Role of conventional ultrasound and shear wave elastography of median nerve in diagnosis and differentiation of carpal tunnel syndrome severity in correlation with electrodiagnostic studies

被引:0
|
作者
El-Shewi, Islam El-Hefnawi [1 ]
Tawfeek, Aliaa Ali [2 ]
Mohamed, Alaa Abdelhakam [1 ]
Mostafa, Maged Abdulrahman [1 ]
机构
[1] Cairo Univ, Fac Med, Radiol Dept, Giza, Egypt
[2] Cairo Univ, Fac Med, Clin Neurophysiol Dept, Giza, Egypt
来源
关键词
Ultrasound; Shear wave elastography; Carpal tunnel syndrome; Nerve conduction studies;
D O I
10.1186/s43055-024-01215-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe gold standard for CTS diagnosis is abnormalities on electrophysiologic testing in conjunction with specified symptoms. Electrophysiologic testing can also identify the severity of nerve injury.Aim of workAimed to investigate how effective various ultrasonography and elastography parameters at diagnosing and grading the severity of carpal tunnel syndrome in correlation with the electrophysiological evaluation of the median nerve.MethodsThe study included 62 wrists, 31 CTS cases and 25 females. Thirty-one healthy adults served as control group. Eleven males (35.5%) and 20 females (64.5%) were included. All US examinations were done with the subjects sitting with their upper limbs relaxed on a pillow with forearm in supine position, and the fingers are semi-flexed. Ultrasound and elastography parameters were recorded. NCS was done by recording median nerve motor and sensory functions and then comparing median nerve versus radial and ulnar nerves if the previous recordings were normal to detect early starting cases.ResultsUS and elastography can significantly diagnose CTS and detecting its severity (mild/moderate versus severe CTS).ConclusionsIt is noninvasive to examine the median nerve using ultrasound and shear wave elastography, highly sensitive diagnostic modality. It can significantly diagnose CTS and severity of CTS (in contrast to mild, moderate, and severe instances). Mixing high-resolution conventional B-mode US with shear wave ultrasound elastography of the median nerve may increase the diagnostic precision of CTS.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Superb Microvascular Imaging of the Median Nerve in Carpal Tunnel Syndrome: An Electrodiagnostic and Ultrasonographic Study
    Karahan, Ali Yavuz
    Arslan, Serdar
    Ordahan, Banu
    Bakdik, Suleyman
    Ekiz, Timur
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (12) : 2855 - 2861
  • [42] The relationship between ultrasound and electrodiagnostic findings in relation of the severity of carpal tunnel syndrome
    Seyed Mansoor Rayegani
    Rashin Malekmahmoodi
    Kianmehr Aalipour
    Farshad Nouri
    BMC Musculoskeletal Disorders, 25 (1)
  • [43] The relationship of median nerve F-wave parameters with severity and subtypes of carpal tunnel syndrome
    Aygul, Recep
    Kotan, Dilcan
    Ulvi, Hizir
    Kuyucu, Mutlu
    Ozdemir, Gokhan
    Ertekin, Ayfer
    Odabas, Faruk Omer
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2014, 27 (01) : 1 - 6
  • [44] Correlation between median nerve conduction studies and ultrasonography in cases of carpal tunnel syndrome
    El-Habashy, Hala R.
    El-Hadidy, Reem A.
    Ahmed, Sandra M.
    El Sayed, Basma B.
    Ahmed, Aya S.
    EGYPTIAN JOURNAL OF NEUROLOGY PSYCHIATRY AND NEUROSURGERY, 2016, 53 (04): : 206 - 210
  • [45] Role of High Frequency Ultrasound in Diagnosing Carpal Tunnel Syndrome as Compared with Conventional Nerve Conduction Studies
    Singla, Monika
    Sharma, Mukesh K.
    Khurana, Dheraj
    Lal, Vivek
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2020, 23 (05) : 649 - 655
  • [46] Correlation between electrodiagnostic severity and Boston carpal tunnel questionnaire in surgically treated carpal tunnel syndrome patients
    Koo, Jung Hoi
    Bae, Joo-Yul
    Lee, Kiwon
    Park, Ha Sung
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2023, 57 (06) : 357 - 360
  • [47] THE ACCURACY OF PREOPERATIVE ELECTRODIAGNOSTIC STUDIES WHEN COMPARED WITH INTRAOPERATIVE ASSESSMENT OF THE MEDIAN NERVE IN CARPAL-TUNNEL SYNDROME
    KALLINS, MS
    MERIWETHER, MW
    TERWILLIGER, D
    LEWIS, JA
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1987, 68 (09): : 600 - 600
  • [48] CORRELATION BETWEEN ULTRASOUND MEASURES OF THE MEDIAN NERVE AND ELECTRODIAGNOSTIC SEVERITY OF MEDIAN MONONEUROPATHY SEPARATED BY GENDER
    Sanford, Timothy
    Hill, James
    Harris, Matthew
    Cockman, Mitchell
    Howard, James
    MUSCLE & NERVE, 2015, 52 : S13 - S13
  • [49] Sonographic Measurement of Cross-Sectional Area of the Median Nerve in the Diagnosis of Carpal Tunnel Syndrome: Correlation With Nerve Conduction Studies
    Pazzaglia, C.
    Padua, L.
    JOURNAL OF CLINICAL ULTRASOUND, 2010, 38 (03) : 145 - 146
  • [50] Sonographic Measurement of Cross-Sectional Area of the Median Nerve in the Diagnosis of Carpal Tunnel Syndrome: Correlation with Nerve Conduction Studies
    Moran, Luz
    Perez, Maria
    Esteban, Angel
    Bellon, Jose
    Arranz, Beatriz
    del Cerro, Miguel
    JOURNAL OF CLINICAL ULTRASOUND, 2009, 37 (03) : 125 - 131