Infrared Thermal Image Instance Segmentation Method for Power Substation Equipment Based on Visual Feature Reasoning

被引:11
|
作者
Zhao, Zhenbing [1 ,2 ,3 ]
Feng, Shuo [4 ]
Zhai, Yongjie [2 ,5 ]
Zhao, Wenqing [2 ,5 ]
Li, Gang [2 ,5 ]
机构
[1] North China Elect Power Univ, Dept Elect & Commun Engn, Baoding 071003, Peoples R China
[2] North China Elect Power Univ, Engn Res Ctr Intelligent Comp Complex Energy Syst, Minist Educ, Baoding 071003, Peoples R China
[3] North China Elect Power Univ, Hebei Key Lab Power Internet Things Technol, Baoding 071003, Peoples R China
[4] North China Elect Power Univ, Sch Elect & Elect Engn, Baoding 071003, Peoples R China
[5] North China Elect Power Univ, Sch Control & Comp Engn, Baoding 071000, Peoples R China
基金
中国国家自然科学基金;
关键词
Substations; Feature extraction; Visualization; Image segmentation; Object detection; Deep learning; Cognition; Infrared image; instance segmentation; power substation equipment; SOLOv2; visual feature reasoning;
D O I
10.1109/TIM.2023.3322998
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The accurate infrared thermal image instance segmentation of substation equipment is a prerequisite for intelligent analysis of its temperature status. To address the issues of low accuracy and false detection in the existing substation instance segmentation methods, we propose a visual feature reasoning-based substation infrared thermal image instance segmentation method to compensate for the limitations of deep learning methods and improve the instance segmentation accuracy. We propose utilizing distinctive visual features as a priori knowledge for three types of substation equipment and construct a two-branch instance segmentation model (FR-SOLOv2) based on power domain expertise and visual feature reasoning. FR-SOLOv2 comprises distinctive visual feature extraction and reasoning network (FR) as well as a substation equipment image segmentation network (SOLOv2). FR combines power domain knowledge and visual feature reasoning to provide accurate localization and classification information for each substation device. SOLOv2 accomplishes segmenting substation devices in infrared images based on residual networks and feature fusion pyramids. The test results well demonstrate the superiority of our model for instance segmentation of the infrared image of substation equipment. Additionally, FR-SOLOv2 demonstrates an average accuracy of 83.18% on the substation equipment infrared image dataset, a significant improvement of 13.5% compared to the baseline model. The method relying on prior knowledge for visual feature reasoning on deep learning methods also presents a new approach to substation equipment image segmentation.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Registration method for power equipment infrared and visible images based on contour feature
    Jiang Q.
    Liu Y.
    Fang J.
    Yan Y.
    Jiang X.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (11): : 252 - 260
  • [22] 3-D Reconstruction for Thermal Infrared Images of Substation Equipment Based on Visual SLAM and Cascade MVSNet
    Tan, Yu-Xuan
    Fan, Shao-Sheng
    Zeng, Xu-Dong
    Wang, Ru-Xin
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 11693 - 11704
  • [23] Multilevel Threshold Segmentation Method for Infrared Image of Power Equipment with Two-dimensional Entropy Based on Bat Algorithm
    Li, Xin
    Cui, Haoyang
    Qin, Lunming
    Li, Gaofang
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON MECHATRONICS, MATERIALS, CHEMISTRY AND COMPUTER ENGINEERING (ICMMCCE 2017), 2017, 141 : 640 - 646
  • [24] Infrared Image Change Detection of Substation Equipment in Power System Using Random Forest
    Yang, Hua
    Gao, Jipu
    Xu, Changbao
    Long, Zheng
    Feng, Weigang
    Xiong, Shaohua
    Liu, Shuaiwei
    Tan, Shan
    2017 13TH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY (ICNC-FSKD), 2017,
  • [25] Infrared Image Enhancement and Segmentation for Extracting the Thermal Anomalies in Electrical Equipment
    Jadin, M. S.
    Taib, S.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2012, 120 (04) : 107 - 112
  • [26] Self-adjusting Residual Network Diagnosis Model for Substation Equipment Thermal Defects Based on Infrared Image
    Wang Y.
    Li H.
    Liang X.
    Li Y.
    Wei C.
    Lu Y.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (09): : 3000 - 3007
  • [27] Research on Construction of Infrared Image Classification Model of Substation Equipment Based on CNN
    Zhou, Kehui
    Liao, Zhiwei
    Zang, Xiaochun
    PROCEEDINGS OF 2019 INTERNATIONAL FORUM ON SMART GRID PROTECTION AND CONTROL (PURPLE MOUNTAIN FORUM), VOL II, 2020, 585 : 1017 - 1028
  • [28] Research on Algorithm for Improving Infrared Image Defect Segmentation of Power Equipment
    Zhang, Jingwen
    Zhu, Wu
    ELECTRONICS, 2023, 12 (07)
  • [29] Robot Box Depalletizing Method Based on Image Instance Segmentation
    Wencai, Z.O.U.
    Baolin, L.I.U.
    Computer Engineering and Applications, 60 (10): : 209 - 216
  • [30] Segmentation of electric equipment infrared image based on CA and OTSU
    Men, Hong
    Yu, Jiaxue
    Qin, Lei
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2011, 31 (09): : 92 - 95