Role of conventional ultrasound and shear wave elastography of median nerve in diagnosis and differentiation of carpal tunnel syndrome severity in correlation with electrodiagnostic studies

被引:0
|
作者
El-Shewi, Islam El-Hefnawi [1 ]
Tawfeek, Aliaa Ali [2 ]
Mohamed, Alaa Abdelhakam [1 ]
Mostafa, Maged Abdulrahman [1 ]
机构
[1] Cairo Univ, Fac Med, Radiol Dept, Giza, Egypt
[2] Cairo Univ, Fac Med, Clin Neurophysiol Dept, Giza, Egypt
来源
关键词
Ultrasound; Shear wave elastography; Carpal tunnel syndrome; Nerve conduction studies;
D O I
10.1186/s43055-024-01215-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe gold standard for CTS diagnosis is abnormalities on electrophysiologic testing in conjunction with specified symptoms. Electrophysiologic testing can also identify the severity of nerve injury.Aim of workAimed to investigate how effective various ultrasonography and elastography parameters at diagnosing and grading the severity of carpal tunnel syndrome in correlation with the electrophysiological evaluation of the median nerve.MethodsThe study included 62 wrists, 31 CTS cases and 25 females. Thirty-one healthy adults served as control group. Eleven males (35.5%) and 20 females (64.5%) were included. All US examinations were done with the subjects sitting with their upper limbs relaxed on a pillow with forearm in supine position, and the fingers are semi-flexed. Ultrasound and elastography parameters were recorded. NCS was done by recording median nerve motor and sensory functions and then comparing median nerve versus radial and ulnar nerves if the previous recordings were normal to detect early starting cases.ResultsUS and elastography can significantly diagnose CTS and detecting its severity (mild/moderate versus severe CTS).ConclusionsIt is noninvasive to examine the median nerve using ultrasound and shear wave elastography, highly sensitive diagnostic modality. It can significantly diagnose CTS and severity of CTS (in contrast to mild, moderate, and severe instances). Mixing high-resolution conventional B-mode US with shear wave ultrasound elastography of the median nerve may increase the diagnostic precision of CTS.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Role of conventional ultrasound and shear wave elastography of median nerve in diagnosis and differentiation of carpal tunnel syndrome severity in correlation with electrodiagnostic studies
    Islam El-Hefnawi El-Shewi
    Aliaa Ali Tawfeek
    Alaa Abdelhakam Mohamed
    Maged Abdulrahman Mostafa
    Egyptian Journal of Radiology and Nuclear Medicine, 55
  • [2] Diagnostic value of median nerve shear wave ultrasound elastography in diagnosis and differentiation of carpal tunnel syndrome severity
    Heba Refaat Ibrahim
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [3] Diagnostic value of median nerve shear wave ultrasound elastography in diagnosis and differentiation of carpal tunnel syndrome severity
    Ibrahim, Heba Refaat
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [4] Median Nerve Shear Wave Elastography is Associated With the Neurophysiological Severity of Carpal Tunnel Syndrome
    Martikkala, Lauri
    Pemmari, Antti
    Himanen, Sari-Leena
    Maekelae, Katri
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (07) : 1253 - 1263
  • [5] Ultrasound of Median Nerve in the Diagnosis of Carpal Tunnel Syndrome-Correlation with Electrophysiological Studies
    Kanagasabai, K.
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2022, 32 (01): : 16 - 29
  • [6] Wrist to forearm ratio as a median nerve shear wave elastography test in carpal tunnel syndrome diagnosis
    Paluch, Lukasz
    Pietruski, Piotr
    Walecki, Jerzy
    Noszczyk, Bartlomiej Henryk
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2018, 71 (08): : 1146 - 1147
  • [7] Median nerve ultrasound in carpal tunnel syndrome with normal electrodiagnostic tests
    Semra Aktürk
    Raikan Büyükavcı
    Yüksel Ersoy
    Acta Neurologica Belgica, 2020, 120 : 43 - 47
  • [8] Diagnostic potential of ultrasound in carpal tunnel syndrome with different etiologies: correlation of sonographic median nerve measures with electrodiagnostic severity
    Elnady, Basant
    Rageh, Elsayed M.
    Ekhouly, Tohamy
    Fathy, Sabry M.
    Alshaar, Mohamed
    Fouda, El Saeed
    Attar, Mohammed
    Abdelaal, Ahmed M.
    El Tantawi, Ahmed
    Algethami, Mohammed M.
    Bong, David
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [9] Median nerve ultrasound in carpal tunnel syndrome with normal electrodiagnostic tests
    Akturk, Semra
    Buyukavci, Raikan
    Ersoy, Yuksel
    ACTA NEUROLOGICA BELGICA, 2020, 120 (01) : 43 - 47
  • [10] Diagnostic potential of ultrasound in carpal tunnel syndrome with different etiologies: correlation of sonographic median nerve measures with electrodiagnostic severity
    Basant Elnady
    Elsayed M. Rageh
    Tohamy Ekhouly
    Sabry M. Fathy
    Mohamed Alshaar
    El Saeed Fouda
    Mohammed Attar
    Ahmed M. Abdelaal
    Ahmed El Tantawi
    Mohammed M. Algethami
    David Bong
    BMC Musculoskeletal Disorders, 20