Feasibility study of cryoballoon ablation for atrial fibrillation with KODEX-EPD: a single center experience

被引:1
|
作者
Wubulikasimu, Subinuer [1 ,2 ]
Wang, Liang [1 ,2 ]
Yang, Suxia [1 ,2 ]
Sang, Wanyue [1 ,2 ]
Han, Yafan [1 ,2 ]
Wang, Lu [1 ,2 ]
Wang, Feifei [1 ,2 ]
Zhou, Xianhui [1 ,2 ]
Zhang, Jianghua [1 ,2 ]
Xing, Qiang [1 ,2 ]
Tuerhong, Zukela [1 ,2 ]
Xiaokereti, Jiasuoer [1 ,2 ]
Guo, Yankai [1 ,2 ]
Tang, Baopeng [1 ,2 ]
Li, Yaodong [1 ,2 ]
机构
[1] Xinjiang Med Univ, Affiliated Hosp 1, Urumqi, Peoples R China
[2] Dept Cardiac Electrophysiol & Remodeling, Dept Pacing & Electrophysiol, Urumqi, Peoples R China
关键词
SYSTEM;
D O I
10.1038/s41598-023-49475-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To evaluate the feasibility of cryoballoon (CB) ablation of atrial fibrillation (AF) under the guidance of a new three-dimensional (3D) mapping system KODEX-EPD. 40 patients scheduled for CB ablation of AF in the first affiliated Hospital of Xinjiang Medical University from August 2021 to July 2022 were randomly divided into two groups: KODEX-EPD 3D mapping system guidance group (KODEX group, n = 20) and conventional two-dimensional perspective group (standard group, n = 20). The ablation time, operation time, fluoroscopy time, fluoroscopy dose, contrast agent dosage and follow-up data were compared between the two groups. Besides, the feasibility and accuracy of the dielectric sensing system in evaluating pulmonary vein (PV) occlusion in patients with AF during CB ablation were verified. All pulmonary veins were being isolated. The ablation time (36.40 +/- 6.72 min vs 35.15 +/- 6.29 min, P > 0.05) and the operation time (64.20 +/- 11.82 min vs 66.00 +/- 13.18 min, P > 0.05) were not statistically different in the two groups. The standard group has longer fluoroscopy time, dose and contrast medium dosage. There were significant differences in fluoroscopy time (532.30 +/- 72.83 s vs 676.25 +/- 269.33 s, P < 0.05), fluoroscopy dose (110.00 +/- 28.64 mGy vs 144.68 +/- 66.66 mGy, P < 0.05), and contrast medium dosage (71.90 +/- 5.97 ml vs 76.05 +/- 5.93 ml, P < 0.05) between the two groups. The learning curves of the first 5 patients and the last 15 patients in the KODEX group were compared. There was no statistical difference in the ablation time (36.80 +/- 8.56 min vs 36.27 +/- 6.34 min, P > 0.05) or the operation time (69.00 +/- 5.00 min vs 62.60 +/- 13.10 min, P > 0.05); however, compared to the first 5 patients, fluoroscopy time (587.40 +/- 38.34 s vs 513.93 +/- 73.02 s, P < 0.05), fluoroscopy dose (147.85 +/- 35.19 mGy vs 97.39 +/- 8.80 mGy, P < 0.05) and contrast medium dosage (79.60 +/- 1.14 ml vs 69.33 +/- 4.45 ml, P < 0.05) were significantly decreased. Using pulmonary venography as the gold standard, the sensitivity, specificity of the completely occlusion in KODEX group was 93.6% (95% CI 85-97.6%) and 69.6% (95% CI 54-81.8%); and the sensitivity, specificity of the small leak in KODEX group was 93.1% (95% CI 82.4-97.8%) and 82.0% (95% CI 65.9-91.9%). During an average follow-up of (9.90 +/- 1.06) months, there was no statistical difference in arrhythmia recurrence and antiarrhythmic drugs taking after CB ablation between the two groups (P > 0.05). Using the KODEX-EPD system, the CB ablation procedure can correctly evaluate the PV occlusion, and significantly reduce fluoroscopy exposure and contrast medium without significantly increasing the operation time.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Feasibility and efficacy of a novel size adjustable cryoballoon for ablation of atrial fibrillation
    Gerrit Frommeyer
    Christian Ellermann
    Julian Wolfes
    Philipp S. Lange
    Fatih Güner
    Lars Eckardt
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 253 - 255
  • [22] Feasibility and efficacy of a novel size adjustable cryoballoon for ablation of atrial fibrillation
    Frommeyer, Gerrit
    Ellermann, Christian
    Wolfes, Julian
    Lange, Philipp S.
    Guener, Fatih
    Eckardt, Lars
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (02) : 253 - 255
  • [23] Outcomes of Hybrid Endocardial Radiofrequency and Cryoballoon Ablation for Atrial Fibrillation: A Single-center Analysis
    Christian-Miller, Nathaniel
    Wu, Perry
    Williamson, Catherine
    Nakhla, Morcos
    Hayase, Justin
    Benharash, Peyman
    Buch, Eric
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (03) : 792 - 792
  • [24] Patterns of posterior wall isolation using the second-generation cryoballoon for atrial fibrillation ablation: A single-center experience
    Casale, Joel A.
    Kittel, Tyler
    Vivas, Yoel
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1748 - 1748
  • [25] Cryoballoon ablation as index procedure for paroxysmal atrial fibrillation: long-term results from a single center early experience
    Rao, Jayakeerthi Yoganarasimha
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    Casado-Arroyo, Ruben
    Overeinder, Ingrid
    Sarkozy, Andrea
    Paparella, Gaetano
    Capulzini, Lucio
    Sorgente, Antonio
    Rodriguez-Manero, Moises
    Ricciardi, Danilo
    Namdar, Mehdi
    Brugada, Pedro
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2014, 15 (03) : 194 - 198
  • [26] Cryoballoon Ablation of Atrial Fibrillation in Octogenarians
    Akhtar, Tauseef
    Berger, Ronald
    Marine, Joseph E.
    Daimee, Usama A.
    Calkins, Hugh
    Spragg, David
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2020, 9 (02) : 104 - 107
  • [27] Cryoballoon Ablation of Atrial Fibrillation in Octogenarian
    Bai, Rong
    Montoya, Alexis
    Liao, Yu
    Truc Vy Lam
    Lockhart, Carla
    Dai, Yi
    Katrapati, Praneeth
    Martinez, Jake
    Stempihar, Jaime
    Rodriguez, Joy
    Jones, Camelle
    Paveglio, Katie
    Zawaneh, Michael
    CIRCULATION, 2023, 148
  • [28] Robotic Navigation for Ablation of Atrial Fibrillation: Largest Single Center Experience
    Gallinghouse, G. Joseph
    Horton, Rodney P.
    Zagrodzky, Jason D.
    Bailey, Shane M.
    Sanchez, Javier E.
    Canby, Robert C.
    Price, Larry
    Dare, Matthew L.
    Natale, Andrea
    CIRCULATION, 2008, 118 (18) : S925 - S925
  • [29] CRYOBALLOON ABLATION FOR PAROXYSMAL ATRIAL FIBRILLATION
    Guitang, Y.
    Ming, L.
    Zulu, W.
    Yan-chun, L.
    Zhi-qing, J.
    Mingying, D.
    Ya-ling, H.
    HEART, 2015, 101 : A7 - A7
  • [30] Cryoballoon or Radiofrequency Ablation for Atrial Fibrillation
    Providencia, Rui
    Lambiase, Pier D.
    Marijon, Eloi
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (11): : 1099 - 1099