Experimental investigation on battery thermal management with ultra-thin vapor chamber

被引:4
|
作者
Yi, Feng [1 ]
Gan, Yunhua [1 ,2 ]
Li, Rui [1 ]
机构
[1] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Peoples R China
[2] South China Univ Technol, Sch Elect Power Engn, Wushan Rd, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
Battery thermal management system; Ultra -thin vapor chamber; Liquid cooling; Heat dissipation; Lithium -ion battery; LITHIUM-ION BATTERY; PERFORMANCE; SYSTEM; PARAMETERS;
D O I
10.1016/j.applthermaleng.2024.122668
中图分类号
O414.1 [热力学];
学科分类号
摘要
In electric vehicles, the chemical reactions occurring within the battery necessitate an efficient thermal management system to keep the battery within its optimal temperature range. Therefore, the development of a compact and effective thermal management system is essential. In this paper, a novel battery thermal management system based on ultra-thin vapor chambers with a thickness of 1 mm is proposed. To analyze the key parameters that affect the thermal performance of the battery thermal management system, an experimental system was established to investigate coolant flow rate, inlet coolant temperature, filling rate, and gravity conditions. Orthogonal design and fuzzy grey relational analysis were employed as evaluation methods. Orthogonal experiments can obtain a balanced sample of high precision with fewer trial runs, while fuzzy grey relational analysis is based on the measurement of similarity or dissimilarity between data sequences to explore the relationships among key system factors. The results show that the implemented battery management system achieves a reduction in maximum temperature by 23.2 %, 24.4 %, and 25.5 % under discharge rates of 1C, 1.5C, and 2C, respectively, while maintaining a temperature difference of less than 2 degree celsius. Even under conditions of high inlet coolant temperature of 30 degree celsius and a discharge rate of 2C, the temperature difference remained below 2.28 degree celsius. Subsequently, the optimal filling rate is 120 %, and the maximum temperature of the battery pack is minimized with a temperature difference of less than 3 degrees C at this filling rate. Furthermore, considering the sensitivity evaluation, the discharge rate exhibited the most significant impact on both the maximum temperature and temperature difference, followed by the inlet coolant temperature and filling rate.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Experimental research on battery thermal management system based on vapor chamber technology
    Dan D.
    Lian H.
    Zhang Y.
    Yao C.
    Wang Y.
    Ren W.
    Zhuge W.
    Qian Y.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2019, 49 (09): : 1023 - 1030
  • [22] ULTRA-THIN LI BATTERY
    LIU, ZH
    LIU, LM
    ZHANG, WB
    CHINESE SCIENCE BULLETIN, 1992, 37 (17): : 1426 - 1430
  • [23] ULTRA-THIN Li BATTERY
    刘在海
    刘丽敏
    张文彬
    ChineseScienceBulletin, 1992, (17) : 1426 - 1430
  • [24] Numerical investigation of a battery thermal management system integrated with vapor chamber and thermoelectric refrigeration
    Luo, Ding
    Wu, Haifeng
    Cao, Jin
    Yan, Yuying
    Yang, Xuelin
    Cao, Bingyang
    JOURNAL OF CLEANER PRODUCTION, 2024, 434
  • [25] Thermal performance of aluminum vapor chamber for EV battery thermal management
    Kim, Jin Sub
    Shin, Dong Hwan
    You, Seung M.
    Lee, Jungho
    APPLIED THERMAL ENGINEERING, 2021, 185 (185)
  • [26] Design and fabrication of an ultra-thin silicon vapor chamber for compact electronic cooling
    Struss, Quentin
    Coudrain, Perceval
    Colonna, Jean-Philippe
    Souifi, Abdelkader
    Gontrand, Christian
    Deschaseaux, Edouard
    Mauguen, Gaelle
    Mathieu, Vincent
    Magis, Thomas
    Simon, Gilles
    Frechette, Luc G.
    2020 IEEE 70TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2020), 2020, : 2259 - 2265
  • [27] A novel ultra-thin vapor chamber with composite wick for portable electronics cooling
    Yan, Caiman
    Li, Hongming
    Tang, Yong
    Ding, Xinrui
    Yuan, Xuepeng
    Liang, Yifu
    Zhang, Shiwei
    APPLIED THERMAL ENGINEERING, 2023, 226
  • [28] Research and optimization design of limited internal cavity of ultra-thin vapor chamber
    Huang, Guangwen
    Liu, Wangyu
    Luo, Yuanqiang
    Deng, Tao
    Li, Yong
    Chen, Hanyin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [29] Thermal performance of a novel stainless steel ultra-thin vapor chamber fabricated by a low-cost process
    Atta-Ur-Rehman
    Li, Yong
    Ali, Usman
    Zhou, Wenjie
    Guo, Xiaojun
    Tian, Yue
    APPLIED THERMAL ENGINEERING, 2025, 268
  • [30] Thermal resistance optimization of ultra-thin vapor chamber based on data-driven model and metaheuristic algorithm
    Ye, Guimin
    Sheng, Yuxuan
    Zou, Yaping
    Zhang, Yang
    Tong, Wentao
    Yu, Xiao
    Jian, Qifei
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 153