Determination of Polystyrene Microplastic in Soil by Pyrolysis - Gas Chromatography - Mass Spectrometry (pyr-GC-MS)

被引:4
|
作者
de Carvalho, Aline Reis [1 ,5 ]
Mathieu, Olivier [1 ]
Thevenot, Mathieu [1 ]
Amiotte-Suchet, Philippe [1 ]
Bertrand, Xavier [2 ]
Beugnot, Jean-Charles [3 ]
Karbowiak, Thomas [4 ]
Celle, Helene [2 ]
机构
[1] Univ Bourgogne, CNRS, UMR 6282, Biogeosci, Dijon, France
[2] UBFC, Lab Chronoenvironm LCE, CNRS, UMR 6249, Besancon, France
[3] UBFC, CNRS, UMR 6174, FEMTO ST Inst, Besancon, France
[4] Univ Bourgogne Franche Comte, Inst Agro Dijon, PAM UMR 02 102, Dijon, France
[5] Flemish Inst Technol Res VITO, SCT GOAL, B-2400 Mol, Belgium
关键词
Polystyrene microplastic; pyrolysates; pyrolysis - gas chromatography - mass spectrometry (pyr-GC-MS); soil analysis; ENVIRONMENTAL-SAMPLES; THERMAL-DEGRADATION; MOLECULAR-WEIGHT; ORGANIC-MATTER; CHEMICAL CHARACTERIZATION; IDENTIFICATION; SEDIMENTS; MICRO(NANO)PLASTICS; QUANTIFICATION; POLYMERS;
D O I
10.1080/00032719.2023.2262633
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pyrolysis-gas chromatography-mass spectrometry (pyr-GC-MS) is emerging as a promising alternative for the detection and quantification of microplastic pollution. For a robust quantification it is essential to improve our understanding of interferences in the pyrolysis of microplastics. Here we investigate the effects of different soil matrices, mainly differing by their organic carbon content (Corg, 1.0-13.6%), and of the polymer molecular weight (Mw) on the pyr-GC-MS analysis of polystyrene (PS) microplastics. In addition, we evaluated the effectiveness of adding poly(4-fluorostyrene) (PSF) as internal standard to circumvent the matrix effects. The three main markers of PS pyrolysis, i.e., styrene, styrene-dimer and styrene-trimer, were monitored. The ratio between the dimer and the trimer significantly varied between the matrices and tended to decrease with the increasing of the Corg in the soil, mainly due to an increased trimer formation. A strong matrix effect affected the slope of the calibration curves by 2 to 8-fold and was correlated with the Corg in the soils. This effect was mitigated when the areas of the markers were normalized by the area of the corresponding marker of PSF. PS of low Mw (Mw 35,000) presented a reduced formation of the three markers compared to PS of high Mw (Mw 400,000), and styrene-dimer was proportionally less formed than the other two markers. Differences in the slopes of calibration curves depended on the marker chosen, highlighting the relevance of selecting the pyrolysis marker in the quantification of microplastics using pyr-GC-MS.
引用
收藏
页码:1576 / 1594
页数:19
相关论文
共 50 条
  • [31] DETERMINATION OF ANILINE IN CONTAMINATED FOOD OIL BY USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY (GC/MS)
    TODD, GD
    HILL, RH
    BERNERT, JT
    KILBOURNE, EM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 194 : 71 - ENVR
  • [32] DETERMINATION OF VOLATILE AROMA COMPOUNDS OF GANODERMA LUCIDUM BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (HS-GC/MS)
    Taskin, Hatira
    Kafkas, Ebru
    Cakiroglu, Ozgun
    Buyukalaca, Saadet
    AFRICAN JOURNAL OF TRADITIONAL COMPLEMENTARY AND ALTERNATIVE MEDICINES, 2013, 10 (02) : 353 - 355
  • [33] DETERMINATION OF DIMETHYL SULPHIDE IN BREWERY SAMPLES BY HEADSPACE GAS CHROMATOGRAPHY MASS SPECTROMETRY (HS-GC/MS)
    Stafisso, A.
    Marconi, O.
    Perretti, G.
    Fantozzi, P.
    ITALIAN JOURNAL OF FOOD SCIENCE, 2011, 23 (01) : 19 - 27
  • [34] Rapid Determination of Aziridine in Leathers by Headspace-gas Chromatography/Mass Spectrometry (HS-GC-MS)
    Yu, Lingyun
    Shuai, Peiqiang
    Hu, Jiagntao
    Wu, Mengru
    Li, Xiaojin
    Zhou, Lei
    Dong, Wei
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2017, 101 (05): : 227 - 230
  • [35] Simultaneous determination of 19 bromophenols by gas chromatography-mass spectrometry (GC-MS) after derivatization
    Liu, Yanwei
    Hou, Xingwang
    Li, Xiaoying
    Liu, Jiyan
    Jiang, Guibin
    TALANTA, 2024, 274
  • [36] Quantitative determination of wine polysaccharides by gas chromatography-mass spectrometry (GC-MS) and size exclusion chromatography (SEC)
    Guadalupe, Zenaida
    Martinez-Pinilla, Olga
    Garrido, Alvaro
    David Carrillo, Jose
    Ayestaran, Belen
    FOOD CHEMISTRY, 2012, 131 (01) : 367 - 374
  • [37] Determination of Hexabromocyclododecane in Expanded Polystyrene and Extruded Polystyrene Foam by Gas Chromatography-Mass Spectrometry
    Mao, Tianao
    Wang, Haoyang
    Peng, Zheng
    Ni, Taotao
    Jia, Tianqi
    Lei, Rongrong
    Liu, Wenbin
    MOLECULES, 2021, 26 (23):
  • [38] CONNECTION OF GAS CHROMATOGRAPHY, PYROLYSIS AND MASS SPECTROMETRY
    VANCAUWE.K
    INDUSTRIE CHIMIQUE BELGE-BELGISCHE CHEMISCHE INDUSTRIE, 1971, 36 (11): : 967 - &
  • [39] A COMPARISON OF PYROLYSIS GAS CHROMATOGRAPHY AND MASS SPECTROMETRY
    KELLEY, JD
    WOLF, CJ
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1970, 8 (10) : 583 - &
  • [40] Microplastics in three types of human arteries detected by pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS)
    Liu, Sheng
    Wang, Chenyang
    Yang, Yunxiao
    Du, Zhiyong
    Li, Li
    Zhang, Meng
    Ni, Siyao
    Yue, Zhijian
    Yang, Kexin
    Wang, Yu
    Li, Xinxin
    Yang, Yaochen
    Qin, Yanwen
    Li, Jianrong
    Yang, Yaoguo
    Zhang, Ming
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 469