Clinical Linear Accelerator-Based Electron FLASH: Pathway for Practical Translation to FLASH Clinical Trials

被引:5
|
作者
No, Hyunsoo Joshua [1 ]
Wu, Yufan [1 ]
Dworkin, Michael Louis [1 ]
Manjappa, Rakesh [1 ]
Skinner, Lawrie [1 ]
Ashraf, M. Ramish [1 ]
Lau, Brianna [1 ]
Melemenidis, Stavros [1 ]
Viswanathan, Vignesh [1 ]
Yu, Amy Shu-Jung [1 ]
Surucu, Murat [1 ]
Schuler, Emil [2 ]
Graves, Edward Elliot [1 ,3 ]
Maxim, Peter Gregor [4 ]
Loo Jr, Billy W. [1 ,3 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
[2] Univ Texas MD Anderson Canc Ctr, Div Radiat Oncol, Dept Radiat Phys, Houston, TX USA
[3] Stanford Univ, Stanford Canc Inst, Sch Med, Stanford, CA 94305 USA
[4] Univ Calif Irvine, Dept Radiat Oncol, Orange, CA USA
基金
美国国家卫生研究院;
关键词
DOSE-RATE; RADIATION DELIVERY; BEAM DOSIMETRY; IRRADIATION; THERAPY; MICE;
D O I
10.1016/j.ijrobp.2023.04.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Ultrahigh-dose-rate (UHDR) radiation therapy (RT) has produced the FLASH effect in preclinical models: reduced toxicity with comparable tumor control compared with conventional-dose-rate RT. Early clinical trials focused on UHDR RT feasibility using specialized devices. We explore the technical feasibility of practical electron UHDR RT on a standard clinical linear accelerator (LINAC).Methods and Materials: We tuned the program board of a decommissioned electron energy for UHDR electron delivery on a clinical LINAC without hardware modification. Pulse delivery was controlled using the respiratory gating interface. A short source-to-surface distance (SSD) electron setup with a standard scattering foil was configured and tested on an anthropomorphic phantom using circular blocks with 3-to 20-cm field sizes. Dosimetry was evaluated using radiochromic film and an ion chamber profiler.Results: UHDR open-field mean dose rates at 100, 80, 70, and 59 cm SSD were 36.82, 59.52, 82.01, and 112.83 Gy/s, respectively. At 80 cm SSD, mean dose rate was similar to 60 Gy/s for all collimated field sizes, with an R80 depth of 6.1 cm corresponding to an energy of 17.5 MeV. Heterogeneity was <5.0% with asymmetry of 2.2% to 6.2%. The short SSD setup was feasible under realistic treatment conditions simulating broad clinical indications on an anthropomorphic phantom.Conclusions: Short SSD and tuning for high electron beam current on a standard clinical LINAC can deliver flat, homogenous UHDR electrons over a broad, clinically relevant range of field sizes and depths with practical working distances in a configuration easily reversible to standard clinical use. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:482 / 492
页数:11
相关论文
共 50 条
  • [21] The Conversion of Clinical Linear Accelerators for FLASH Radiation Delivery
    Newell, Laurence J.
    Bedi, Vikramaditya
    Clayton, James E.
    Hsu, Hsin L. U.
    Pawlak, Daniel
    Senadheera, Lesitha
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 110 (03): : 908 - 909
  • [22] Failure Mode and Effects Analysis for Experimental Use of FLASH on a Clinical Accelerator
    Rahman, Mahbubur
    Zhang, Rongxiao
    Gladstone, David J.
    Williams, Benjamin B.
    Chen, Erli
    Dexter, Chad A.
    Thompson, Lawrence
    Bruza, Petr
    Pogue, Brian W.
    PRACTICAL RADIATION ONCOLOGY, 2023, 13 (02) : 153 - 165
  • [23] CLINICAL-TRIAL OF 19 PITUITARY-ADENOMAS WITH LINEAR ACCELERATOR-BASED STEREOTAXIC RADIOSURGERY
    JANG, H
    YOON, S
    CHUNG, S
    SUH, T
    RYU, M
    SHINN, KS
    RADIOLOGY, 1995, 197 : 264 - 264
  • [24] Dosimetry with a clinical linac adapted to FLASH electron beams
    Szpala, Stanislaw
    Huang, Vicky
    Zhao, Yingli
    Kyle, Alastair
    Minchinton, Andrew
    Karan, Tania
    Kohli, Kirpal
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 50 - 59
  • [25] FLASH Clinical Trials In Regard to Buchsbaum et al Reply
    Deek, Matthew P.
    Stish, Bradley J.
    Tran, Phuoc T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 110 (05): : 1547 - 1548
  • [26] Feasibility of Clinically Practical Ultra-High Dose Rate (FLASH) Radiation Delivery by a Reversible Configuration of a Standard Clinical-Use Linear Accelerator
    No, H. J.
    Wu, Y. F.
    Manjappa, R.
    Skinner, L.
    Lau, B.
    Melemenidis, S.
    Yu, S. J.
    Surucu, M.
    Schueler, E.
    Bush, K.
    Graves, E. E.
    Maxim, P. G.
    Loo, B. W., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : S32 - S32
  • [27] Monte Carlo Based Treatment Planning Workflow for Pre-Clinical and Clinical Electron Flash Studies
    Ashraf, M. R.
    Melemenidis, S.
    Schulz, J. B.
    Loo, B. W., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E96 - E97
  • [28] CLINICAL EXPERIENCES WITH ONBOARD IMAGER KV IMAGES FOR LINEAR ACCELERATOR-BASED STEREOTACTIC RADIOSURGERY AND RADIOTHERAPY SETUP
    Hong, Linda X.
    Chen, Chin C.
    Garg, Madhur
    Yaparpalvi, Ravindra
    Mah, Dennis
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02): : 556 - 561
  • [29] Linear accelerator-based stereotactic radiosurgery of intracranial meningiomas: results of the first 5 years of clinical practice
    Abdelaziz, Osama S.
    Kandil, Alaa
    El-Assaal, Shaaban
    Abdelaziz, Amro
    Rostom, Yosry
    Rashed, Yaser
    NEUROSURGICAL REVIEW, 2011, 34 (01) : 87 - 96
  • [30] Linear accelerator-based stereotactic radiosurgery of intracranial meningiomas: results of the first 5 years of clinical practice
    Osama S. Abdelaziz
    Alaa Kandil
    Shaaban El-Assaal
    Amro Abdelaziz
    Yosry Rostom
    Yaser Rashed
    Neurosurgical Review, 2011, 34 : 87 - 99