Experimental investigation on battery thermal management with ultra-thin vapor chamber

被引:4
|
作者
Yi, Feng [1 ]
Gan, Yunhua [1 ,2 ]
Li, Rui [1 ]
机构
[1] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Peoples R China
[2] South China Univ Technol, Sch Elect Power Engn, Wushan Rd, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
Battery thermal management system; Ultra -thin vapor chamber; Liquid cooling; Heat dissipation; Lithium -ion battery; LITHIUM-ION BATTERY; PERFORMANCE; SYSTEM; PARAMETERS;
D O I
10.1016/j.applthermaleng.2024.122668
中图分类号
O414.1 [热力学];
学科分类号
摘要
In electric vehicles, the chemical reactions occurring within the battery necessitate an efficient thermal management system to keep the battery within its optimal temperature range. Therefore, the development of a compact and effective thermal management system is essential. In this paper, a novel battery thermal management system based on ultra-thin vapor chambers with a thickness of 1 mm is proposed. To analyze the key parameters that affect the thermal performance of the battery thermal management system, an experimental system was established to investigate coolant flow rate, inlet coolant temperature, filling rate, and gravity conditions. Orthogonal design and fuzzy grey relational analysis were employed as evaluation methods. Orthogonal experiments can obtain a balanced sample of high precision with fewer trial runs, while fuzzy grey relational analysis is based on the measurement of similarity or dissimilarity between data sequences to explore the relationships among key system factors. The results show that the implemented battery management system achieves a reduction in maximum temperature by 23.2 %, 24.4 %, and 25.5 % under discharge rates of 1C, 1.5C, and 2C, respectively, while maintaining a temperature difference of less than 2 degree celsius. Even under conditions of high inlet coolant temperature of 30 degree celsius and a discharge rate of 2C, the temperature difference remained below 2.28 degree celsius. Subsequently, the optimal filling rate is 120 %, and the maximum temperature of the battery pack is minimized with a temperature difference of less than 3 degrees C at this filling rate. Furthermore, considering the sensitivity evaluation, the discharge rate exhibited the most significant impact on both the maximum temperature and temperature difference, followed by the inlet coolant temperature and filling rate.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Experimental Investigation on Ultra-Thin Vapor Chamber with Composite Wick for Electronics Thermal Management
    Zhang, Shiwei
    Huang, Haoyi
    Bai, Jingjing
    Yan, Caiman
    Qiu, Huarong
    Tang, Yong
    Luo, Fangqiong
    MICROMACHINES, 2024, 15 (05)
  • [2] Experimental study on the thermal management performance of battery with ultra-thin vapor chamber under liquid cooling condition
    Li, Rui
    Gan, Yunhua
    Liang, Jialin
    Yi, Feng
    Li, Yong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 240
  • [3] Thermal performance analysis of L-shaped ultra-thin vapor chamber for lithium battery thermal management considering tilt angle and vibration
    Yi, Feng
    Gan, Yunhua
    Li, Rui
    ENERGY, 2025, 320
  • [4] Ultra-thin minichannel LCP for EV battery thermal management
    Jin, L. W.
    Lee, P. S.
    Kong, X. X.
    Fan, Y.
    Chou, S. K.
    APPLIED ENERGY, 2014, 113 : 1786 - 1794
  • [5] Experimental Investigation Of An Ultra-thin Vapor Chamber With Water And Pure 2-propanol As Working Fluids
    Baruah, Arunjoy
    Mathew, John
    Krishnan, Shankar
    2023 29TH INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS, THERMINIC, 2023,
  • [6] Investigation of aqueous alcohol solutions as working fluids in an ultra-thin vapor chamber
    Baruah, Arunjoy
    Mathew, John
    Krishnan, Shankar
    EXPERIMENTAL HEAT TRANSFER, 2024, 37 (07) : 1186 - 1202
  • [7] Experimental Investigation on Cooling/Heating Characteristics of Ultra-Thin Micro Heat Pipe for Electric Vehicle Battery Thermal Management
    Liu, Fei-Fei
    Lan, Feng-Chong
    Chen, Ji-Qing
    Li, Yi-Gang
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2018, 31 (01)
  • [8] A non-contact thermal testing system for ultra-thin vapor chamber
    Jiang, Xinyue
    Chen, Anqi
    Jiang, Fan
    Guo, Wei
    Lv, You
    Sun, Qi
    Cui, Wei
    Lee, Fang-Shou
    Zhu, Yuan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (12):
  • [9] Experimental Investigation on Cooling/Heating Characteristics of Ultra-Thin Micro Heat Pipe for Electric Vehicle Battery Thermal Management
    Fei-Fei Liu
    Feng-Chong Lan
    Ji-Qing Chen
    Yi-Gang Li
    Chinese Journal of Mechanical Engineering, 2018, 31 (03) : 179 - 188
  • [10] Experimental Investigation on Cooling/Heating Characteristics of Ultra-Thin Micro Heat Pipe for Electric Vehicle Battery Thermal Management
    Fei-Fei Liu
    Feng-Chong Lan
    Ji-Qing Chen
    Yi-Gang Li
    Chinese Journal of Mechanical Engineering, 2018, 31