Real-time multiple signal amplification self-powered biosensing platform for ultrasensitive detection of MicroRNA

被引:64
|
作者
Wang, Fu-Ting [7 ]
Hou, Yang-Yang [6 ]
Tan, Xuecai [1 ,2 ,3 ,4 ,5 ]
Huang, Ke-Jing [1 ,2 ,3 ,4 ,5 ]
Xu, Jing [6 ]
Cai, Ren [7 ]
机构
[1] Guangxi Minzu Univ, Sch Chem & Chem Engn, Nanning 530008, Peoples R China
[2] State Ethn Affairs Commiss, Key Lab Chem & Engn Forest Prod, Nanning 530008, Peoples R China
[3] Guangxi Key Lab Chem & Engn Forest Prod, Nanning 530008, Peoples R China
[4] Guangxi Collaborat Innovat Ctr Chem & Engn Forest, Nanning 530008, Peoples R China
[5] Key Lab Guangxi Coll & Univ Food Safety & Pharmace, Nanning 530008, Peoples R China
[6] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
[7] Hunan Univ, Coll Mat Sci & Engn, Coll Chem & Chem Engn, Coll Biol,Mol Sci & Biomed Lab,State Key Lab Chemo, Changsha 410082, Peoples R China
来源
关键词
Real-time detection; Self-powered biosensing platform; MicroRNA-21; Target-induced recycling double amplification; strategy; Multiple signal amplification; ELECTROCHEMICAL BIOSENSOR; GOLD NANOPARTICLES; METHYLENE-BLUE; CANCER;
D O I
10.1016/j.bios.2022.114933
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A real-time self-powered biosensor is designed for ultrasensitive detection of microRNA-21 based on electro-chemical energy device capacitor and target-induced recycling double amplification strategy, which greatly improves the output signal by converting a small number of targets into two glucose oxidase labeled output strand DNAs, and the squeezed-out output strand is recycled by the cathode to fix more signal [Ru(NH3)6]3+ to further improve the detection signal. A digital multimeter (DMM) is connected to computer for real-time dis-playing the output signal of the self-powered biosensing system, which improves the accuracy of the sensing platform. The sensitivity of the proposed biosensor is 116.15 mu A/pM for target microRNA-21, which is 32.26 times higher than that of pure EBFC (3.6 mu A/pM). The target concentration is proportional to the open-circuit voltage value in a wide linear range of 0.1-10000 fM with a low detection limit of 0.04 fM (S/N = 3). The method shows high sensitivity and excellent selectivity, and can be applied to detect tumor marker microRNA-21 in biological matrix.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A self-powered cathodic molecular imprinting ultrasensitive photoelectrochemical tetracycline sensor via ZnO/C photoanode signal amplification
    Pan, Qinghong
    Zhang, Huafang
    Liu, Qiaoling
    Huang, Donghong
    Yang, Da-Peng
    Jiang, Tianjia
    Sun, Shuyang
    Chen, Xiangrong
    CHINESE CHEMICAL LETTERS, 2025, 36 (01)
  • [42] A self-powered cathodic molecular imprinting ultrasensitive photoelectrochemical tetracycline sensor via ZnO/C photoanode signal amplification
    Qinghong Pan
    Huafang Zhang
    Qiaoling Liu
    Donghong Huang
    DaPeng Yang
    Tianjia Jiang
    Shuyang Sun
    Xiangrong Chen
    Chinese Chemical Letters, 2025, 36 (01) : 568 - 573
  • [43] A self-powered biosensor with cascade amplification capability facilitates ultra-sensitive detection of microRNA biomarkers
    Xu, Jing
    Luo, Xinqi
    Chen, Hanxiao
    Guo, Bin
    Jia, Lijun
    Wang, Fu
    BIOSENSORS & BIOELECTRONICS, 2025, 275
  • [44] Tailoring high-energy self-powered sensing system by Walker-mediated CRISPR/Cas12a cascade signal amplification and hybridization chain reaction for ultrasensitive microRNA detection
    Song, Yujie
    Shi, Jinyue
    Wu, Yeyu
    Huang, Ke-Jing
    Tan, Xuecai
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 399
  • [45] Target-assisted FRET signal amplification for ultrasensitive detection of microRNA
    Wang, Bin
    You, Zheng
    Ren, Dahai
    ANALYST, 2019, 144 (07) : 2304 - 2311
  • [46] Hierarchical Porous Metal-Organic Framework as Biocatalytic Microreactor for Enzymatic Biofuel Cell-Based Self-Powered Biosensing of MicroRNA Integrated with Cascade Signal Amplification
    Yan, Yongcun
    Guo, Li
    Geng, Hongyan
    Bi, Sai
    SMALL, 2023, 19 (35)
  • [47] Self-Powered Implantable Skin-Like Glucometer for Real-Time Detection of Blood Glucose Level In Vivo
    Zhang, Wanglinhan
    Zhang, Linlin
    Gao, Huiling
    Yang, Wenyan
    Wang, Shuai
    Xing, Lili
    Xue, Xinyu
    NANO-MICRO LETTERS, 2018, 10 (02)
  • [48] Self-Powered Implantable Skin-Like Glucometer for Real-Time Detection of Blood Glucose Level In Vivo
    Wanglinhan Zhang
    Linlin Zhang
    Huiling Gao
    Wenyan Yang
    Shuai Wang
    Lili Xing
    Xinyu Xue
    Nano-Micro Letters, 2018, 10
  • [49] Self-Powered Implantable Skin-Like Glucometer for Real-Time Detection of Blood Glucose Level In Vivo
    Wanglinhan Zhang
    Linlin Zhang
    Huiling Gao
    Wenyan Yang
    Shuai Wang
    Lili Xing
    Xinyu Xue
    Nano-Micro Letters, 2018, 10 (02) : 151 - 161
  • [50] Towards a disposable real-time DNA biosensing platform
    Williams, LD
    Bishop, J
    Blair, S
    Peters, DW
    Okandan, M
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS II, 2004, 5345 : 61 - 67