleeve grouting defects
    Xiao S.
    Li X.
    Xu Q.
    Jiang H.
    Gao R.
    Wang Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (04): : 167 - 176