Validating the safety of low-dose CTPA in pregnancy: results from the OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) Study

被引:2
|
作者
Gillespie, Ciara D. [1 ]
Yates, Andrew [1 ]
Hughes, Mark [1 ]
Ewins, Karl [2 ]
Mcmahon, Gabriella [3 ]
Hynes, John [1 ]
Murphy, Mark C. [1 ]
Galligan, Marie [4 ]
Vencken, Sebastian [4 ]
Alih, Ekele [4 ]
Varden, John [1 ]
Donnelly, Jennifer [3 ,5 ]
Bolster, Ferdia [1 ,5 ]
Rowan, Michael [6 ]
Foley, Shane [7 ]
Niainle, Fionnuala [2 ,5 ]
Macmahon, Peter J. [1 ,5 ]
机构
[1] Mater Misericordiae Univ Hosp, Dept Radiol, Whitty Bldg,North Circular Rd, Dublin 7, Ireland
[2] Mater Misericordiae Univ Hosp, Dept Haematol, Dublin D07R2WY, Ireland
[3] Rotunda Hosp, Dept Obstet, Dublin D01P5W9, Ireland
[4] Univ Coll Dublin, Clin Res Ctr, Sch Med, Dublin D04V1W8, Ireland
[5] Univ Coll Dublin, Sch Med, Dublin D04 V1W8, Ireland
[6] St James Hosp, Dept Med Phys, Dublin D08NHY1, Ireland
[7] Univ Coll Dublin, Sch Med, Radiog & Diagnost Imaging, Dublin D04V1W8, Ireland
关键词
Computed tomography angiography; Pregnancy; Radiation dosage; Pulmonary embolism; Venous thromboembolism; FEMALE BREAST; IMAGE QUALITY; EMBOLISM; REDUCTION; MANAGEMENT; ACCURACY; STANDARD; PROTOCOL;
D O I
10.1007/s00330-024-10593-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPulmonary embolism (PE) is a leading cause of pregnancy-related mortality. CT pulmonary angiogram (CTPA) is the first-line advanced imaging modality for suspected PE in pregnancy at institutes offering low-dose techniques; however, a protocol balancing safety with low dose remains undefined. The wide range of CTPA doses reported in pregnancy suggests a lack of confidence in implementing low-dose techniques in this group.PurposeTo define and validate the safety, radiation dose and image quality of a low-dose CTPA protocol optimised for pregnancy.Materials and methodsThe OPTICA study is a prospective observational study. Pregnant study participants with suspected PE underwent the same CTPA protocol between May 2018 and February 2022. The primary outcome, CTPA safety, was judged by the reference standard; the 3-month incidence of venous thromboembolism (VTE) in study participants with a negative index CTPA. Secondary outcomes defined radiation dose and image quality. Absorbed breast, maternal effective and fetal doses were estimated by Monte-Carlo simulation on gestation-matched phantoms. Image quality was assessed by signal-to-noise and contrast-to-noise ratios and a Likert score for pulmonary arterial enhancement.ResultsA total of 116 CTPAs were performed in 113 pregnant women of which 16 CTPAs were excluded. PE was diagnosed on 1 CTPA and out-ruled in 99. The incidence of recurrent symptomatic VTE was 0.0% (one-sided 95% CI, 2.66%) at follow-up. The mean absorbed breast dose was 2.9 +/- 2.1mGy, uterine/fetal dose was 0.1 +/- 0.2mGy and maternal effective dose was 1.4 +/- 0.9mSv. Signal-to-noise ratio (SNR) was 11.9 +/- 3.7. Contrast-to-noise ratio (CNR) was 10.4 +/- 3.5.ConclusionThe OPTICA CTPA protocol safely excluded PE in pregnant women across all trimesters, with low fetal and maternal radiation.Clinical relevanceOPTICA (Optimised CT Pulmonary Angiography in Pregnancy) is the first prospective study to define the achievable radiation dose, image-quality and safety of a low-dose CT pulmonary angiogram protocol optimised for pregnancy (NCT04179487). It provides the current benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population.Key Points center dot Despite the increased use of CT pulmonary angiogram in pregnancy, an optimised low-dose protocol has not been defined and reported doses in pregnancy continue to vary widely.center dot The OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) study prospectively defines the achievable dose, image quality and safety of a low-dose CT pulmonary angiogram protocol using widely available technology.center dot OPTICA provides a benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population.Key Points center dot Despite the increased use of CT pulmonary angiogram in pregnancy, an optimised low-dose protocol has not been defined and reported doses in pregnancy continue to vary widely.center dot The OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) study prospectively defines the achievable dose, image quality and safety of a low-dose CT pulmonary angiogram protocol using widely available technology.center dot OPTICA provides a benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population.Key Points center dot Despite the increased use of CT pulmonary angiogram in pregnancy, an optimised low-dose protocol has not been defined and reported doses in pregnancy continue to vary widely. center dot The OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) study prospectively defines the achievable dose, image quality and safety of a low-dose CT pulmonary angiogram protocol using widely available technology.center dot OPTICA provides a benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population.
引用
收藏
页码:4864 / 4873
页数:10
相关论文
共 50 条
  • [41] Detection of Pulmonary Embolism with Combined Ventilation-Perfusion SPECT and Low-Dose CT: Head-to-Head Comparison with Multidetector CT Angiography
    Gutte, Henrik
    Mortensen, Jann
    Jensen, Claus Verner
    Johnbeck, Camilla Bardram
    von der Recke, Peter
    Petersen, Claus Leth
    Kjaergaard, Jesper
    Kristoffersen, Ulrik Sloth
    Kjaer, Andreas
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (12) : 1987 - 1992
  • [42] Serial Imaging Over 1 Year By Perfusion (q) Scanning And CT Pulmonary Angiography (ctpa) after A First Episode Of Pulmonary Embolism (pe): Results Of The Elope Study
    Hirsch, A.
    Kahn, S.
    Akaberi, A.
    Anderson, D.
    Wells, P.
    Rodger, M.
    Solymoss, S.
    Kovacs, M.
    Rudski, L.
    Shimony, A.
    Dennie, C.
    Rush, C.
    Hernandez, P.
    Aaron, S. D.
    Granton, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [43] Low-dose aspirin usage during pregnancy: A retrospective structured electronic medical record data study
    Atwani, Rula
    Levy, Barbara
    Poorman, Greg
    Edmundson, Patrick
    Padmanabhan, Michael
    Boswell, Brandon
    Elfman, Amanda
    Saade, George R.
    Kawakita, Tetsuya
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (01) : S491 - S492
  • [44] Low-Dose Aspirin Use in Pregnancy in Patients with IBD with Risk Factors for Preeclampsia: A Retrospective Cohort Study
    Lockman, Sandhini
    Tandon, Parul
    DIGESTIVE DISEASES AND SCIENCES, 2024, : 2719 - 2720
  • [45] Lung Cancer Screening by Low-Dose CT Scan: Baseline Results of a French Prospective Study
    Leleu, Olivier
    Basille, Damien
    Auquier, Marianne
    Clarot, Caroline
    Hoguet, Estelle
    Petigny, Valerie
    Addi, Amale Ait
    Milleron, Bernard
    Chauffert, Bruno
    Berna, Pascal
    Jounieaux, Vincent
    CLINICAL LUNG CANCER, 2020, 21 (02) : 145 - 152
  • [46] LOW-DOSE IMATINIB IN THE TREATMENT OF SCLERODERMA PULMONARY INVOLVEMENT: RESULTS OF A PHASE II PILOT STUDY
    Fraticelli, P.
    Pomponio, G.
    Gabrielli, B.
    Riboldi, P.
    Ferraccioli, G.
    Giacomelli, R.
    Del Papa, N.
    Bombardieri, S.
    Malorni, W.
    Gerli, R.
    Lunardi, C.
    Faggioli, P.
    Corvetta, A.
    Valentini, G.
    Gabrielli, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2013, 72 : 652 - 653
  • [47] Could the YEARS algorithm be used to exclude pulmonary embolism during pregnancy? Data from the CT-PE-pregnancy study
    Langlois, Emilie
    Cusson-Dufour, Camille
    Moumneh, Thomas
    Elias, Antoine
    Meyer, Guy
    Lacut, Karine
    Schmidt, Jeannot
    Le Gall, Catherine
    Chauleur, Celine
    Glauser, Frederic
    Robert-Ebadi, Helia
    Righini, Marc
    Le Gal, Gregoire
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2019, 17 (08) : 1329 - 1334
  • [48] Comparative study of low-dose versus standard single-dose methotrexate: A novel approach for medical treatment of ectopic pregnancy
    Aydin, Gultekin A.
    Ozgen, Gulten
    Yavuz, Arzu
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2020, 46 (02) : 286 - 292
  • [49] Low-dose aspirin for the prevention of severe preeclampsia in patients with chronic kidney disease: a retrospective study This is the study for kidney and pregnancy ...
    Wang, Menglu
    Chen, Shi
    He, Yingdong
    Zhao, Minghui
    Yang, Huixia
    Chen, Qian
    JOURNAL OF NEPHROLOGY, 2021, 34 (05) : 1631 - 1639
  • [50] Lung tissue density measured by low-dose CT during pulmonary perfusion SPECT/CT as a tool for differentiation pulmonary embolism from chronic obstructive pulmonary disease - A pilot study
    Lang, Otto
    Balon, Helena R.
    Pichova, Renata
    Krizova, Hana
    Kunikova, Ivana
    COR ET VASA, 2013, 55 (06) : E492 - E496