Phantom study for 90Y liver radioembolization dosimetry with a long axial field-of-view PET/CT

被引:2
|
作者
Mercolli, Lorenzo [1 ]
Zeimpekis, Konstantinos [1 ]
Prenosil, George A. [1 ]
Sari, Hasan [2 ]
Rathke, Hendrik G. [1 ]
Rominger, Axel [1 ]
Shi, Kunagyu [1 ]
机构
[1] Bern Univ Hosp, Univ Bern, Dept Nucl Med, Inselspital, Freiburgstr 18, CH-3010 Bern, Switzerland
[2] Adv Clin Imaging Technol, Siemens Healthcare AG, Lausanne, Switzerland
关键词
Dosimetry; Yttrium-90; Long axial field-of-view PET/CT; Monte Carlo simulations;
D O I
10.1016/j.ejmp.2024.103296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The physical properties of yttrium -90 (90Y) allow for imaging with positron emission tomography/computed tomography (PET/CT). The increased sensitivity of long axial field -of -view (LAFOV) PET/CT scanners possibly allows to overcome the small branching ratio for positron production from 90Y decays and to improve for the post -treatment dosimetry of 90Y of selective internal radiation therapy. Methods: For the challenging case of an image quality body phantom, we compare a full Monte Carlo (MC) dose calculation with the results from the two commercial software packages Simplicit90Y and Hermes. The voxel dosimetry module of Hermes relies on the 90Y images taken with a LAFOV PET/CT, while the MC and Simplicit90Y dose calculations are image independent. Results: The resulting doses from the MC calculation and Simplicit90Y agree well within the error margins. The image -based dose calculation with Hermes, however, consistently underestimates the dose. This is due to the mismatch of the activity distribution in the PET images and the size of the volume of interest. We found that only for the smallest phantom sphere there is a statistically significant dependence of the Hermes dose on the image reconstruction parameters and scan time. Conclusion: Our study shows that Simplicit90Y's local deposition model can provide a reliable dose estimate. On the other hand, the image based dose calculation suffers from the suboptimal reconstruction of the 90Y distribution in small structures.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Acceptance Testing of a Long Axial Field-of-View PET/ CT Scanner
    Willson, T.
    Chowdhury, A.
    Davis, N.
    Khan, J.
    Walford, O.
    Natarajan, H.
    McCool, D.
    Holman, B. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S723 - S723
  • [22] Expert consensus on workflow of PET/CT with long axial field-of-view
    Liu, Guobing
    Gu, Yushen
    Sollini, Martina
    Lazar, Alexandra
    Besson, Florent L.
    Li, Sijin
    Wu, Zhifang
    Nardo, Lorenzo
    Al-Ibraheem, Akram
    Zheng, Jiefu
    Kulkarni, Harshad R.
    Rominger, Axel
    Fan, Wei
    Zhu, Xiaohua
    Zhao, Xinming
    Wu, Hubing
    Liu, Jianjun
    Li, Biao
    Cheng, Zhaoping
    Wang, Ruimin
    Xu, Baixuan
    Agostini, Denis
    Tang, Han
    Tan, Lijie
    Yang, Zhi
    Huo, Li
    Gu, Jianying
    Shi, Hongcheng
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (03) : 1038 - 1049
  • [23] Long Axial Field-of-View (LAFOV) PET/CT in Prostate Cancer
    Sachpekidis, Christos
    Dimitrakopoulou-Strauss, Antonia
    SEMINARS IN NUCLEAR MEDICINE, 2025, 55 (01) : 67 - 75
  • [24] 90Y Liver Radioembolization Imaging Using Amplitude-Based Gated PET/CT
    Osborne, Dustin R.
    Acuff, Shelley
    Neveu, Melissa
    Kaman, Austin
    Syed, Mumtaz
    Fu, Yitong
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (05) : 373 - 374
  • [25] A method to correct breathing effects in the dosimetry of liver radioembolization with 90Y microspheres
    Iaccarino, G.
    D'Andrea, M.
    Cazzato, M.
    Ungania, S.
    Pizzi, G.
    Vallati, G. E.
    Sciuto, R.
    Maini, C. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S180 - S180
  • [26] A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheresThe QUEST Phantom Study
    Kathy P. Willowson
    Michael Tapner
    Dale L. Bailey
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1202 - 1222
  • [27] Comparison of 99mTc-MAA SPECT/CT predictive dosimetry and 90Y PET/CT posttreatment dosimetry in Radioembolization of Hepatic Tumours
    Ferrando, O.
    Foppiano, F.
    Ciarmiello, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S281 - S281
  • [28] Is PET/MRI better than PET/CT for imaging and dosimetry after radioembolization with Yttrium-90 (90Y) microspheres in the treatment of hepatocellular
    Knesaurek, K.
    Pasik, S. D.
    Kim, E.
    Heiba, S.
    Kostakoglu, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S575 - S576
  • [29] Clinical applications of long axial field-of-view PET/CT scanners in oncology
    Urso, Luca
    Frantellizzi, Viviana
    De Vincentis, Giuseppe
    Schillaci, Orazio
    Filippi, Luca
    Evangelista, Laura
    CLINICAL AND TRANSLATIONAL IMAGING, 2023, 11 (04) : 365 - 380
  • [30] Clinical applications of long axial field-of-view PET/CT scanners in oncology
    Luca Urso
    Viviana Frantellizzi
    Giuseppe De Vincentis
    Orazio Schillaci
    Luca Filippi
    Laura Evangelista
    Clinical and Translational Imaging, 2023, 11 : 365 - 380