Image reconstruction for the coded aperture system in nuclear safety and security using a Monte Carlo-based system matrix

被引:2
|
作者
Yu, Yue [1 ,2 ]
Sun, Xiaoli [1 ,2 ,3 ]
Zhang, Zhiming [1 ,2 ,3 ]
Liu, Shuangquan [1 ,3 ]
Liang, Xiuzuo [1 ]
Li, Daowu [1 ]
Shuai, Lei [1 ]
Hu, Tingting [1 ,3 ]
Wei, Long [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing 100049, Peoples R China
[3] Jinan Lab Appl Nucl Sci, Jinan 250131, Peoples R China
基金
中国国家自然科学基金;
关键词
Coded aperture; System matrix; Image reconstruction; Low count imaging; Extended sources; GAMMA-CAMERA;
D O I
10.1007/s41605-023-00381-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Purpose Accurate localization of radioactive materials is critical to nuclear safety and nuclear security. A coded aperture imaging system provides a visualization solution. However, the correlation method has poor reconstruction performance for sources with low counts and for extended sources. Methods In this study, a Monte Carlo optimization-based MLEM algorithm (MC-MLEM) is proposed. The system matrix was obtained by accurate Monte Carlo simulation, so the physical effects such as mask penetration that affect the imaging process were taken into account in the MLEM algorithm. In the simulation process, the normalization of the system matrix was realized by controlling the source at different position of the source plane to have the same activity and emission angle. Results The experimental results showed that compared with the correlation method, the MC-MLEM algorithm could improve the signal-to-noise ratio and angular resolution and locate the source position quickly and accurately under low count conditions. Furthermore, the MC-MLEM algorithm could reconstruct the shape of the extended source and the expected activity ratio of cold-hot sources with large activity differences. Conclusion The MC-MLEM algorithm improved the imaging results and enhanced the reconstruction performance.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [31] A GPU-accelerated and Monte Carlo-based intensity modulated proton therapy optimization system
    Ma, Jiasen
    Beltran, Chris
    Tseung, Hok Seum Wan Chan
    Herman, Michael G.
    MEDICAL PHYSICS, 2014, 41 (12)
  • [32] RapidBrachyMCTPS: Addition of Contouring Tools to the Monte Carlo-Based Treatment Planning System for Brachytherapy Applications
    Glickman, Harry
    Antaki, Majd
    Enger, Shirin A.
    MEDICAL PHYSICS, 2019, 46 (06) : E580 - E580
  • [33] Use of a Monte Carlo-based probability matrix for 3-D iterative reconstruction of MADPET-II data
    Rafecas, M
    Mosler, B
    Dietz, M
    Pögl, M
    Stamatakis, A
    McElroy, DP
    Ziegler, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2597 - 2605
  • [34] A GPU-Accelerated and Monte Carlo-Based Intensity Modulated Proton Therapy Optimization System
    Ma, J.
    Tseung, H. Wan Chan
    Beltran, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 535 - 536
  • [35] Toward automatic field selection and planning using Monte Carlo-based direct aperture optimization in modulated electron radiotherapy
    Alexander, Andrew
    DeBlois, Francois
    Seuntjens, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16): : 4563 - 4576
  • [36] Pre-Clinical Assessment of HDR Eye Plaque Treatment Using a Monte Carlo-Based Treatment Planning System
    Nunez, D. Aramburu
    Antaki, M.
    Morcos, M.
    Huang, S.
    Enger, S. Abbasinejad
    Barker, C.
    Damato, A.
    Cohen, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E830 - E831
  • [37] Monte Carlo-based treatment planning for a spoiler system with experimental validation using plane-parallel ionization chambers
    Kang, SK
    Cho, BC
    Park, SH
    Park, HC
    Bae, H
    Kim, JO
    Keall, PJ
    Siebers, JV
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (22): : 5145 - 5155
  • [38] Monte-Carlo based system matrix generation for the Biograph mMR
    Cheng, Xiaoyin
    Delso, Gaspar
    Kraus, Rebekka
    Ziegler, Sibylle
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [39] Reconstruction of compressive spectral imaging system of a FISTA algorithm-based coded aperture
    Sun, N. (sunnian1234@163.com), 1600, Chinese Society of Astronautics (43):
  • [40] Characterizing the ExacTrac Image Guidance System Using Monte Carlo Modelling
    Spurway, Alan
    Darvish-Molla, Sahar
    Sattarivand, Mike
    MEDICAL PHYSICS, 2019, 46 (11) : 5377 - 5377