Quantitative evaluation of the reduction of distortion and metallic artifacts in magnetic resonance images using the multiacquisition variable-resonance image combination selective sequence

被引:1
|
作者
Hirano, Masaki [1 ,2 ]
Muto, Yuki [1 ,3 ]
Kuroda, Masahiro [1 ]
Fujiwara, Yuta [4 ]
Sasaki, Tomoaki [1 ,5 ]
Kuroda, Kazuhiro [1 ,6 ]
Kamizaki, Ryo [1 ]
Imajoh, Satoshi [1 ]
Tanabe, Yoshinori [1 ]
Al-Hammad, Wlla E. [7 ]
Nakamitsu, Yuki [1 ]
Shimizu, Yudai [7 ]
Sugimoto, Kohei [8 ]
Oita, Masataka [8 ]
Sugianto, Irfan [9 ]
Bamgbose, Babatunde O. [10 ]
机构
[1] Okayama Univ, Grad Sch Hlth Sci, Dept Radiol Technol, 2-5-1 Shikata Cho,Kita Ku, Okayama 7008558, Japan
[2] Osaka Red Cross Hosp, Dept Radiol, Osaka 5438555, Japan
[3] Oomoto Hosp, Dept Radiol, Okayama 7000924, Japan
[4] Okayama Cent Hosp, Div Clin Radiol Serv, Okayama 7000017, Japan
[5] Natl Canc Ctr Hosp East, Dept Diagnost Radiol, Chiba 2778577, Japan
[6] Okayama Prefectural Univ, Grad Sch Hlth & Welf Sci, Dept Hlth & Welf Sci, Okayama 7191197, Japan
[7] Okayama Univ, Dept Oral & Maxillofacial Radiol, Grad Sch Med Dent & Pharmaceut Sci, Okayama 7000017, Japan
[8] Okayama Univ, Grad Sch Interdisciplinary & Sci & Engn Hlth Syst, Okayama 7708558, Japan
[9] Hasanuddin Univ, Fac Dent, Dept Oral Radiol, Makassar 90245, Sulawesi, Indonesia
[10] Bayero Univ, Fac Dent, Dept Oral Diagnost Sci, Kano, Nigeria
关键词
MAVRIC SL; metal artifacts; implant; phantom; MRI; SPIN-ECHO SEQUENCES; MAVRIC-SL; 3-T MRI; IMPLANTS;
D O I
10.3892/etm.2023.11808
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Magnetic resonance imaging (MRI) is superior to computed tomography (CT) in determining changes in tissue structure, such as those observed following inflammation and infection. However, when metal implants or other metal objects are present, MRI exhibits more distortion and artifacts compared with CT, which hinders the accurate measurement of the implants. A limited number of reports have examined whether the novel MRI sequence, multiacquisition variable-resonance image combination selective (MAVRIC SL), can accurately measure metal implants without distortion. Therefore, the present study aimed to demonstrate whether MAVRIC SL could accurately measure metal implants without distortion and whether the area around the metal implants could be well delineated without artifacts. An agar phantom containing a titanium alloy lumbar implant was used for the present study and was imaged using a 3.0 T MRI machine. A total of three imaging sequences, namely MAVRIC SL, CUBE and magnetic image compilation (MAGiC), were applied and the results were compared. Distortion was evaluated by measuring the screw diameter and distance between the screws multiple times in the phase and frequency directions by two different investigators. The artifact region around the implant was examined using a quantitative method following standardization of the phantom signal values. It was revealed that MAVRIC SL was a superior sequence compared with CUBE and MAGiC, as there was significantly less distortion, a lack of bias between the two different investigators and significantly reduced artifact regions. These results suggested the possibility of utilizing MAVRIC SL for follow-up to observe metal implant insertions.
引用
收藏
页数:9
相关论文
共 30 条
  • [21] REGIONAL VARIATIONS IN TRABECULAR STRUCTURE IN THE CALCANEUS ASSESSED USING HIGH-RESOLUTION MAGNETIC-RESONANCE IMAGES AND QUANTITATIVE IMAGE-ANALYSIS
    MAJUMDAR, S
    GENANT, HK
    GIES, AA
    GUGLIELMI, G
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S351 - S351
  • [22] Scan time reduction in 23Na-Magnetic Resonance Imaging using the chemical shift imaging sequence: Evaluation of an iterative reconstruction method
    Weingaertner, Sebastian
    Wetterling, Friedrich
    Konstandin, Simon
    Fatar, Marc
    Neumaier-Probst, Eva
    Schad, Lothar R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (03): : 275 - 286
  • [23] Longitudinal quantitative evaluation of lesion size change in femoral head osteonecrosis using three-dimensional magnetic resonance imaging and image registration
    Takao, Masaki
    Sugano, Nobuhiko
    Nishii, Takashi
    Miki, Hidenobu
    Sato, Yoshinobu
    Tamura, Shinichi
    Yoshikawa, Hideki
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (06) : 1231 - 1239
  • [24] Quantitative evaluation of the image quality using the fast nonlocal means denoising approach in diffusion-weighted magnetic resonance imaging with high b-value
    Park, Jaeyoung
    Kang, Chang-Ki
    Lee, Youngjin
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 78 (03) : 244 - 250
  • [25] Quantitative evaluation of the image quality using the fast nonlocal means denoising approach in diffusion-weighted magnetic resonance imaging with high b-value
    Jaeyoung Park
    Chang-Ki Kang
    Youngjin Lee
    Journal of the Korean Physical Society, 2021, 78 : 244 - 250
  • [26] Image Diagnostic Classification of Magnetic Resonance T2 Increased Signal Intensity in Cervical Spondylotic Myelopathy Clinical Evaluation Using Quantitative and Objective Assessment
    Machino, Masaaki
    Imagama, Shiro
    Ando, Kei
    Kobayashi, Kazuyoshi
    Ito, Kenyu
    Tsushima, Mikito
    Matsumoto, Akiyuki
    Morozumi, Masayoshi
    Tanaka, Satoshi
    Ito, Keigo
    Kato, Fumihiko
    Nishida, Yoshihiro
    Ishiguro, Naoki
    SPINE, 2018, 43 (06) : 420 - 426
  • [27] Simultaneous Luminal and Hemodynamic Evaluation of the Cervical Arteries Using Nonenhanced 3D Quantitative Quiescent-Interval Slice-Selective Magnetic Resonance Angiography
    Koktzoglou, Ioannis
    Ozturk, Onural
    Ankenbrandt, William J.
    Walker, Matthew T.
    Bulwa, Zachary B.
    Gil, Fulvio R.
    Ares, William J.
    Leloudas, Nondas
    Edelman, Robert R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025,
  • [28] Quantitative evaluation of white matter hyperintensities in patients with heart failure using an innovative magnetic resonance image analysis method: Association with disrupted circadian blood pressure variation
    Komori, Takahiro
    Hoshide, Satoshi
    Tabei, Ken-ichi
    Tomimoto, Hidekazu
    Kario, Kazuomi
    JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (05): : 1089 - 1092
  • [29] Qualitative and quantitative evaluation of skeletal muscle fatty degenerative changes using whole-body Dixon nuclear magnetic resonance imaging for an important reduction of the acquisition time
    Baudin, Pierre-Yves
    Marty, Benjamin
    Robert, Benjamin
    Shukelovitch, Alexey
    Carlier, Robert Y.
    Azzabou, Noura
    Carlier, Pierre G.
    NEUROMUSCULAR DISORDERS, 2015, 25 (10) : 758 - 763
  • [30] Liver Biliary Function Evaluation on a 1.5T Magnetic Resonance Imaging Scan by T1 Reduction Rate Assessment Using Variable-Flip-Angle Sequences
    Di Stasio, Marco
    Cordopatri, Cesare
    Nardi, Cosimo
    Busoni, Simone
    Noferini, Linhsia
    Colagrande, Stefano
    Calistri, Linda
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (03) : 354 - 360