An improved single-terminal fault location method for inverter grid-connected system based on active control

被引:6
|
作者
Song, Guobing [1 ]
Chang, Peng [1 ]
Hou, Junjie [2 ]
Xiong, Fuzhi [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat Power Equipment, Xian 710049, Shaanxi, Peoples R China
[2] Xinjiang Univ, Sch Elect Engn, Urumqi 830046, Xinjiang, Peoples R China
关键词
Single -terminal fault location; Active control; Non -iterative algorithm; Inverter grid-connected system; TRAVELING-WAVE;
D O I
10.1016/j.epsr.2022.109100
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Single-terminal fault location methods are easily affected by fault resistance and system parameters, and they always utilize iterative algorithm to solve fault distance. To improve their performance, an improved single -terminal fault location method for inverter system based on active control is proposed in this article, which can be used for symmetrical and asymmetrical faults. First, the problem that influences the performance of fault location method is analyzed. And to solve it, a control strategy that can create two fault statuses during fault stage is proposed. Then, using the electrical quantities under the different fault stages, two irrelevant equation groups can be established, and fault distance can be solved by single-terminal data. The PSCAD/EMTDC results demonstrate that the method can achieve fault location accurately, which just requires a small amount of calculation. And it is less affected by fault resistance and system parameters.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Single-phase grid-connected photovoltaic system based on boost inverter
    Xiong, Yuansheng
    Qian, Suxiang
    Xu, Jianming
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [42] Performance Analysis of Three-Phase Grid-Connected Inverter System with Improved SMC-based MPC Control Method
    Demir, Ekrem
    Gulbudak, Ozan
    2024 IEEE KANSAS POWER AND ENERGY CONFERENCE, KPEC 2024, 2024,
  • [43] A Single-Terminal Fault Location Method for HVDC Transmission Lines Based on a Hybrid Deep Network
    Wang, Lei
    He, Yigang
    Li, Lie
    ELECTRONICS, 2021, 10 (03) : 1 - 28
  • [44] The control method of grid-connected inverter based on novel proportion resonant controller
    Zhao, Xin
    Jin, Xinmin
    Tang, Fen
    Liang, Hui
    Wu, Xuezhi
    Tong, Yibin
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2014, 29 : 266 - 272
  • [45] A Fault Detection Method of Microgrids With Grid-Connected Inverter Interfaced Distributed Generators Based on the PQ Control Strategy
    Zhang, Fan
    Mu, Longhua
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (05) : 4816 - 4826
  • [46] A Control Method with Grid Disturbances Suppression for a single-phase LCL-Filter-Based Grid-Connected Inverter
    Teng Guofei
    Xiao Guochun
    Zhang Zhibo
    Lu Yong
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 1489 - 1493
  • [47] Research on Control Method of Solar Grid-connected Inverter with Single DC Power Supply
    Hua, Zhang
    Wang, Rong
    Zhu Zhongni
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [48] Study on Control Method for the Grid-Connected Inverter with LCL Filter
    Wang, Cunping
    Sun, Jian
    PROCEEDINGS OF 2014 IEEE WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS (WARTIA), 2014, : 1337 - 1341
  • [49] Modeling, control and analysis of cascaded inverter based grid-connected photovoltaic system
    Kumar, Nayan
    Saha, Tapas Kumar
    Dey, Jayati
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 78 : 165 - 173
  • [50] Lyapunov-Based Control Strategy for Grid-Connected Inverter with Improved Transient Response
    Wang, Jinhao
    Yang, Chaoying
    Wu, Yulong
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATIC CONTROL, 2016, 367 : 773 - 782