Modified pull-off test evaluation of bond properties in preplaced aggregate concrete incorporating silica fume

被引:3
|
作者
Das, Kunal Krishna [1 ,2 ]
Lam, Eddie Siu-Shu [1 ]
Ip, Ching Tung [1 ]
Chau, Yu Kiu [1 ]
Jang, Jeong Gook [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hung Hom, Hong Kong, Peoples R China
[2] Incheon Natl Univ, Urban Sci Inst, Div Architecture & Urban Design, 119 Acad Ro, Incheon 22012, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Preplaced aggregate concrete; Two-stage concrete; Bond strength; Pull-off test; Silica fume; Coarse aggregate size; TO-OLD CONCRETE; TRANSITION ZONE; FLEXURAL BEHAVIOR; STRENGTH; SUBSTRATE; INCREASE;
D O I
10.1016/j.jobe.2023.108264
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, an experimental investigation was conducted to examine the bond strength of preplaced aggregate concrete (PAC) using a modified pull -off test that avoids the necessity for coring. The PAC was produced using 10 mm and 20 mm coarse aggregates and cement grout with and without the addition of silica fume (SF). Further, the bond strength of conventional concrete was examined to draw a comparison to PAC. The results demonstrate that although the compressive strength of PAC improved by around 20 % with the reduction in coarse aggregate size, the bond strength of PAC decreased by around 49 %. However, with the incorporation of SF, the bond strength improved by nearly 57 %, irrespective of the size of the coarse aggregate used. For the conventional concrete and PAC samples exhibiting similar compressive strength, the bond strength of the PAC was significantly lower than that of conventional concrete.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Mesoscale modelling of the FRP-concrete debonding mechanism in the pull-off test
    Wang, Xuan
    Zhao, Tianlin
    Guo, Jialong
    Zhang, Zihua
    Song, Xiaogang
    COMPOSITE STRUCTURES, 2023, 309
  • [22] Properties of Concrete Incorporating Ultrafine Fly Ash and Silica Fume
    Hossain, Akhter B.
    Shrestha, Sandeep
    Summers, James
    TRANSPORTATION RESEARCH RECORD, 2009, (2113) : 41 - 46
  • [23] Mechanical Properties and Durability of Cement Concrete Incorporating Silica Fume
    Lee, Seung-Tae
    Lee, Seung-Heun
    JOURNAL OF THE KOREAN CERAMIC SOCIETY, 2010, 47 (05) : 412 - 418
  • [24] Prediction on compressive strength concrete using modified pull-off testing method (MPTM)
    Yang, Suhang
    Xu, Zhifeng
    Bian, Zhengning
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 250 (250)
  • [25] Partial replacement of cement by ground granulated blast furnace slag and silica fume in two-stage concrete (preplaced aggregate concrete)
    Das, Kunal K.
    Lam, Eddie S. S.
    Tang, Ho H.
    STRUCTURAL CONCRETE, 2020, 22 (S1) : E466 - E473
  • [26] Mode I Fracture Toughness Determination of Rock and Concrete via Pull-Off Test
    Vítor Oliveira Santos Vizini
    Marcos Massao Futai
    Rock Mechanics and Rock Engineering, 2023, 56 : 1305 - 1319
  • [27] Factors Affecting Direct Tension Pull-Off Test Results of Materials Bonded to Concrete
    Harries, K. A.
    Sweriduk, M. E.
    ADVANCES IN CIVIL ENGINEERING MATERIALS, 2016, 5 (01): : 353 - 370
  • [28] Pull-off bond behavior of anchored random-chopped FRP composites bonded to concrete
    Wang, Zhen
    Khalid, Hammad R.
    Seo, J. H.
    Kang, Jingfu
    Lee, H. K.
    COMPOSITE STRUCTURES, 2018, 185 : 193 - 202
  • [29] Mode I Fracture Toughness Determination of Rock and Concrete via Pull-Off Test
    Santos Vizini, Vitor Oliveira
    Futai, Marcos Massao
    ROCK MECHANICS AND ROCK ENGINEERING, 2023, 56 (02) : 1305 - 1319
  • [30] Reliability of pull-off test for steel fiber reinforced self-compacting concrete
    Ghavidel, Reza
    Madandoust, Rahmat
    Ranjbar, Malek Mohammad
    MEASUREMENT, 2015, 73 : 628 - 639