Analysis of shift in discharge coefficient for contaminated multihole orifice flow meter

被引:2
|
作者
Almutairi, Jaber Hmoud [1 ]
Hasecic, Amra [2 ]
Bikic, Sinisa [3 ]
Dzaferovic, Ejub [2 ]
机构
[1] Publ Author Appl Educ & Training, Coll Technol Studies, Shuwaikh 70654, Kuwait
[2] Univ Sarajevo, Fac Mech Engn, Sarajevo 71000, Bosnia & Herceg
[3] Univ Novi Sad, Fac Tech Sci, Novi Sad 21000, Serbia
关键词
Multi-hole orifice flow meter; Discharge coefficient; Contamination; Computational fluid dynamic; COMPACT INSTALLATIONS; PRESSURE LOSS; PLATE;
D O I
10.1016/j.flowmeasinst.2023.102443
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The aim of this paper is to provide a comprehensive numerical study of influence of contamination and multihole orifice (MHO) flow meter geometry on shift in discharge coefficient. In this research, authors analyzed steady, three-dimensional, turbulent flow of dry air through MHO flow meter with 3 different beta parameters. Shift in discharge coefficient was calculated for 29 different combinations of contamination parameters for 7 contamination angles, 3 different Reynolds numbers and 3 beta parameters. Numerical method that was used was finite volume method with SIMPLE algorithm and standard k-epsilon turbulence model. Grid sensitivity study was performed on four systematically refined numerical grids for MHO with contamination for all values of Reynolds number, all values of beta parameters and 3 values of contamination angle. Obtained results were grid independent. Numerical results for MHO without contamination were compared with the experimental results found in the literature. It was found that contamination angle has most influence on shift in discharge coefficient. Also it was found that the contamination has influence on the change of pressure drop values, which directly affects the change of other parameters. Pressure drop and singular pressure loss coefficient of the orifice with contamination are smaller compared to the values for a pure orifice, whereby the measurement accuracy was reduced. It was found that the multi-hole orifice meter was less sensitive to the pressure drop changes due to the increasing of contamination angle in regards to the single-hole orifice meters.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Orifice plate meter wet gas flow performance
    Steven, Richard
    Hall, Andrew
    FLOW MEASUREMENT AND INSTRUMENTATION, 2009, 20 (4-5) : 141 - 151
  • [32] Prediction and parameter quantitative analysis of side orifice discharge coefficient based on machine learning
    Shen, Guiying
    Li, Shanshan
    Parsaie, Abbas
    Li, Guodong
    Cao, Dingye
    Pandey, Prashant
    WATER SUPPLY, 2022, 22 (12) : 8880 - 8892
  • [33] Simulation of the flow field of multi-hole orifice flow meter
    Yu, Hongshi
    Zhang, Tao
    Zhao, Shanshan
    Jiang, Wei
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2014, 47 (01): : 61 - 66
  • [34] CLARIFICATION OF MEASUREMENT ERROR OF ORIFICE FLOW METER IN WET STEAM FLOW
    Morita, Ryo
    Umezawa, Shuichi
    Funaki, Tatsuya
    Inada, Fumio
    Sakai, Masayuki
    Ishibashi, Masahiro
    Uchiyama, Yuta
    Amari, Haruo
    Takamoto, Masaki
    Shimada, Hiroyuki
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 2, 2012, : 307 - +
  • [35] COMPUTATIONAL MODELING OF FLOW RATE MEASUREMENTS USING AN ORIFICE FLOW METER
    Xu, YiQin
    Coxe, Daniel
    Peet, Yulia
    Lee, Taewoo
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2018, VOL 2, 2018,
  • [36] Correcting the error of a flow meter by blunting the edge of the orifice plate
    Novitskii, PV
    MEASUREMENT TECHNIQUES, 1996, 39 (11) : 1115 - 1118
  • [38] Response of a slotted orifice flow meter to an air/water mixture
    Morrison, GL
    Terracina, D
    Brewer, C
    Hall, KR
    FLOW MEASUREMENT AND INSTRUMENTATION, 2001, 12 (03) : 175 - 180
  • [39] WATER FLOW METER USING NEW ORIFICE PLATE ARRANGEMENT
    Benaissa T.
    Ali N.
    International Journal of Fluid Mechanics Research, 2022, 49 (06) : 35 - 45
  • [40] Numerical simulations for multi-hole orifice flow meter
    Singh, V. K.
    Tharakan, T. John
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 45 : 375 - 383