Grid Harmonics Suppression for Three Phase Dual-Frequency Grid-Connected Inverter Based on Feedforward Compensation

被引:0
|
作者
Chen, Zhigang [1 ,2 ]
Ma, Dongkai [2 ]
Yang, Liyong [2 ]
Liu, Shuo [2 ]
Tong, Chaonan [1 ]
Zhao, Yifan [2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Automat & Elect Engn, Beijing 100083, Peoples R China
[2] North China Univ Technol, Coll Elect & Control Engn, Beijing 100144, Peoples R China
来源
SYMMETRY-BASEL | 2023年 / 15卷 / 08期
关键词
three-phase grid-connected inverter; current ripple; power quality; LCL-FILTER; CONTROL STRATEGY; CONTROL SCHEME; DESIGN; TOPOLOGY;
D O I
10.3390/sym15081517
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Using a low pulse ratio, the electromagnetic interference and switching loss of an inverter can be effectively reduced, particularly in high-power applications. However, due to variations in grid impedance, it is a challenging task to achieve stable operation of an LCL-type grid-connected inverter (GCI) using the active damping method with low pulse ratio. Thus, a novel three-phase dual-frequency GCI is presented to ensure the symmetry of the output power and the stable operation of the system address stability issues. The proposed inverter topology in this article is composed of two inverters in parallel, which are, respectively, a power inverter unit (PIU) and an auxiliary harmonic elimination unit (AHEU). To reduce the switching loss and improve the inverter efficiency, the switching frequency of the PIU is relatively low, injecting current into the grid. Moreover, the feedforward compensation method is used in AHEU. AHEU operates at high switching frequency to generate a current component that is symmetrical with the ripple com-ponent, improving the power quality, without extracting the current harmonic as the current reference. The operating principle of feedforward compensation is explained, and a proper parameter design procedure is presented in this paper. Since L filters are used for the proposed inverter, the system can operate stably where the ratio of switching frequency to fundamental frequency is low. A 10 kW laboratory prototype was built. The experimental results showed that the grid current ripple could be effectively eliminated and the THD of the grid current was 3.01%. The proposed inverter has good stability in a weak grid, and the efficiency of the proposed inverter is 95.98% at rated current, which is 0.81% higher than the traditional GCI, effectively increasing the efficiency of the system.
引用
收藏
页数:18
相关论文
共 50 条
  • [11] Robustness and Harmonics Suppression of Grid-Connected Inverters with Different Grid Voltage Feedforward Compensations in Weak Grid
    Hu, Yuan
    Xu, Jinming
    Qian, Hao
    Bian, Shenyiyang
    Xie, Shaojun
    2020 IEEE 29TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2020, : 779 - 784
  • [12] Harmonics Compensation for Grid-Connected Inverter Caused by Local Nonlinear Load
    Shin, Chanho
    Lim, Kyungbae
    Petrus, Simatupang Desmon
    Choi, Jaeho
    2017 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL DRIVES AND POWER ELECTRONICS (EDPE), 2017, : 46 - 52
  • [13] Robust Predictive Current Control of a Grid-Connected Inverter with Harmonics Compensation
    Heo, Hye-Seong
    Choe, Gyu-Ha
    Mok, Hyung-Soo
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 2212 - 2217
  • [14] Analysis of a hybrid controlled three-phase grid-connected inverter with harmonics compensation in synchronous reference frame
    Sha, D.
    Wu, D.
    Liao, X.
    IET POWER ELECTRONICS, 2011, 4 (07) : 743 - 751
  • [15] A Feedforward Compensation Based Decoupling Control Strategy for Grid-Connected Inverter with LCL Filter
    Qu, K.
    Ye, T.
    Zhao, J.
    Chen, X.
    2015 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE-ECCE ASIA), 2015, : 2463 - 2468
  • [16] Resonant frequency offset suppression strategy of LCL grid-connected inverter using capacitor voltage feedforward in weak grid
    Yang M.
    Yang J.
    Zhao T.-Y.
    Zheng C.
    Wei Y.-F.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2022, 26 (04): : 107 - 120
  • [17] A Full-Feedforward Scheme of Grid Voltages for a Three-Phase Grid-Connected Inverter With an LCL Filter
    Li, Weiwei
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 96 - 103
  • [18] Photovoltaic Grid-connected Inverter Harmonic Compensation and Grid-connected Unified Control
    Xu Jin
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 696 - 699
  • [19] Power Controller Effects for Mitigating Harmonics in a Three-Phase Grid-Connected Inverter
    Ismail, F.
    Jamaludin, J.
    Rahim, N. A.
    IEACON 2021: 2021 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE (IEACON), 2021, : 151 - 156
  • [20] Passivity-Based Stabilization of a Grid-Connected Three-Phase Inverter System with Feedforward Control
    Kato T.
    Inoue K.
    Yamamoto Y.
    Yomura K.
    IEEJ Transactions on Electronics, Information and Systems, 2020, 140 (11) : 1189 - 1197