Feasibility study of cryoballoon ablation for atrial fibrillation with KODEX-EPD: a single center experience

被引:1
|
作者
Wubulikasimu, Subinuer [1 ,2 ]
Wang, Liang [1 ,2 ]
Yang, Suxia [1 ,2 ]
Sang, Wanyue [1 ,2 ]
Han, Yafan [1 ,2 ]
Wang, Lu [1 ,2 ]
Wang, Feifei [1 ,2 ]
Zhou, Xianhui [1 ,2 ]
Zhang, Jianghua [1 ,2 ]
Xing, Qiang [1 ,2 ]
Tuerhong, Zukela [1 ,2 ]
Xiaokereti, Jiasuoer [1 ,2 ]
Guo, Yankai [1 ,2 ]
Tang, Baopeng [1 ,2 ]
Li, Yaodong [1 ,2 ]
机构
[1] Xinjiang Med Univ, Affiliated Hosp 1, Urumqi, Peoples R China
[2] Dept Cardiac Electrophysiol & Remodeling, Dept Pacing & Electrophysiol, Urumqi, Peoples R China
关键词
SYSTEM;
D O I
10.1038/s41598-023-49475-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To evaluate the feasibility of cryoballoon (CB) ablation of atrial fibrillation (AF) under the guidance of a new three-dimensional (3D) mapping system KODEX-EPD. 40 patients scheduled for CB ablation of AF in the first affiliated Hospital of Xinjiang Medical University from August 2021 to July 2022 were randomly divided into two groups: KODEX-EPD 3D mapping system guidance group (KODEX group, n = 20) and conventional two-dimensional perspective group (standard group, n = 20). The ablation time, operation time, fluoroscopy time, fluoroscopy dose, contrast agent dosage and follow-up data were compared between the two groups. Besides, the feasibility and accuracy of the dielectric sensing system in evaluating pulmonary vein (PV) occlusion in patients with AF during CB ablation were verified. All pulmonary veins were being isolated. The ablation time (36.40 +/- 6.72 min vs 35.15 +/- 6.29 min, P > 0.05) and the operation time (64.20 +/- 11.82 min vs 66.00 +/- 13.18 min, P > 0.05) were not statistically different in the two groups. The standard group has longer fluoroscopy time, dose and contrast medium dosage. There were significant differences in fluoroscopy time (532.30 +/- 72.83 s vs 676.25 +/- 269.33 s, P < 0.05), fluoroscopy dose (110.00 +/- 28.64 mGy vs 144.68 +/- 66.66 mGy, P < 0.05), and contrast medium dosage (71.90 +/- 5.97 ml vs 76.05 +/- 5.93 ml, P < 0.05) between the two groups. The learning curves of the first 5 patients and the last 15 patients in the KODEX group were compared. There was no statistical difference in the ablation time (36.80 +/- 8.56 min vs 36.27 +/- 6.34 min, P > 0.05) or the operation time (69.00 +/- 5.00 min vs 62.60 +/- 13.10 min, P > 0.05); however, compared to the first 5 patients, fluoroscopy time (587.40 +/- 38.34 s vs 513.93 +/- 73.02 s, P < 0.05), fluoroscopy dose (147.85 +/- 35.19 mGy vs 97.39 +/- 8.80 mGy, P < 0.05) and contrast medium dosage (79.60 +/- 1.14 ml vs 69.33 +/- 4.45 ml, P < 0.05) were significantly decreased. Using pulmonary venography as the gold standard, the sensitivity, specificity of the completely occlusion in KODEX group was 93.6% (95% CI 85-97.6%) and 69.6% (95% CI 54-81.8%); and the sensitivity, specificity of the small leak in KODEX group was 93.1% (95% CI 82.4-97.8%) and 82.0% (95% CI 65.9-91.9%). During an average follow-up of (9.90 +/- 1.06) months, there was no statistical difference in arrhythmia recurrence and antiarrhythmic drugs taking after CB ablation between the two groups (P > 0.05). Using the KODEX-EPD system, the CB ablation procedure can correctly evaluate the PV occlusion, and significantly reduce fluoroscopy exposure and contrast medium without significantly increasing the operation time.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Feasibility study of cryoballoon ablation for atrial fibrillation with KODEX-EPD: a single center experience
    Subinuer Wubulikasimu
    Liang Wang
    Suxia Yang
    Wanyue Sang
    Yafan Han
    Lu Wang
    Feifei Wang
    Xianhui Zhou
    Jianghua Zhang
    Qiang Xing
    Zukela Tuerhong
    Jiasuoer Xiaokereti
    Yankai Guo
    Baopeng Tang
    Yaodong Li
    Scientific Reports, 13
  • [2] Feasibility and efficacy using the KODEX-EPD imaging system in right atrial flutter ablation: a single center experience
    Schillaci, V.
    Stabile, G.
    Shopova, G.
    Arestia, A.
    Agresta, A.
    Salito, A.
    Solimene, F.
    EUROPEAN HEART JOURNAL, 2021, 42 : 383 - 383
  • [3] Near zero fluoroscopy in cryoballoon catheter ablation in patients with atrial fibrillation using the new KODEX-EPD imaging system
    Schillaci, Vincenzo
    Arestia, Alberto
    Shopova, Gergana
    Stabile, Giuseppe
    Solimene, Francesco
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (05) : 1479 - 1479
  • [4] Cryoablation Utilizing the KODEX-EPD Mapping System Versus Conventional Cryoballoon Ablation in the Management of Patients With Atrial Fibrillation: A Literature Review and MetaAnalysis
    Meretsky, Christopher R.
    Patel, Vaishvik K.
    Mahmoodi, Arshia
    Schiuma, Anthony T.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [5] Potential advantages of the KODEX-EPD system as the fourth 3D mapping system for atrial fibrillation ablation
    Yoshida, Kentaro
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (04) : 626 - 628
  • [6] Cryoballoon ablation for persistent atrial fibrillation - Large single-center experience
    Straube, Florian
    Hartl, Stefan
    Dorwarth, Uwe
    Wankerl, Michael
    Bunz, Benedikt
    Ebersberger, Ullrich
    Hoffmann, Ellen
    JOURNAL OF CARDIOLOGY, 2016, 68 (5-6) : 492 - 497
  • [7] First clinical experience with KODEX-EPD: a novel dielectric imaging and navigation system for catheter ablation
    Abeln, B. G. S.
    Simmers, T. A.
    Maarse, M.
    Van Dijk, V. F.
    Wijffels, M. C. E. F.
    Balt, J. C.
    Boersma, L. V. A.
    Dekker, L. R. C.
    EUROPEAN HEART JOURNAL, 2020, 41 : 428 - 428
  • [9] Cryoballoon atrial fibrillation ablation experience in Japan
    Miyazaki, Shinsuke
    CURRENT OPINION IN CARDIOLOGY, 2022, 37 (01) : 68 - 73
  • [10] A long-term evaluation of cryoballoon ablation in 205 atrial fibrillation patients: a single center experience
    Boho, Alexander
    Misikova, Silvia
    Spurny, Peter
    Komanova, Erika
    Kerekanic, Michal
    Hudak, Marek
    Stancak, Branislav
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (19-20) : 779 - 785