Analyses of Isokinetic Thigh Muscle Strength: Camera-Based Assessment Alters the Magnitude, but Not the Message

被引:5
|
作者
Alt, Tobias [1 ]
Nolte, Kevin [2 ]
Horn, Dennis [3 ]
Modenbach, Dominik [2 ]
Knicker, Axel J. [3 ,4 ]
Jaitner, Thomas [2 ]
机构
[1] Olymp Training & Testing Ctr Westphalia, Dortmund, Germany
[2] TU Dortmund Univ, Dortmund, Germany
[3] German Sport Univ Cologne, Cologne, Germany
[4] Res Ctr Elite Sports Momentum, Cologne, Germany
关键词
Axis misalignment correction; hamstrings-quadriceps ratio; isokinetic strength tests; kinematics; measuring accuracy; KNEE FLEXION; HIP-FLEXION; JOINT; EXTENSION; RECONSTRUCTION; RESULTANT; FIXATION; MOMENTS; MOTION; RETURN;
D O I
10.1080/02701367.2022.2053648
中图分类号
F [经济];
学科分类号
02 ;
摘要
Background: Thigh muscle strength capacities are major modifiable risk factors for knee and thigh muscle injuries. Therefore, their valid assessment is essential. Most isokinetic knee tests are conducted in a seated position and rely on dynamometer-based data. However, their accuracy is doubtful because axis alignment is erroneous. Purpose: This study investigated if hip angle (flexed vs. extended) and assessment method (dynamometer-based vs. camera-based) affect isokinetic outcome parameters. Methods: Sixteen healthy male participants (27 years, 184 cm, 80 kg) performed discrete isokinetic tests of the knee flexors and extensors (60 degrees/s) while their kinematics were captured (100 fps). Results: Both assessment methods revealed very strong linear relationships (94% <= R-2 <= 98%) although peak moments (d <= 0.87), contractional work (d <= 1.26), and functional knee flexor:extensor ratios (d <= 0.81) significantly differed. Seated knee flexor tests demonstrated the largest knee trajectory center's misalignment (x = 4.0 cm, z = -2.5 cm; 1.37 <= d <= 4.74). Conclusion: Hip-angle induced kinematic changes did not affect the relation between the lever arms, thus causing highly proportional deviations of kinetic parameters. The assessment method altered the magnitude, but not the message of isokinetic knee tests, which should be preferentially performed with extended hip joint to improve axis alignment. Knowledge of these kinetic and kinematic interactions assists practitioners and scientists with isokinetic tests and/or rehabilitation training to ensure reasonable interpretations of gathered isokinetic outcomes.
引用
收藏
页码:783 / 792
页数:10
相关论文
共 50 条
  • [21] Early ACL reconstruction shows an improved recovery of isokinetic thigh muscle strength compared to delayed or chronic cases
    Wenning, Markus
    Mauch, Marlene
    Heitner, Albrecht H.
    Bode, Gerrit
    Sofack, Ghislain
    Ritzmann, Ramona
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) : 5741 - 5750
  • [22] Camera-based system for quality assessment of fresh beef based on image analysis
    Pereira, Leandro Martins
    Lins, Romulo Gonsalves
    Gaspar, Ricardo
    MEASUREMENT: FOOD, 2022, 5
  • [23] Design and validation of depth camera-based static posture assessment system
    Xing, Qingjun
    Hong, Ruiwei
    Shen, Yuanyuan
    Shen, Yanfei
    ISCIENCE, 2023, 26 (10)
  • [24] A Digital Camera-Based Eye Movement Assessment Method for NeuroEye Examination
    Hassan, Mohamed Abul
    Yin, Xuwang
    Zhuang, Yan
    Aldridge, Chad M.
    Mcmurry, Timothy
    Southerland, Andrew M.
    Rohde, Gustavo K.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (02) : 655 - 665
  • [25] A camera-based attention level assessment tool designed for classroom usage
    Chun-Hsiung Tseng
    Yung-Hui Chen
    The Journal of Supercomputing, 2018, 74 : 5889 - 5902
  • [26] Isokinetic assessment of hip muscle concentric strength in normal subjects: A reproducibility study
    Dugailly, PM
    Brassinne, E
    Pirotte, E
    Mouraux, D
    Feipel, V
    Klein, P
    ISOKINETICS AND EXERCISE SCIENCE, 2005, 13 (02) : 129 - 137
  • [27] Muscle strength particularity of Grand Tour cyclists from knee isokinetic assessment
    Dauty, M.
    Menu, P.
    Mesland, O.
    Fouasson-Chailloux, A.
    SCIENCE & SPORTS, 2020, 35 (02) : 82 - 90
  • [28] A wearable smartphone-enabled camera-based system for gait assessment
    Kim, Albert
    Kim, Junyoung
    Rietdyk, Shirley
    Ziaie, Babak
    GAIT & POSTURE, 2015, 42 (02) : 138 - 144
  • [29] A camera-based attention level assessment tool designed for classroom usage
    Tseng, Chun-Hsiung
    Chen, Yung-Hui
    JOURNAL OF SUPERCOMPUTING, 2018, 74 (11): : 5889 - 5902
  • [30] Depth Camera-based Monitoring and Simulation System for Weight Training Assessment
    Qu, Zijia
    Chan, Colin Pak Yu
    Liu, Yanchen
    Xue, Jiaqi
    Lai, King Wai Chiu
    2024 IEEE INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND ITS SOCIAL IMPACTS, ARSO, 2024, : 173 - 176