A Controlled Variable Study of the Biomechanical Properties of the Proximal Femur before and after Cancellous Bone Removal

被引:2
|
作者
Wang, Haicheng [1 ]
Ding, Kai [2 ]
Zhang, Yifan [2 ]
Ren, Chuan [2 ]
Huo, Haoyu [2 ]
Zhu, Yanbin [2 ]
Zhang, Qi [2 ]
Chen, Wei [2 ,3 ,4 ]
机构
[1] CangZhou Hosp Integrated TCM WM Hebei, Cangzhou City, Peoples R China
[2] Hebei Med Univ, Hosp 3, Dept Orthoped Surg, 139 Ziqiang Rd, Shijiazhuang 050051, Peoples R China
[3] Hebei Med Univ, Hosp 3, NHC Key Lab Intelligent Orthoped Equipment, Shijiazhuang, Peoples R China
[4] Key Lab Biomech Hebei Prov, Shijiazhuang, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
Biomechanics; Bone density; Cancellous bone; Proximal femur; FEMORAL-NECK; STRENGTH; DISTRIBUTIONS; RESOLUTION; FRACTURES; AGE;
D O I
10.1111/os.14044
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The biomechanical characteristics of proximal femoral trabeculae are closely related to the occurrence and treatment of proximal femoral fractures. Therefore, it is of great significance to study its biomechanical effects of cancellous bone in the proximal femur. This study examines the biomechanical effects of the cancellous bone in the proximal femur using a controlled variable method, which provide a foundation for further research into the mechanical properties of the proximal femur. Methods: Seventeen proximal femoral specimens were selected to scan by quantitative computed tomography (QCT), and the gray values of nine regions were measure to evaluated bone mineral density (BMD) using Mimics software. Then, an intact femur was fixed simulating unilateral standing position. Vertical compression experiments were then performed again after removing cancellous bone in the femoral head, femoral neck, and intertrochanteric region, and data were recorded. According to the controlled variable method, the femoral head, femoral neck, and intertrochanteric trabeculae were sequentially removed based on the axial loading of the intact femur, and the displacement and strain changes of the femur samples under axial loading were recorded. Gom software was used to measure and record displacement and strain maps of the femoral surface. Results: There was a statistically significant difference in anteroposterior displacement of cancellous bone destruction in the proximal femur (p < 0.001). Proximal femoral bone mass explained 77.5% of the strength variation, in addition proximal femoral strength was mainly affected by bone mass at the level of the upper outer, lower inner, lower greater trochanter, and lesser trochanter of the femoral head. The normal stress conduction of the proximal femur was destroyed after removing cancellous bone, the stress was concentrated in the femoral head and lateral femoral neck, and the femoral head showed a tendency to subside after destroying cancellous bone. Conclusion: The trabecular removal significantly altered the strain distribution and biomechanical strength of the proximal femur, demonstrating an important role in supporting and transforming bending moment under the vertical load. In addition, the strength of the proximal femur mainly depends on the bone density of the femoral head and intertrochanteric region.
引用
收藏
页码:1215 / 1229
页数:15
相关论文
共 50 条
  • [21] EVALUATION OF THE PROXIMAL PORTION OF THE FEMUR AS AN AUTOGENOUS CANCELLOUS BONE DONOR SITE IN DOGS
    TREVOR, PB
    SMITH, MM
    STEVENSON, S
    CARRIG, CB
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1992, 53 (09) : 1599 - 1603
  • [22] Femoroplasty - augmentation of the proximal femur with a composite bone cement - feasibility, biomechanical properties and osteosynthesis potential
    Beckmann, J.
    Ferguson, S. J.
    Gebauer, A.
    Luering, C.
    Gasser, B.
    Heini, P.
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (07) : 755 - 764
  • [23] In vitro biomechanical study of femoral torsion disorders: effect on tibial proximal epiphyseal cancellous bone deformation
    Stéphane Sobczak
    Bruno Baillon
    Véronique Feipel
    Serge Van Sint Jan
    Patrick Salvia
    Marcel Rooze
    Surgical and Radiologic Anatomy, 2011, 33 : 439 - 449
  • [24] Proximal tibiotarsal cancellous bone mechanical properties in broilers
    Capps, SG
    Bottcher, RW
    Abrams, CF
    Scheideler, SE
    TRANSACTIONS OF THE ASAE, 1997, 40 (05): : 1469 - 1473
  • [25] In vitro biomechanical study of femoral torsion disorders: effect on tibial proximal epiphyseal cancellous bone deformation
    Sobczak, Stephane
    Baillon, Bruno
    Feipel, Veronique
    Van Sint Jan, Serge
    Salvia, Patrick
    Rooze, Marcel
    SURGICAL AND RADIOLOGIC ANATOMY, 2011, 33 (05) : 439 - 449
  • [26] A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures
    Singh, Ashutosh Kumar
    Narsaria, N.
    Gupta, R. K.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (10): : 2050 - 2053
  • [27] Osteocyte density and histomorphometric parameters in cancellous bone of the proximal femur in five mammalian species
    Mullender, MG
    Huiskes, R
    Versleyen, H
    Buma, P
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (06) : 972 - 979
  • [28] Histological and biomechanical study of impacted cancellous allografts with cement in the femur: a canine model
    O. Omoto
    Y. Yasunaga
    N. Adachi
    M. Deie
    M. Ochi
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 1357 - 1364
  • [29] Stress fracture of the proximal femur after screw removal
    Velkes, S
    Nerubay, J
    Lokiec, F
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1996, 115 (01) : 61 - 62
  • [30] Histological and biomechanical study of impacted cancellous allografts with cement in the femur: a canine model
    Omoto, O.
    Yasunaga, Y.
    Adachi, N.
    Deie, M.
    Ochi, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (12) : 1357 - 1364