Floor response spectra and seismic design method of electrical equipment installed on floor in indoor substation

被引:5
|
作者
Zhu, Wang [1 ]
Wu, Minger [1 ,2 ]
Xie, Qiang [1 ,2 ,3 ]
Xu, Junxin [1 ]
机构
[1] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Key Lab Performance Evolut & Control Engn Struct, Minist Educ, Shanghai 200092, Peoples R China
[3] Tongji Univ, Dept Struct Engn, Singping Rd 1239, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Indoor substation; Electrical equipment; Floor response spectra; Amplification factor; Seismic design method;
D O I
10.1016/j.soildyn.2023.108138
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Electrical equipment installed on floors is a typical type of nonstructural component in indoor substations, which could be subjected to earthquake loading during seismic events. To investigate the seismic design method of floor electrical equipment in indoor substations, simulation models of four whole-indoor substations comprising main control buildings and their floor electrical equipment were established. Seismic response spectrum analyses of main-attachment structures were performed with a high number of ground motions as inputs. Using mathematical statistics and data fitting methods, this research suggested the calculation formula of amplification factor of floor acceleration response spectrum. Specifically, when the periodic ratio of electrical equipment to main control building is in the range of 0.9-1.1, the system would produce a strong resonance-like effect with a peak spectral amplification factor. The floor response spectrum for seismic design was influenced by four factors: equipment importance category, floor position, damping ratio of electrical equipment, and torsion effect of main control building. Following that, a seismic design method especially applicable for electrical equipment installed on floor in indoor substation, which combines amplification factor and calculation method of seismic action indicated in the relevant specification, was presented. Lastly, a typical 220 kV whole-indoor substation was taken as an example to validate the accuracy of the design method highlighted in this article.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] STUDY ON DIFFERENCES IN FLOOR RESPONSE SPECTRA DUE TO THE SEISMIC INPUT APPROACH
    Bochert, Jana Sue
    Schau, Henry
    Schmitt, Timo
    PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 1, 2016,
  • [22] Relative Displacement Floor Spectra for Seismic Design of Non Structural Elements
    Calvi, Paolo Martino
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (07) : 1037 - 1059
  • [23] Floor spectra with equipment-structure-equipment interaction effects
    Suarez, Luis E.
    Singh, Mahendra P.
    Journal of Engineering Mechanics, 1989, 115 (02) : 247 - 264
  • [24] FLOOR SPECTRA WITH EQUIPMENT-STRUCTURE-EQUIPMENT INTERACTION EFFECTS
    SUAREZ, LE
    SINGH, MP
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1989, 115 (02): : 247 - 264
  • [25] The Timber Floor Seismic Design by Means Finite Element Method
    Namdar, Abdoullah
    Saimai, Shan
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2019, 5 (07): : 1557 - 1565
  • [26] Towards Seismic Design of Nonstructural Elements: Italian Code-Compliant Acceleration Floor Response Spectra
    Chichino, Beatrice
    Peloso, Simone
    Bolognini, Davide
    Moroni, Claudio
    Perrone, Daniele
    Brunesi, Emanuele
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [27] SEISMIC FLOOR SPECTRA BY MODE ACCELERATION APPROACH
    SINGH, MP
    SHARMA, AM
    JOURNAL OF ENGINEERING MECHANICS, 1985, 111 (11) : 1402 - 1419
  • [28] FLOOR RESPONSE SPECTRA WITH STRUCTURE EQUIPMENT INTERACTION EFFECTS BY A MODE SYNTHESIS APPROACH
    SUAREZ, LE
    SINGH, MP
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1987, 15 (02): : 141 - 158
  • [29] Floor discussion: Seismic performance and design
    Wu, JTH
    Ling, H
    Leshchinsky, D
    Allen, T
    Macklin, P
    Sandri, D
    Mirza, C
    Tatsuoka, F
    Ismeik, M
    Guler, E
    Bathurst, R
    Rimoldi, P
    MECHANICALLY STABILIZED BACKFILL, 1997, : 449 - 454
  • [30] A Multi-Mode Method for Estimation of Floor Response Spectra
    Pan, Xiaolan
    Zheng, Zhi
    Wang, Zhenyu
    JOURNAL OF EARTHQUAKE ENGINEERING, 2018, 22 (06) : 1111 - 1136