Impact of diastolic pulmonary gradient and pulmonary vascular remodeling on survival after left ventricular assist device implantation and heart transplantation

被引:0
|
作者
Laimoud, Mohamed [1 ,2 ]
Hakami, Emad [3 ]
Maghirang, Mary Jane [3 ]
Mohamed, Tahir [4 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Cardiovasc Crit Care Dept, Riyadh, Saudi Arabia
[2] Cairo Univ, Crit Care Med Dept, Cairo, Egypt
[3] King Faisal Specialist Hosp & Res Ctr, Cardiovasc Nursing Dept, Riyadh, Saudi Arabia
[4] King Faisal Specialist Hosp & Res Ctr, Cardiovasc Med Dept, Riyadh, Saudi Arabia
来源
EGYPTIAN HEART JOURNAL | 2023年 / 75卷 / 01期
关键词
Diastolic pulmonary gradient (DPG); Pulmonary vascular resistance (PVR); Transpulmonary gradient (TPG); Heart transplantation; Left ventricular assist device (LVAD); HeartMate III; Right ventricular failure (RVF); Mortality; WEDGE PRESSURE-GRADIENT; HYPERTENSION; CANDIDATES; GUIDELINES; RESISTANCE; DIAGNOSIS; SOCIETY; DISEASE;
D O I
10.1186/s43044-023-00428-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The left ventricular assist devices (LVADs) are increasingly used for advanced heart failure as a bridge to heart transplantation or as a destination therapy. The aim of this study was to investigate the changes of diastolic pulmonary gradient (DPG), pulmonary vascular resistance (PVR) and transpulmonary gradient (TPG) after LVAD implantation and their impact on survival after LVAD and heart transplantation.Results A total of 73 patients who underwent LVAD (HeartMate III) implantation between 2016 and 2022 were retrospectively studied. According to pre-LVAD catheterization, 49 (67.1%) patients had DPG < 7 mmHg and 24 (32.9%) patients had DPG >= 7 mmHg. The patients with a pre-VAD DPG >= 7 mmHg had higher frequencies of right ventricular (RV) failure (p < 0.001), RVAD insertion (p < 0.001), need for renal replacement therapy (p = 0.002), total mortality (p = 0.036) and on-VAD mortality (p = 0.04) with a longer ICU stay (p = 0.001) compared to the patients with DPG < 7 mmHg. During the follow-up period of 38 (12-60) months, 24 (32.9%) patients died. Pre-LVAD DPG >= 7 mmHg (adjusted HR 1.83, 95% CI 1.21-6.341, p = 0.039) and post-LVAD DPG >= 7 mmHg (adjusted HR 3.824, 95% CI 1.482-14.648, p = 0.002) were associated with increased risks of mortality. Neither pre-LVAD TPG >= 12 (p = 0.505) nor post-LVAD TPG >= 12 mmHg (p = 0.122) was associated with an increased risk of death. Pre-LVAD PVR >= 3 WU had a statistically insignificant risk of mortality (HR 2.35, 95% CI 0.803-6.848, p = 0.119) while post-LVAD PVR >= 3 WU had an increased risk of death (adjusted HR 2.37, 95% CI 1.241-7.254, p = 0.038). For post-transplantation mortality, post-LVAD DPG >= 7 mmHg (p = 0.55), post-LVAD TPG >= 12 mmHg (p = 0.85) and PVR >= 3 WU (p = 0.54) did not have statistically increased risks. The logistic multivariable regression showed that post-LVAD PVR >= 3 WU (p = 0.013), post-LVAD DPG >= 7 mmHg (p = 0.026) and RVF (p = 0.018) were the predictors of mortality after LVAD implantation. Pre-LVAD DPG >= 7 mmHg (p < 0.001) and pre-LVAD PVR >= 3 WU (p = 0.036) were the predictors of RVF after LVAD implantation.Conclusions Persistently high DPG was associated with right ventricular failure and mortality after LVAD implantation rather than after heart transplantation. DPG is a better predictor of pulmonary vascular remodeling compared to TPG and PVR. Further larger prospective studies are required in this field due to the growing numbers of patients with advanced heart failure, as possible candidates for LVAD implantation, and limitations of heart transplantation.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Pulmonary Arterial Compliance Improves Rapidly After Left Ventricular Assist Device Implantation
    Masri, S. Carolina
    Tedford, Ryan J.
    Colvin, Monica M.
    Leary, Peter J.
    Cogswell, Rebecca
    ASAIO JOURNAL, 2017, 63 (02) : 139 - 143
  • [32] Left ventricular assist device for treatment of severe pulmonary hypertension in heart transplantation candidates
    Gomez Bueno, M.
    Segovia-Cubero, J.
    Hernandez-Perez, F.
    Sayago-Silva, I.
    Jaramillo, N.
    Gonzalez-Roman, A.
    Serrano-Fiz, S.
    Garcia-Montero, C.
    Burgos-Lazaro, R.
    Alonso-Pulpon, L.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 335 - 335
  • [33] Humoral and hemodynamic responses after left ventricular assist device implantation and heart transplantation
    Wagner, Frank D.
    Buz, Semih
    Zais, Hans
    Stasch, Johannes Peter
    Hetzer, Roland
    Hocher, Berthold
    EXPERIMENTAL BIOLOGY AND MEDICINE, 2006, 231 (06) : 861 - 864
  • [34] Duration of Left Ventricular Assist Device Support Does Not Impact Survival After US Heart Transplantation
    Grimm, Joshua C.
    Magruder, J. Trent
    Crawford, Todd C.
    Fraser, Charles D., III
    Plum, William G.
    Sciortino, Christopher M.
    Higgins, Robert S.
    Whitman, Glenn J. R.
    Shah, Ashish S.
    ANNALS OF THORACIC SURGERY, 2016, 102 (04): : 1206 - 1212
  • [35] Impact of Left Ventricular Assist Device Exchange on Outcomes After Heart Transplantation
    Suarez-Pierre, Alejandro
    Zhou, Xun
    Lui, Cecillia
    Grimm, Joshua C.
    Hsu, Steven
    Choi, Chun W.
    Kilic, Ahmet
    ANNALS OF THORACIC SURGERY, 2020, 109 (01): : 78 - 84
  • [36] Does pretransplant left ventricular assist device therapy improve results after heart transplantation in patients with elevated pulmonary vascular resistance?
    Liden, Hans
    Haraldsson, Asa
    Ricksten, Sven-Erik
    Kjellman, Ulf
    Wikund, Lars
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (06) : 1029 - 1035
  • [37] Differentiated impact of pulmonary hypertension on outcome after left ventricular assist device implantation and tricuspid valve repair
    Volevski, Lachezar A.
    Ben Taieb, Olfa
    Talipov, Ildar
    Vasiloi, Ion
    Glueck, Alannah C.
    Andrasi, Terezia B.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2023, 46 (02): : 85 - 92
  • [38] Right ventricular failure after left ventricular assist device implantation with concomitant pulmonary embolectomy needing right ventricular assist device support in a patient with terminal heart failure and asymptomatic pulmonary thrombus
    Stepanenko, Alexander
    Potapov, Evgenij V.
    Krabatsch, Thomas
    Hetzer, Roland
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (01) : 154 - 155
  • [39] Impact of Postoperative Liver Dysfunction on Survival After Left Ventricular Assist Device Implantation
    Majumder, Kaustav
    Spratt, John R.
    Holley, Christopher T.
    Roy, Samit S.
    Cogswell, Rebecca J.
    Liao, Kenneth
    John, Ranjit
    ANNALS OF THORACIC SURGERY, 2017, 104 (05): : 1556 - 1563
  • [40] Pulmonary Vascular Hemodynamics Improvement with Left Ventricular Assist Devices Unloading Is Sustained after Heart Transplantation.
    Saidi, A.
    Wever-Pinzon, O.
    Stehlik, J.
    Gilbert, E.
    Alharethi, R.
    Selzman, C.
    Reid, B.
    Budge, D.
    Kfoury, A.
    Bader, F.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 : 458 - 458